HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (13 Apr 2025)

JJG 42-2023 English PDF (JJG 42-2011: Older version)

Search result: JJG 42-2023 (JJG 42-2011 Older version)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 42-2023English1059 Add to Cart 7 days [Need to translate] Working Glass Hydrometers Valid JJG 42-2023
JJG 42-2011English1519 Add to Cart 6 days [Need to translate] Verification Regulation of Working Glass Hydrometers Obsolete JJG 42-2011
JJG 42-2001EnglishRFQ ASK 6 days [Need to translate] Verification Regulation of Working Glass Hydrometers Obsolete JJG 42-2001
JJG 42-1987EnglishRFQ ASK 3 days [Need to translate] Verification Regulation of Working Glass Hydrometers Obsolete JJG 42-1987


BASIC DATA
Standard ID JJG 42-2023 (JJG42-2023)
Description (Translated English) Working Glass Hydrometers
Sector / Industry Metrology & Measurement Industry Standard
Word Count Estimation 48,477
Date of Issue 2023-03-15
Date of Implementation 2023-09-15


JJG 42-2023 National Metrology Verification Regulations of the People's Republic of China JJG 42-2023 working glass float Released on 2023-03-15 2023-09-15 Implementation Released by the State Administration for Market Regulation Verification rules for working glass buoyancy gauge Replace JJG 42-2011 Responsible unit: National Quality and Density Measurement Technical Committee Main drafting unit: China Institute of Metrology Shanxi Institute of Metrology Participating in the drafting unit: Yunnan Institute of Metrology and Testing Technology Guangdong Institute of Metrology Metrology and Verification Center of North China Company of China Aviation Fuel Co:, Ltd: Yuyao Instrument No:2 Factory Co:, Ltd: This regulation entrusts the National Quality and Density Measurement Technical Committee to be responsible for interpretation The main drafters of this regulation: Shi Wencai (National Institute of Metrology) Gao Ping (Shanxi Institute of Metrology) Participating drafters: Zhang Jingyue (National Institute of Metrology) Yang Lixian (Yunnan Institute of Metrology and Testing Technology) Shen Youdi (Guangdong Institute of Metrology) Rong Youzhan (North China Company Metrology and Verification Center of China Aviation Fuel Co:, Ltd:) Ding Zhuyi (Yuyao Second Instrument Factory Co:, Ltd:) Table of contents Introduction (Ⅲ) 1 range(1) 2 References(1) 3 Terms and units of measurement(1) 3:1 Terminology(1) 3:2 Units of measurement(1) 4 Overview(1) 5 Metrological performance requirements (2) 6 General technical requirements (2) 6:1 Appearance(2) 6:2 Standard temperature(3) 7 Measuring Instrument Control(3) 7:1 Test conditions (3) 7:2 Verification items and verification methods (7) 7:3 Test result processing (11) 7:4 Verification cycle (11) Appendix A (0~40)℃ pure water density table (excluding air) (12) Appendix B Alcohol Solution Volume Fraction q and Density ρ Conversion Table at 20°C (14) Appendix C Conversion table of sugar solution mass fraction p and density ρ at 20°C (15) Appendix D Conversion Table of Milk Degree m° and Density ρ20 at 20°C (16) Appendix E Conversion Table of Soil Degree s° and Density ρ20 at 20°C (17) Appendix F Conversion Table of Baume Degree Bh and Density ρ20 at 20°C (18) Appendix G Capillary Constant α of Liquids Denser Than Water (19) Appendix H Surface Tension of Liquids Denser Than Water γ (21) Appendix J Capillary Constant α of Liquids Denser Than Water (23) Appendix K Surface Tension of Liquids Denser Than Water γ (26) Appendix L Potassium Iodide, Mercury Iodide Aqueous Capillary Constant α and Surface Tension γ (29) Appendix M Sugar solution capillary constant α (30) Appendix N Surface Tension of Sugar Solutions γ (31) Appendix P Air Density Calculation Formula (32) Appendix Q Humid Air Density Table (34) APPENDIX R CONVERSION RELATIONSHIP BETWEEN THE ASSUMPTED SCALE AND DENSITY OF SEVERAL WORKING GLASS FLOAT GAUGES (36) Appendix S Verification Record Format of Working Glass Buoyometer Stem Diameter (37) Appendix T Original Record Format of Density Verification by Static Weighing Method (38) Appendix U Original Record Format of Density Verification by Direct Comparison Method (39) Appendix V Format of the inner page of the