Verification Regulation of Pupil Distance Meters
| Valid |
JJG 952-2014
|
| JJG 952-2000 | English | 479 |
Add to Cart
|
4 days [Need to translate]
|
Verification Regulation of Pupil Distance Meters
| Obsolete |
JJG 952-2000
|
PDF similar to JJG 952-2014
Basic data | Standard ID | JJG 952-2014 (JJG952-2014) | | Description (Translated English) | Verification Regulation of Pupil Distance Meters | | Sector / Industry | Metrology & Measurement Industry Standard | | Classification of Chinese Standard | A52 | | Classification of International Standard | 17.040 | | Word Count Estimation | 18,133 | | Date of Issue | 6/15/2014 | | Date of Implementation | 12/15/2014 | | Older Standard (superseded by this standard) | JJG 952-2000 | | Quoted Standard | JJF 1059.1-2012; GB/T 26397-2011 | | Regulation (derived from) | The State Administration of Quality Supervision, Inspection and Quarantine Notice No. 64 of 2014 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | | Summary | This Standard specifies the Centrometer initial verification, verification and subsequent use of checks. |
JJG 952-2014: Verification Regulation of Pupil Distance Meters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Pupil Distance Meters
State verification procedures People's Republic of China
Centrometer
Issued on. 2014-06-15
2014-12-15 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Centrometer verification procedures
ofPup
Replacing JJG 952-2000
Focal point. the National Technical Committee on Medical Measurement
The main drafting units. China Institute of Metrology
Participated in the drafting unit. Hangzhou quality technical supervision detection hospital
This procedure entrust the National Technical Committee is responsible for interpreting medical measurement
The main drafters of this procedure.
Sun Jie (China Institute of Metrology)
Hu Zhixiong (China Institute of Metrology)
Drafters participate.
Zhu Jianping (China Institute of Metrology)
Xu Congen (Hangzhou Quality and Technical Supervision and Inspection Institute)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 Terms (1)
3.1 IPD (1)
3.2 Basic eye position (1)
3.3 monocular pupillary distance (1)
3.4 Centrometer (1)
4 Overview (1)
5 metering performance requirements (2)
5.1 IPD indication error (2)
5.2 asymmetry error (2)
5.3 rounding error (2)
6 General Requirements (2)
6.1 appearance requirements (2)
6.2 illumination uniformity (3)
6.3 Measurement Capability (3)
7 control of measuring instruments (3)
7.1 test conditions (3)
7.2 Verification Project (3)
7.3 Verification Methods (3)
7.4 test results processing (4)
7.5 test cycle (4)
Appendix A Centrometer original records (recommended format) (5)
Appendix B Centrometer calibration certificate/test results notice (inside) (recommended format) (6)
C Appendix Centrometer standard calibration device (9)
Appendix D IPD IPD instrument indication error test results Measurement Uncertainty Example (10)
Introduction
The procedures in place JJG 952-2000 "Centrometer." This procedure is based on the JJG 952-2000 reference
JJF1002-2010 "national verification procedures write rules", GB/T 26397-2011 "light academic ophthalmology
The term "revised.
Compared with JJG 952-2000 "Centrometer", except in accordance with JJF1002-2010 "national verification procedures compiled
Write Rules "section made of the composition and modify the formatting on the outside, the main technical changes are as follows.
--- Increasing the reference document (see 2);
--- Increasing the term (see 3);
--- Modify an overview of some of the text representation (see 4);
--- IPD revised the measurement range requirements (see 6.3.2);
--- Adds rounding error applies Centrometer description (see 7.3.2.3);
--- Revised as close to the theoretical value of the IPD IPD as far obtained (see 7.3.2.3);
--- Modify the test results processing textual representation (see 7.4);
--- Modify the test records recommended format (see Appendix A);
--- Modified Centrometer test certificate (in-page) format, an increase of illumination uniformity (see Appendix B);
--- Increased Centrometer standard calibration device related content (see Appendix C);
--- Increased Centrometer IPD indication error test results Measurement Uncertainty Example (see Appendix D);
--- Adjustment Appendix order.
The previous regulations published case.
--- JJG 952-2000.
Centrometer verification procedures
1 Scope
The order applies to Centrometer initial verification, use and subsequent verification check.
2. References
This procedure refers to the following documents.
JJF1059.1-2012 Evaluation and Expression of Uncertainty in Measurement
GB/T 26397-2011 Ophthalmic optics terminology
For dated references, only the dated edition applies to this procedure; undated reference documents
Member, the latest edition (including any amendments) applies to this procedure.
3 Terms
3.1 IPD interpupilarydistance
Eyes flat as the front of the goal of infinity, the distance between the centers of two pupils.
3.2 Basic eye position primaryposition
Human eye level in front of the goal, the relative position of the head of the human eye for.
3.3 Unilateral IPD monocularpupilarydistance
In the basic eye position, the pupil center and the bridge of the nose or frames from the midline of the human eye.
3.4 Centrometer pupildistancemeter
In the process of optometry for a method of measuring the distance between the eyes of two instruments Pupillometry people.
4 Overview
Centrometer is an instrument used to measure the human eye pupil distance.
Centrometer mainly composed of four parts raster display and control systems, optical systems, electromechanical systems and software, etc.,
With IPD, unilateral IPD IPD and different working distance measurement function, is a light, mechanical, electrical integration
instrument.
IPD instrument measuring principle. illuminated by the light source as the standard by the imaging optical system in front of a particular test personnel
Work at a distance, when the measured person watching as the standard, the left and right eye visual axis intersect at this particular working distance.
In this case the measured light on people around the cornea to form a reflective surface of each point. Optometrist can look through the eyepiece at the same time
To reading gossamer and two reflex points, moving left and right, respectively aligned with gossamer reading test after officers left and right eye reflex points,
It can get tested IPD officers on the display.
According to the principle of optometry, measuring just far Centrometer measured IPD staff in recent IPD can be obtained by conversion. I.e.
Infinity measured after work gear away IPD test personnel to choose the right near working distance measured according to the situation of persons
Off and transferred to the corresponding work gear, reading on the display at this time is to test the staff in the near working distance
Near IPD. In practice, the situation should be based on the measured nearly IPD personnel and reference data and real Centrometer
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 952-2014_English be delivered?Answer: Upon your order, we will start to translate JJG 952-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 952-2014_English with my colleagues?Answer: Yes. The purchased PDF of JJG 952-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 952-2014?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 952-2014 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|