US$279.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. NB/T 10279-2019: (Power transmission and transformation equipment) Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| NB/T 10279-2019 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
(Power transmission and transformation equipment)
| Valid |
NB/T 10279-2019
|
PDF similar to NB/T 10279-2019
Basic data | Standard ID | NB/T 10279-2019 (NB/T10279-2019) | | Description (Translated English) | (Power transmission and transformation equipment) | | Sector / Industry | Energy Industry Standard (Recommended) | | Classification of Chinese Standard | K40 | | Classification of International Standard | 29.020 | | Word Count Estimation | 12,146 | | Date of Issue | 2019-11-04 | | Date of Implementation | 2020-05-01 | | Issuing agency(ies) | National Energy Administration |
NB/T 10279-2019: (Power transmission and transformation equipment)---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Power transmission and transformation equipments-Warm-damp environmental
ICS 19.040
K 40
NB
Energy Industry Standards of the People's Republic of China
Humid and hot environmental conditions for power transmission and transformation equipment
conditions
2019-11-04 released
2020-05-01 implementation
Issued by National Energy Administration
Table of contents
Foreword...II
1 Scope...1
2 Normative references...1
3 Description of environmental parameters and their codes...1
4 Hot and humid environmental conditions...2
4.1 General requirements...2
4.2 Climatic conditions...2
4.3 Biological conditions...3
4.4 Conditions for chemically active substances...3
4.5 Mechanically active material conditions...4
4.6 Mechanical conditions...4
4.7 Electromagnetic conditions...5
Appendix A (informative appendix) Description of the application of environmental conditions...7
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009 "Guidelines for Standardization Work Part 1.Standard Structure and Compilation".
This standard was proposed by China Electrical Equipment Industry Association.
This standard is under the jurisdiction of the National Standardization Technical Committee for Environmental Conditions and Environmental Testing of Electrical and Electronic Products (SAC/TC 8).
Drafting organizations of this standard. China National Electrical Equipment Research Institute Co., Ltd., Shenzhen Graduate School of Tsinghua University, Guangzhou Power Supply Bureau Co., Ltd.
Force Testing Research Institute, Shenzhen Uruit Testing Technology Co., Ltd., Shenzhen Metrology and Quality Testing Research Institute, China Shipbuilding Industry Corporation
The 704th Research Institute, Fujian Xinneng Offshore Wind Power R&D Center Co., Ltd., Hainan Power Grid Co., Ltd. Electric Power Research Institute, Guangzhou
Baiyun Electrical Equipment Co., Ltd., Global Energy Internet Research Institute Co., Ltd., Hainan Electric Power School, Guangdong Power Grid Co., Ltd.
The company's Electric Power Research Institute, Wuxi Sunan Test Equipment Co., Ltd., Xiangjiaba Hydropower Plant.
The main drafters of this standard. Wang Jun, Jie Ganxin, Wang Xilin, Wang Yong, Fan Weinan, Xu Xuedong, Mei Liguang, Zhan Yang, Qian Zhaojun,
Tu Chuankui, Zhao Hailong, He Zhou, Hao Wenkui, Liu Guoqing, Huang Feng, Ni Yangyi, Yi Yawen, Chen Chuan, Zhang Wenqiang, Liu Xin, Jia Zhidong, Tan
Yu, Cheng Zishuo, Liu Xiaoping, Huang Song, Wang Xun, Liang Yongchun, Zhang Qijun.
Humid and hot environmental conditions for power transmission and transformation equipment
1 Scope
This standard specifies the environmental parameter level and severity of the power transmission and transformation equipment during service under humid and hot environmental conditions.
This standard is applicable to the power transmission and transformation equipment used in the two climate types of “damp heat” and “sub-humid heat” specified in GB/T 4797.1-2018.
Prepared.
Note. Considering the actual environmental conditions used in power transmission and transformation, this standard does not include marine environmental conditions, that is, hydrological conditions are not considered. But it contains hot and humid island environment.
This standard only specifies the environmental conditions that directly affect the product, but does not describe the specific impact of these environmental conditions on the product.
The environmental conditions described in this standard do not include storage, transportation and installation. For such conditions, see relevant standards and technical specifications.
This standard does not consider environmental conditions caused by fire, blasting and ionizing radiation and environmental conditions caused by other accidents. In special circumstances
Under circumstances, the probability of occurrence of these factors should be considered.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
GB/T 4796-2017 Environmental conditions classification environmental parameters and their severity
GB/T 4797.1-2018 Classification of Environmental Conditions Natural Environmental Conditions Temperature and Humidity
GB/T 4798.10-2006 Introduction to Environmental Conditions for Application of Electrical and Electronic Products
GB/T 14091-2009 Mechanical product environmental parameter classification and its severity classification
GB/Z 18039.1-2000 Electromagnetic compatibility environment Electromagnetic environment classification
3 Description of environmental parameters and codes
For detailed classification and application guidelines of environmental condition parameters, see GB/T 4796-2017 and GB/T 4798.10-2006.
4 Humid and hot environmental conditions
4.1 General requirements
4.1.1 The actual use of power transmission and transformation equipment will be affected by a variety of environmental conditions. The conditions and codes included in it are climatic conditions (K),
Special climatic conditions (Z), biological conditions (B), chemically active material conditions (C), mechanically active material conditions (S), mechanical conditions (M)
And electromagnetic conditions (E). For equipment in different places of use in different hot and humid areas, the above-mentioned various influential conditions and their strict
Cool degree.
4.1.2 For some parameters in the standard, the severity cannot be specified quantitatively, but the severity is qualitatively specified for typical parameters, such as
Condensation, icing and frost in climatic conditions, biological conditions, etc.
