HOME   Cart(1)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

NB/T 42107-2017 PDF English

US$410.00 · In stock · Download in 9 seconds
NB/T 42107-2017: High-voltage direct current circuit-breaker
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
NB/T 42107-2017English410 Add to Cart 0-9 seconds. Auto-delivery High-voltage direct current circuit-breaker Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: NB/T 42107-2017
      

Similar standards

GB/T 38328   GB/T 30092   NB/T 11077   

NB/T 42107-2017: High-voltage direct current circuit-breaker

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/NBT42107-2017
NB ENERGY INDUSTRY STANDARD ICS 29.120.40 K 43 Filing No.. 59884-2017 High-voltage direct current circuit-breaker Issued on: AUGUST 02, 2017 Implemented on: DECEMBER 01, 2017 Issued by. National Energy Administration

Table of Contents

Foreword... 4 Introduction... 5 1 Scope... 6 2 Normative references... 6 3 Terms and definitions... 7 4 Normal and special use conditions... 11 5 Rated value... 11 5.1 Rated DC voltage... 11 5.2 Rated current... 12 5.3 Rated short-circuit current... 12 5.4 Rated interrupting current... 12 5.5 Maximum continuous operating current... 12 5.6 Insulation level... 12 5.7 Number of mechanical operations... 13 5.8 Number of breakings of rated interrupting current... 13 5.9 Rated power consumption... 13 5.10 Rated energy absorption... 13 5.11 Rated auxiliary and control circuit power supply voltage... 14 6 Structure and performance requirements... 14 6.1 Overview... 14 6.2 General requirements... 14 6.3 Terminal mechanical load... 14 6.4 Creepage distance... 15 6.5 Auxiliary and control equipment... 15 6.6 Power operation... 15 6.7 Degree of protection of enclosure... 15 6.8 Nameplate... 15 6.9 Electromagnetic compatibility (EMC)... 16 7 Type test... 16 7.1 General... 16 7.2 Insulation test... 16 7.3 Measurement of main circuit resistance... 16 7.4 Temperature rise test... 16 7.5 Verification of degree of protection... 17 7.6 Sealing test... 17 7.7 Electromagnetic compatibility test (EMC)... 17 7.8 Mechanical operation test at ambient air temperature... 17 7.9 Terminal static load test... 17 7.10 Breaking test of DC circuit-breaker... 17 7.11 Seismic test... 19 8 Exit-factory test... 19 8.1 Overview... 19 8.2 Exit-factory test of the whole machine (when applicable)... 19 8.3 Measurement of main circuit resistance... 19 8.4 Design and appearance inspection... 19 9 Special test... 20 10 Field test... 20 11 Rules for transportation, storage, installation, operation, maintenance... 20 11.1 Overview... 20 11.2 Conditions for transportation, storage, installation... 20 11.3 Installation... 20 11.4 Operation... 20 11.5 Maintenance... 21 12 Safety... 22 13 Impact of the product on environment... 22 Appendix A (Informative) Guidelines for the selection of DC circuit-breakers... 23 Appendix B (Informative) Overload current of DC transmission system... 25 Appendix C (Informative) DC circuit-breaker test circuit and test current waveform 26 References... 30 High-voltage direct current circuit-breaker

1 Scope

This standard applies to high-voltage DC circuit-breakers (hereinafter referred to as DC circuit-breakers) for DC 6 kV and above power systems. This standard is mainly for mechanical DC circuit-breakers. Power electronic and hybrid DC circuit-breakers can also refer to this standard. This standard specifies the operating environment conditions, terms and definitions, ratings, technical requirements, type tests, exit-factory tests, special tests, field tests, etc. of DC circuit-breakers. This standard also applies to the operating mechanism of DC circuit-breakers and their auxiliary equipment. Note. This standard covers lightning arresters, capacitors, reactors and other devices used in DC circuit-breakers.