verification certificate (40) Appendix W Format of the inner page of the test result notification (41) introduction JJF1002-2010 "Rules for Compilation of National Metrology Verification Regulations", JJF1229-2009 "Mass Density Measurement Name" Terms and Definitions", ISO 649-2:1981 "General Density Meter for Laboratory Glassware - Part 2: Tests "Methods and Use" together constitute the basic series of specifications supporting the formulation of this verification regulation: This regulation combines the industry status and actual needs of my country's standard glass measuring instrument measurement, to JJG 42-2011 "Industrial As Glass Buoymeter" has been revised: Compared with JJG 42-2011, except for editorial modifications, the main technical The changes are as follows: --- Increase the solid density standard as a measurement standard; --- In the main supporting equipment and instruments section, the components used in the direct comparison method and hydrostatic weighing method are listed in detail measuring instrument; --- The verification method and data processing section increased the operation steps and calculation formula of the hydrostatic weighing method; ---Added Appendix H "Surface Tension γ of Liquids with Density Less Than Water"; --- Added Appendix K "Surface Tension γ of Liquids Denser Than Water"; --- Modified Appendix L, adding potassium iodide and mercury iodide aqueous solution surface tension; --- Added Appendix N "Surface Tension of Sugar Solution γ"; --- Added Appendix S "Glass Buoyometer Stem Diameter Record Format"; ---Modified Appendix T "Original Record Format of Density Verification by Static Weighing Method"; --- Added Appendix U "Direct Comparison Method Density Verification Original Record Format": The previous releases of this regulation are as follows: ---JJG 42-2011; ---JJG 42-2001: Verification rules for working glass buoyancy gauge 1 Scope This regulation is applicable to quality fixation of density meters, oil density meters, alcohol meters, sugar meters, milk meters, soil meters, etc: The initial verification, follow-up verification and in-use inspection of the type working glass float meter: 2 References This procedure references the following documents: JJG 2094 Density Measuring Instrument Verification System Table JJF1229 Terms and Definitions of Mass Density Measurement GB/T 17764 Structure and Calibration Principles of Density Meter ISO 649-2 Density meter for general purpose laboratory glassware - Part 2: Test method and use (Labo- use) For dated references, only the dated version applies to this specification; for undated references document, its latest version (including all amendments) applies to this specification: 3 Terminology and units of measurement 3:1 Terminology 3:1:1 Hydrostatic weighing method hydrostaticweighing Based on Archimedes' law, by weighing the buoyancy of the glass buoy meter immersed in the liquid in a steady state To determine the volume of its submerged part, and calculate the density value of the point of the glass float meter: 3:2 Units of measurement The unit of density is kg/m3 or g/cm3: The unit of the volume fraction of the alcohol solution is % (at 20°C, see the conversion table of the volume fraction q of the alcohol solution and the density ρ Appendix B): The unit of sugar solution mass fraction is % (see Appendix C for conversion table of sugar solution mass fraction p and density ρ at 20°C): The unit of milk degree is m° (for the conversion table of milk degree and ρ20, see Appendix D, and for the conversion formula, see Appendix R): The unit of soil degree is s° (see Appendix E for the conversion table of soil degree and ρ20, and Appendix R for the conversion formula): The unit of Baume degree is Bh (for the conversion table of Baume degree and ρ20, please refer to Appendix F, and for the conversion formula, please refer to Appendix R): 4 Overview The glass float gauge is a kind of glass that can float vertically and freely in the liquid, and can directly measure the liquid by its submerged depth in the liquid: An instrument for bulk density, relative density or solution concentration, the structure of which is shown in Figure 1: ......


