JJG 749-2007: Verification Regulation of Verification Instrument for Electrocardiograph and Electroencephalograph
Status: Valid

JJG 749: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 749-2007English519 Add to Cart 4 days [Need to translate] Verification Regulation of Verification Instrument for Electrocardiograph and Electroencephalograph Valid JJG 749-2007
JJG 749-1997English399 Add to Cart 3 days [Need to translate] Verification Regulation of Calibration Device for Electrocaldiograph and Electroencephalograph Obsolete JJG 749-1997
JJG 749-1991EnglishRFQ ASK 3 days [Need to translate] Electrocardlograph Calibration Device Obsolete JJG 749-1991

PDF similar to JJG 749-2007


Standard similar to JJG 749-2007

JJF 1234   JJF 1396   JJG 376   JJG 954   JJG 561   JJG 957   

Basic data

Standard ID JJG 749-2007 (JJG749-2007)
Description (Translated English) Verification Regulation of Verification Instrument for Electrocardiograph and Electroencephalograph
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A56
Classification of International Standard 17.220
Word Count Estimation 20,240
Date of Issue 2007-06-14
Date of Implementation 2007-12-14
Older Standard (superseded by this standard) JJG 749-1997
Quoted Standard AQSIQ Announcement No. 95 of 2007
Regulation (derived from) AQSIQ Announcement No. 95 of 2007
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to ECG Calibrator, Calibrator EEG, heart, EEG Calibrator initial verification, testing and use of follow-up inspection.

JJG 749-2007: Verification Regulation of Verification Instrument for Electrocardiograph and Electroencephalograph


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Verification Instrument for Electrocardiograph and Electroencephalograph State verification procedures People's Republic of China Heart, EEG Calibrator Posted 2007-06-14 2007-12-14 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Heart, EEG Calibrator Verification Regulation Replacing JJG 749-1997 The test procedures by the State Administration of Quality Supervision, Inspection and Quarantine on June 14, 2007 approved, And shall go into effect December 14, 2007. Focal point. the National Radio Technical Commission metering Drafted by. Inner Mongolia Academy of Metrology Participated in the drafting unit. China Institute of Metrology Beijing Institute of Measurement Science This procedure commissioned the National Radio Technical Commission responsible for the interpretation of measurement The main drafters of this procedure. Ning Quan (Inner Mongolia Academy of Metrology) Lv Jinhua (Inner Mongolia Academy of Metrology) Adi almost (Inner Mongolia Academy of Metrology) Drafters participate. He Zhao (China Institute of Metrology) Chu Xiaoping (Beijing Institute of Metrology)

table of Contents

1 Scope (1) 2. Referenced Documents (1) 3 Overview (1) 4 metering performance requirements (1) 4.1 Calibrator Universal metering performance requirements (1) 4.2 ECG and heart Calibrator, Calibrator EEG additional metering performance requirements (1) 4.3 EEG and heart Calibrator, Calibrator EEG additional metering performance requirements (2) 5 General Requirements (2) 6 Control of measuring instruments (2) 6.1 Verification condition (2) 6.2 Verification Project (3) 6.3 Verification Methods (3) 6.4 Verification Results Processing (8) 6.5 test cycle (8) Original record format in Appendix A (9) Appendix B test certificate page format (13) Heart, EEG Calibrator verification procedures

1 Scope

The order applies to ECG Calibrator, Calibrator EEG machine and the heart, EEG Calibrator first seizure Given the subsequent verification and test use.

2 Citations

JJF1059-1999 "Evaluation and Expression of Uncertainty in Measurement" JJG 543-1996 (eqvOIMLR90, R89) "Heart, EEG" When using this procedure, note the use of the above citations of current valid version.

3 Overview

Calibrator ECG, EEG and heart Calibrator, Calibrator EEG (without the need to distinguish between three test When the instrument's personality, hereafter referred to as "Calibrator") is used for ECG, EEG machine to implement the technical indicators Verification of special equipment. According Calibrator dedicated master generates test signals principle can be divided into two types. Feng standard digital signal generated by the analog type Calibrator for verification by the use of a variety of standard signal. digital type Peak can be input to the analog-digital control consistent. Fengfeng standard analog signal by the analog circuit to generate Calibrator for test use, a variety of standard signal. Analog Consistency is adjusted by the value of the hardware implementation.

4 metering performance requirements

Calibrator 4.1 General metrological requirements Calibrator applies to ECG, EEG and heart Calibrator, Calibrator EEG. 4.1.1 Square Wave 4.1.1.1 amplitude. within 0.1mV ~ 5V range, the maximum permissible error of ± 1%. 4.1.1.2 cycle. in 0.01s ~ 10s range, the maximum permissible error of ± 1%. 4.1.2 sine wave 4.1.2.1 Frequency. 0.1Hz ~ 200Hz within the range of the maximum permissible error of ± 1%. 4.1.2.2 amplitude (peak to peak). in 0.1Hz ~ 200Hz, within 0.1mV ~ 5V range, the maximum permissible error ± 1%. 4.1.2.3 sine wave distortion. < 5%. 4.1.3 Polarization Voltage. 300mV and -300mV, the maximum permissible error of ± 5%. 4.2 ECG and heart Calibrator, Calibrator EEG additional measurement of performance requirements 4.2.1 Input impedance characterization with a serial impedance. 620 (1 ± 5%) kΩ resistor and 4.7 (1 ± 10%) nF capacitor in parallel. 4.2.2 Analog skin electrode impedance. 51 (1 ± 5%) kΩ resistor and 47 (1 ± 10%) nF capacitor in parallel.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 749-2007_English be delivered?

Answer: Upon your order, we will start to translate JJG 749-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 749-2007_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 749-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 749-2007?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 749-2007 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.