2 Normative references

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) is applicable to this standard. GB/T 1094.6-2011 Power transformers - Part 6.Reactors GB 1984-2014 High-voltage alternating-current circuit-breakers GB/T 2900.20-2016 Electrotechnical terminology - High-voltage switchgear and controlgear GB/T 11022-2011 Common specifications for high-voltage switchgear and controlgear standards GB/T 13498-2017 Terminology for high-voltage direct current (HVDC) transmission GB/T 13540 Seismic qualification for high voltage switchgear and controlgear Note. Where there are special requirements for DC voltage, it shall be determined by negotiation between the supplier and the buyer. 5.2 Rated current It shall comply with the provisions of 4.5.1 of GB/T 11022-2011. 5.3 Rated short-circuit current The DC current expected to be interrupted by the DC circuit-breaker is selected from the following values (kA). 2, 5, 8, 10, 12.5, 16, 20, 25, 31.5, 40, 50, 63, 80, 100, 125. Note. Where there are special requirements for current, it shall be determined by negotiation between the supplier and the buyer. 5.4 Rated interrupting current The DC current interrupted by the DC circuit-breaker is selected from the following values (kA). 4, 5, 6.3, 8, 10, 12.5, 16, 20, 25, 31.5. Note. Where there are special requirements for the current, it shall be determined by negotiation between the supplier and the buyer. 5.5 Maximum continuous operating current The maximum continuous operating current is generally 1.05 ~ 1.25 times the rated current. 5.6 Insulation level The rated insulation level of the DC circuit-breaker shall be selected from the values given in Table 1. 5.11 Rated auxiliary and control circuit power supply voltage Complies with the provisions of 4.9 of GB/T 11022-2011.

6 Structure and performance requirements

6.1 Overview In DC systems, DC circuit-breakers often use several parallel branches to complete the breaking task. Generally, DC circuit-breakers are composed of three parts. a) Low-resistance on-state current conducting branch; b) High-resistance current limiting and commutation branch during the breaking process; c) Energy absorption branch. For the mechanical, power electronic, hybrid DC circuit-breakers described in this standard, each has different topological structures and different technical characteristics. The general topological structures of these three DC circuit-breakers are described in Appendix A. 6.2 General requirements DC circuit-breakers shall be equipped with open and closed status indicators; their installation locations shall be clearly visible and reliable. All components of DC circuit-breakers shall be corrosion-resistant or undergo corrosion-resistant treatment. 6.3 Terminal mechanical load The mechanical load of the wiring terminals in DC circuit-breakers shall not be less than. - Horizontal longitudinal. 2000 N; - Horizontal transverse. 1500 N; - Vertical. 1500 N. Note 1.See 6.2.3 of GB/T 25309-2010. Note 2.The wiring load under different voltage levels shall meet the requirements of actual working conditions. 6.4 Creepage distance It shall be in accordance with actual engineering requirements. 6.5 Auxiliary and control equipment Comply with the provisions of 5.4 of GB/T 11022-2011 and make the following supplement. For DC circuit-breakers using forced air cooling or water cooling, the relevant requirements of control equipment shall be considered. 6.6 Power operation Comply with the provisions of 5.5 of GB/T 11022-2011. 6.7 Degree of protection of enclosure Comply with the provisions of 5.13 of GB/T 11022-2011 and make the following supplement. The degree of protection of enclosure shall not be less than IP23. 6.8 Nameplate The technical parameters on the nameplate shall at least include the following parameters. - Rated DC voltage; - Rated current; - Rated power consumption. - Rated short-circuit current (optional); - Maximum continuous operating current; - Rated lightning impulse withstand voltage; - Rated DC withstand voltage; - Rated interruption current; 7.5 Verification of degree of protection Conform to the provisions of 6.7 of GB/T 11022-2011. 7.6 Sealing test Conform to the provisions of 6.8 of GB/T 11022-2011 (when applicable). 7.7 Electromagnetic compatibility test (EMC) Conform to the provisions of 6.9 of GB/T 11022-2011. 7.8 Mechanical operation test at ambient air temperature Conform to the provisions of 6.101.2 of GB 1984-2014 and make the following supplement. Only mechanical operation test is carried out on mechanical disconnecting device. 7.9 Terminal static load test The terminal force shall meet the requirements of 6.3.The test shall be carried out in accordance with the requirements of 6.101.6 of GB 1984-2014. 7.10 Breaking test of DC circuit-breaker 7.10.1 Overview The purpose of this test is to verify whether the DC circuit-breaker has the ability to break the specified DC short-circuit current. This test verifies that the DC circuit-breaker can successfully interrupt the DC current within the rated short-circuit current range, and that the interrupter can withstand the recovery voltage between the breaks. According to the actual project requirements, the test circuit shall be equivalent to the actual operating conditions of this type of DC circuit-breaker. The interruption test shall at least include the following requirements. a) Recommended tests for products above 10 kV, see Table 2;

9 Special test

Performed in accordance with the agreement between the manufacturer and the user.

