HOME   Cart(2)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

JJG 691-2014 English PDF

US$629.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 691-2014: Verification Regulation of Multi-Rate Electricity Meters for Measuring Alternating-current Electrical Energy
Status: Valid

JJG 691: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 691-2014English629 Add to Cart 5 days [Need to translate] Verification Regulation of Multi-Rate Electricity Meters for Measuring Alternating-current Electrical Energy Valid JJG 691-2014
JJG 691-1990English319 Add to Cart 3 days [Need to translate] Verification Regulation of Multilate Alternating-Current Watt-hour Meters Obsolete JJG 691-1990

PDF similar to JJG 691-2014


Standard similar to JJG 691-2014

JJF 1234   JJG 376   JJF 1107   JJG 892   JJG 963   JJG 843   

Basic data

Standard ID JJG 691-2014 (JJG691-2014)
Description (Translated English) Verification Regulation of Multi-Rate Electricity Meters for Measuring Alternating-current Electrical Energy
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A55
Classification of International Standard 17.220
Word Count Estimation 27,243
Date of Issue 6/15/2014
Date of Implementation 12/15/2014
Older Standard (superseded by this standard) JJG 691-1990
Quoted Standard JJG 307-2006; JJG 596-2012; JJG 597-2005; GB/T 17215.352-2009
Regulation (derived from) The State Administration of Quality Supervision, Inspection and Quarantine Notice No. 64 of 2014
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to the reference frequency of 50 Hz or 60 Hz AC power meter multi-rate (referred to as the multi-rate table) initial verification and subsequent verification. This standard is applicable to a digital display of the time switch and do

JJG 691-2014: Verification Regulation of Multi-Rate Electricity Meters for Measuring Alternating-current Electrical Energy


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Multi-Rate Electricity Meters for Measuring Alternating-current Electrical Energy State verification procedures People's Republic of China AC multi-rate meter Issued on. 2014-06-15 2014-12-15 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Multi-rate AC electrical energy meter testing procedures Replacing JJG 691-1990 Focal point. the National Technical Committee on Electromagnetic measurement Main drafting unit. Henan Institute of Metrology Henan XJ Instrument Co., Ltd. Participated in the drafting. Luohe City of Quality and Technical Supervision and Testing Center The measurement procedure commissioned the National Technical Committee is responsible for interpreting electromagnetic The main drafters of this procedure. Liu Pei (Henan Institute of Metrology) ROCKETS (Henan Institute of Metrology) Mayong Wu (Henan XJ Instrument Co., Ltd.) Drafters participate. Wang Zhongrui (Henan Institute of Metrology) Peak (Luohe City of Quality and Technical Supervision and Testing Center)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2. References (1) 3 Overview (1) 4 metering performance requirements (1) 4.1 basic error (1) 4.2 creep (2) 4.3 Start (2) Constant of 4.4 (2) 4.5 output (2) 4.6 Display (2) 4.7 day clock timing error (2) 4.8 clock indication error (2) 4.9 Indication Error of power (2) 5 General technical requirements (3) Flag 5.1 (3) 5.2 AC voltage test (3) 6 Control of measuring instruments (3) 6.1 initial verification, subsequent verification (3) 6.2 test conditions (3) 6.3 Verification Project (5) 6.4 Verification Methods (5) Processing 6.5 Verification Results (7) 6.6 test cycle (7) Appendix A multi-rate AC electrical energy meter calibration reference the original record format (8) Appendix B test certificates/test results in the notice page format (p. 2) (14) C calibration certificate/test results test results page notice Shape appendix (3) (15) Energy Test Method for Error Appendix D test with electronic counters and electronic multi-rate table (21)

Introduction

This procedure based on JJF1002-2010 "national verification procedures write rules" establishment. This procedure reference GB/T 15284-2002 "tariff applications special requirements", GB/T 17215.211- 2006 "AC measuring equipment General requirements, tests and test conditions Part 11. Measuring Device", GB/T 17215.421-2008 "exchange fee measure control and load control - Part 21. Particular requirements for time switches Seeking "and JJF1245.6-2010" installed energy meter type evaluation outlining the special requirements meter functional class " And other standards for JJG 691-1990 "mind sharing degree (multi-rate) meter test procedures" have been revised. Compared with JJG 691-1990, in addition to editorial changes, the main changes in the technical part as follows. --- Procedure name from the original "time record of (multi-rate) meter" to "multi-rate watt-hour meter exchange"; --- Changes in the scope of this procedure is only applicable to a digital display time of the switch, and battery (Or capacitance) do work backup power tariff applications; --- For electronic multi-rate watt-hour meter and electrical multi-rate energy meter metering performance requirements are proposed; --- Revised test method for measuring daily timing error; --- Increasing the clock indication error test; --- Increasing the initial verification tests for Error indication of energy. The previous versions of this Recommendation published as follows. JJG 691-1990 "mind sharing degree (multi-rate) meter test procedures" Multi-rate AC electrical energy meter testing procedures

1 Scope

The order applies to the reference frequency of 50Hz or 60Hz AC power meter multi-rate (referred to as the multi-rate table) Initial verification and subsequent verification. The order applies to a digital display time of the switch, the power supply and do backup battery (or capacitor) Multi-rate tables. For multifunction meter with a time-measurement, the same verification procedure of the project implementation. This procedure does not apply to the field of multi-rate table test. 2. References This procedure refers to the following documents. JJG 307-2006 electromechanical AC power meter JJG 596-2012 electronic AC power meter JJG 597-2005 AC power meter testing equipment GB/T 17215.352-2009 AC measuring equipment - Specific requirements - Part 52. Symbols For dated references, only the dated edition applies to this procedure; undated reference documents Member, the latest edition (including any amendments) applies to this procedure.

3 Overview

Multi-rate tables, also known as time-measurement meter or multi-rate meter, which is provided with a plurality of counters, each counter and in Predetermined period of time corresponding to different rates of Implementation of work. Multi-rate tables mainly by energy measurement unit, clocked Unit, counters and other components. Counters may be an electromechanical device or a reservoir and a display by the group It can be stored into the electronic device and display information. A single electronic display, a plurality of electronic reservoir for use To form a plurality of electronic counters and. According to the principle of energy measurement unit, multi-rate table can be divided into electronic multi-rate tables and electromechanical multi-rate tables. Energy measurement unit electronic multi-rate table is constituted by a solid-state electronic components; electromechanical energy measurement single multi-rate table Yuan is the induction system measuring mechanism.

4 metering performance requirements

4.1 basic error Electronic multi-rate meter shall comply JJG 596-2012 4 metering performance requirements; Electromechanical Multi-rate tables should comply JJG 307-2006 3 metering performance requirements.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 691-2014_English be delivered?

Answer: Upon your order, we will start to translate JJG 691-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 691-2014_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 691-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 691-2014?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 691-2014 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.