4.2 Climatic conditions
4.2.1 Climatic conditions grade parameters, see Table 1.
Note. Zh. means heat radiation conditions; Za. means ambient air movement conditions; Zw. means other water source conditions except rain.
4.3 Biological conditions
The biological conditions in this standard only give typical parameters, and do not give quantitative severity values. See Table 3 for biological condition level parameters.
4.4 Conditions for chemically active substances
See Table 4 for the condition level of chemically active substances.
4.5 Mechanically active material conditions
The environmental parameters of mechanically active material conditions are shown in Table 5.
Table 5 Condition level parameter value of mechanical active material
4.6 Mechanical conditions
Refer to Table 6 for the mechanical environmental condition parameter levels of vibration and swing, and refer to GB/T for specific spectrum types and response spectra.
4796-2017 and GB/T 14091-2009.
4.7 Electromagnetic conditions
See Table 7 and Table 8 for the electromagnetic environmental conditions and power supply conditions of the power transmission and transformation equipment. Sources of radiated pulse disturbances and
Refer to GB/Z 18039.1-2002 for the range of harassment.
AA
Appendix A
(Informative appendix)
Description of environmental condition level application
A.1 Description
This appendix provides necessary supplementary explanations on how to correctly select environmental parameters and their levels.
The climatic condition parameters in the standard refer to the short-term extreme conditions experienced by the transmission and transformation equipment in the service process.
The multi-year average of the extreme value, the chemical active substance condition adopts the maximum value, that is, the limit value or peak value that does not exceed 30 minutes per day.
A.2 Climatic conditions
3K4.This level is suitable for temperature controlled places with large humidity changes, and humidity control is not adopted. The product may encounter condensation and rain
The impact of other water sources. But it is not affected by natural precipitation and freezing.
3K5, 3K5L. This grade is suitable for places where there is neither temperature control nor humidity control. Products can be exposed to solar radiation and heat radiation
It is affected by sunlight, air flow, condensation, and water other than rain, and may encounter freezing, but is not affected by natural precipitation.
3K5L differs from 3K5 only in "high temperature" conditions.
4K3Hs. This level is suitable for products directly exposed to "damp heat" and "sub-humid heat" climate types without weather protection.
A.3 Biological conditions
3B1.This level is suitable for places where there is no biological hazard. The product is required to take protective measures, or the product is basically free of mold growth and
Use in places destroyed by animals.
3B2, 4B1.These two levels are suitable for products exposed to mold growth and rodent damage, but no termites.
4B2.This level applies to places where the product is exposed to mold growth and rodents (including termites) damage.
4B3, 4B4.These two levels are applicable to places affected and damaged by marine organisms, and are determined according to the actual conditions in each sea area.
A.4 Chemically active substance conditions
3C1, 4C1.These two levels are suitable for places with less chemically active substances.
3C2, 4C2.These two levels are suitable for general pollution, low chemical gas concentration in the environment, but sometimes people can smell pungent odor
Place.
3Cs1, 4Cs1.These two grades are suitable for areas far away from the ocean, and are basically free from salt spray pollution and corrosion.
3Cs2, 4Cs2.These two grades are suitable for products that are usually used alternately between salty atmosphere and dry atmosphere.
3Cs3, 4Cs3.These two levels are suitable for use in the marine environment or in offshore areas, which may be frequently exposed to the marine environment, but are usually sealed
Closed object protection products.
3Cs4, 4Cs4.These two levels are suitable for products exposed to this environment during most of their service life in the marine environment or offshore areas.
Product.
A.5 Mechanically active material conditions
3S1.This level is suitable for places where measures are taken to minimize floating dust and prevent sand from entering.
3S2.This level is suitable for places without dust-proof facilities, but the place is not close to sand and dust sources.
3S3.This level is suitable for places close to sand, dust or industrial dust sources or geographically located in places with windy sand or dust in the air.
4S1.This level is suitable for places not close to the source of sand.
4S2.This level is suitable for places with sand, dust or industrial dust sources.
4S3.This level is suitable for places with sand, dust or industrial dust sources or geographical locations with windy sand or dust in the air.
A.6 Mechanical conditions
M1.This level is suitable for places without significant vibration and impact, for example, away from places where there are moving or rotating machinery.
M2.This level is suitable for places with low significant vibrations, such as vibrations from nearby passing vehicles.
M3.This level is suitable for places with low significant impact, such as impacts from nearby passing vehicles or waves crashing.
M4.This level is suitable for places with significant vibration and impact, such as vibration and impact from nearby passing vehicles or relatively large waves
Slap etc.
M5.This level is suitable for places with high impact, for example, the product is installed near moving or rotating machinery.
M6.This level is suitable for places with high vibration, for example, the product is installed near a moving or rotating machine with high vibration.
M7.This level is suitable for places with great vibration, for example, the product is directly installed on moving or rotating machinery.
M8.This level is suitable for places with extreme vibration, for example, the product is directly installed on a movable or rotating machine with high vibration.
A.7 Electromagnetic conditions
E1.This level is suitable for electromagnetic radiation environments with good protection measures or low energy levels.
E2.This level is suitable for electromagnetic environments with general protective measures or at a medium energy level.
E3.This level is suitable for electromagnetic radiation environment without protective measures or at high energy levels.
E4.This level is suitable for extremely harsh electromagnetic environments.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of NB/T 10279-2019_English be delivered?Answer: Upon your order, we will start to translate NB/T 10279-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of NB/T 10279-2019_English with my colleagues?Answer: Yes. The purchased PDF of NB/T 10279-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|