10 Field test

The purpose of the field test is to check whether the DC circuit-breaker and its auxiliary equipment are not damaged due to transportation and storage, and to verify the overall performance of the assembled DC circuit-breaker. The field test includes the inspection and testing of the DC circuit-breaker components and the DC circuit-breaker as a whole. Each component is implemented in accordance with its own standards. The test methods and requirements are negotiated by the supplier and the buyer.

11 Rules for transportation, storage, installation, operation,

maintenance 11.1 Overview Comply with the provisions of Chapter 10 of GB/T 11022-2011. 11.2 Conditions for transportation, storage, installation Comply with the provisions of 10.1 of GB/T 11022-2011. 11.3 Installation Comply with the provisions of 10.2.1 ~ 10.2.4 of GB/T 11022-2011. 11.4 Operation The instructions provided by the manufacturer shall include the following information. - General description of the equipment, with particular attention to its characteristics and technical description of operation, so that the user fully understands the main principles involved; - Description of the safety performance of the equipment; - Description of the actions taken to operate, isolate, ground, maintain, test the equipment related to operation. 11.5 Maintenance 11.5.1 Overview The effectiveness of maintenance depends mainly on the content of the instructions written by the manufacturer and the extent to which the user implements the instructions. 11.5.2 Recommendations for manufacturers The manufacturer shall provide a maintenance manual that includes the following information. - Scope and frequency of maintenance. - Detailed description of maintenance work; - A complete set of drawings of switchgear and controlgear details that are critical to maintenance, with clear markings of general assembly, subassembly, important parts on the drawings; - Limit values and allowable deviations; if there are deviations, make necessary corrections; - Specifications of auxiliary maintenance materials, including warnings for known incompatible materials; - List of special tools, lifting and maintenance equipment. - Test items after maintenance; - Recommended spare parts (description, code, quantity) and storage recommendations; - Estimates of effective planned maintenance time; - At the end of the operating life of the equipment, how to deal with the equipment, including environmental requirements. 11.5.3 Recommendations for users If the user wishes to perform maintenance by himself, his staff shall have a detailed understanding of the corresponding switchgear and controlgear.

Appendix A

(Informative) Guidelines for the selection of DC circuit-breakers A.1 Overview This Appendix applies to DC circuit-breakers for DC transmission with voltage levels of 6 kV and above. The recommended values of the rated parameters of DC circuit- breakers are as shown in Chapter 5 of this standard. In order to make the DC circuit-breaker suitable for the specified operating task, it shall be selected according to the various rated values required by the load conditions and fault conditions. A.2 Selection of DC circuit-breaker ratings A.2.1 Selection of rated DC voltage The rated DC voltage of the DC circuit-breaker can be selected from 5.1. A.2.2 Selection of rated current The rated operating current of the DC circuit-breaker is determined by the rated current of the DC project. The rated current of the DC circuit-breaker can be selected from 5.2. A.3 Selection of DC circuit-breaker type The typical schemes of DC circuit-breakers are. mechanical, power electronic, hybrid. a) Mechanical DC circuit-breakers are generally composed of breaking device (CB), commutation capacitor (C), commutation reactor (L), commutation switch (G), lightning arrester (MOV), as shown in the dotted box in Figure A.1; b) Power electronic DC circuit-breakers are generally composed of power electronic components (S) and lightning arrester (MOV), as shown in the dotted box in Figure A.2; c) Hybrid DC circuit-breakers are generally composed of fast mechanical disconnector (FD), auxiliary DC switch (FS), main DC switch (MS), lightning arrester (MOV), among which the main DC switch and auxiliary DC switch are both power electronic components. As shown in the dotted box in Figure A.3. DB1 and DB2 in Figures A.1, A.2, A.3 are auxiliary isolation devices used to interrupt residual current. ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of NB/T 42107-2017 be delivered?

Answer: The full copy PDF of English version of NB/T 42107-2017 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of NB/T 42107-2017_English with my colleagues?

Answer: Yes. The purchased PDF of NB/T 42107-2017_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- NB/T 42107-2017 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of NB/T 42107-2017?

A step-by-step guide to download PDF of NB/T 42107-2017_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "NB/T 42107-2017".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9