US$339.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 0669-2011: Determination of gentamycin residues in meats and meat products for export. Cylinder plate method Status: Valid SN/T 0669: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| SN/T 0669-2011 | English | 339 |
Add to Cart
|
3 days [Need to translate]
|
Determination of gentamycin residues in meats and meat products for export. Cylinder plate method
| Valid |
SN/T 0669-2011
|
| SN 0669-1997 | English | 679 |
Add to Cart
|
5 days [Need to translate]
|
Method for the determination of gentamycin redidues in meats and meat products for export. Cylinder plate method
| Obsolete |
SN 0669-1997
|
PDF similar to SN/T 0669-2011
Basic data | Standard ID | SN/T 0669-2011 (SN/T0669-2011) | | Description (Translated English) | Determination of gentamycin residues in meats and meat products for export. Cylinder plate method | | Sector / Industry | Commodity Inspection Standard (Recommended) | | Classification of Chinese Standard | X22 | | Word Count Estimation | 13,151 | | Date of Issue | 2011-02-25 | | Date of Implementation | 2011-07-01 | | Older Standard (superseded by this standard) | SN 0669-1997 | | Quoted Standard | GB/T 6682 | | Regulation (derived from) | National-Quality-Inspection-accreditation (2011) 90 | | Issuing agency(ies) | General Administration of Customs | | Summary | This standard specifies the method Beidie export meat and meat products gentamicin residue detection. This standard applies to exports of chicken meat in gentamicin residue screening test, a positive result of applying other methods to confirm. |
SN/T 0669-2011: Determination of gentamycin residues in meats and meat products for export. Cylinder plate method ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of gentamycin residues in meats and meat products for export. Cylinder plate method
People's Republic of China Entry-Exit Inspection and Quarantine Standards
Replacing SN 0669-1997
The residue detection method export meat and meat products gentamicin
Plate method
Issued on. 2011-02-25
2011-07-01 implementation
People's Republic of China
The State Administration of Quality Supervision, Inspection and Quarantine released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard replaces SN 0669-1997 "export of meat and meat products gentamicin residues in plate method."
This standard compared with SN 0669-1997, the main technical changes are as follows.
--- Original standard was changed from quantitative detection method for the qualitative detection methods;
--- The original standard name "export meat and meat products gentamicin residues in plate method" to "export meat and meat
The product residue detection method gentamicin plate method ";
--- Re-verification of the original standard low detection limits by 0.1mg/kg amended to 0.05mg/kg.
This standard is proposed and managed by the National Certification and Accreditation Administration Committee.
This standard was drafted. People's Republic of China Shandong Exit Inspection and Quarantine, China Ocean University.
The main drafters of this standard. LIU Yun-guo, LIN, handsome Liu, Jia Juntao, Ray quality paper, Lin Liming, Li Zhengyi, Ma Weixing, Tang Jing, Zhang Jian,
Room Bao Hai, Zhu Suzhen, Zhao Liqing, Jiang Yinghui, Ma, Han Qing, Lee Ming, Yan Xianhui.
This standard replaces the standards previously issued as follows.
--- SN 0669-1997.
The residue detection method export meat and meat products gentamicin
Plate method
1 Scope
This standard specifies the method for exporting meat and Saucer gentamicin residues in meat products.
This standard is applicable to the export of gentamicin residues in chicken screening test, the positive results of the application of other methods to confirm.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
Laboratory use specifications and test methods GB/T 6682 Analysis
3 Sample Preparation and Storage
3.1 Sample Preparation
The representative sample of the edible parts into minced minced machine. Mix well with a quartering reduced to less than 500g, as the test
kind. Load a clean container, after sealing, and labeled. In the sample preparation procedure, it should prevent sample contamination or the occurrence of residues containing
Variation.
3.2 Sample preservation
The sample was stored frozen at -18 ℃ below.
Principle 4
Buffer (pH8.0 ± 0.1) to extract a sample of gentamicin residue with phosphate, after centrifugation, the supernatant as sample solution to the epidermis
Staphylococcus aureus (Staphylococcusepidermidis) as the indicator bacteria were detected by plate method.
5. Apparatus
5.1 dish. diameter 90mm, bottom smooth glass or plastic dish pan, cover with ceramic tile or glass cover embedded dry filter paper.
5.2 Oxford Cup. stainless steel cylinder, an outer diameter of 8.0mm ± 0.1mm, an inner diameter of 6.0mm ± 0.1mm, high 10.0mm ± 0.1mm.
5.3 g's bottle. 800mL.
5.4 vernier caliper. Measuring range 0mm ~ 200mm, precision 0.02mm.
5.5 homogenizer. speed of not less than 8000r/min.
5.6 centrifuge. speed of not less than 4000r/min.
5.7 temperature water bath. 0 ℃ ~ 100 ℃, accuracy of ± 1 ℃.
5.8 incubator. 36 ℃ ± 1 ℃, shelf should be level.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 0669-2011_English be delivered?Answer: Upon your order, we will start to translate SN/T 0669-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of SN/T 0669-2011_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 0669-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version SN/T 0669-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version SN/T 0669-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|