JJG 42-2011 Verification Regulation of Working Glass Hydrometers State verification procedures People's Republic of China Working glass hydrometers Issued on. 2011-09-20 2012-03-20 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Working glass hydrometers test procedures WorkingGlassHy drometers Replacing JJG 42-2001 The regulations by the State Administration of Quality Supervision, Inspection and Quarantine approved on September 20, 2011, and from From March 20, 2012 into effect. Focal point. the quality and density measurement technology committee The main drafting units. China Institute of Metrology Participated in the drafting unit. Liaoning Provincial Institute of Metrology Jizhou City Yaohua instrument Factory This procedure commissioned by the quality and density measurement technology committee responsible for the interpretation The main drafters of this procedure. Xu Chang Hong (China Institute of Metrology) Chen Zhaohui (China Institute of Metrology) Gu Yingzi (China Institute of Metrology) Drafters participate. Mengshu Yan (Liaoning Provincial Institute of Metrology) Xu Yan hair (Jizhou Yaohua instrument Factory) table of Contents 1 Scope (1) 2. References (1) 3 terminology and units of measurement (1) 4 Overview (1) 4.1 Several common hydrometers assumed conversion between the scale and density (2) 5 metering performance requirements (3) 6 General Requirements (3) 6.1 Appearance (3) 6.2 standard temperature (3) Labeled 6.3 (3) 7 control of measuring instruments (4) 7.1 test conditions (4) 7.2 test items and test methods (7) 7.3 test results processing (11) 7.4 test cycle (11) Appendix A 0 ℃ ~ 40 ℃ water density meter (excluding air) (12) Appendix B 20 ℃ when aqueous ethanol volume fraction and density ρ q conversion table (14) Appendix C 20 ℃ when the mass fraction of the sugar solution and the density ρ p conversion table (15) Appendix D 20 ℃ when the degree of milk (m °) and the density ρ20 conversion table (16) Appendix E 20 ℃ when soil degree (s °) and the density ρ20 conversion table (17) Appendix F 20 ℃ when Baume (Bh) and the density ρ20 conversion table (18) Appendix G less dense than liquid water capillary constant α (19) Appendix H is greater than the density of liquid water capillary constant α (21) Appendix J potassium iodide aqueous mercury capillary constant α (24) Appendix K sugar solution capillary constant α (25) Appendix L air density calculating equation (26) Appendix M wet air density meter (27) Appendix N hydrostatic weighing method original recording density test 1 (29) Appendix P hydrostatic weighing method original recording density test 2 (30) Appendix Q test certificate-page format (31) Appendix R test results in the notice page format (32) Working glass hydrometers test procedures 1 Scope The order applies to density meter, a fixed quality hydrometer, alcohol meter, glucose meter, milk meter, meter soil, etc. Type working glass hydrometers (hereinafter referred to as hydrometers) initial verification, use and subsequent verification check. This procedure does not apply less than 650kg/m3 density range of petroleum hydrometer test. 2. References JJF1229-2009 mass density measurement terminology and definitions JJG 2094-2010 density measuring instruments Verification System GB/T 17764-2008 densitometer calibration structure and principles For dated references, only the dated edition applies to this procedure; undated reference documents Member, the latest edition (including any amendments) applies to this procedure. 3 terminology and units of measurement The relative density of 3.1 relativedensity Under specified conditions, than the material density ρ1 and ρ2 of reference material density, represented by d. See equation (1). d = ρ1/ρ2 (1) Note. d-free units that dimensionless quantity. In the field of density measurement, reference materials commonly used for liquid and solid water, usually with respect to gas Its gas pressure and dry air at the same temperature. For example, the statutes of seawater density meter scale relative density single Bit, meaning the ratio of the density of seawater at 17.5 ℃ when the density of pure water at 17.5 ℃, the symbol d17.517.5 to represent. 3.2 hydrostatic weighing method hydrostaticweighing Based on Archimedes' principle, by weighing immersed in the liquid glass hydrometers suffered in the steady state the size of buoyancy To determine the volume of immersed portion of the meter and calculate floating point density value method. 4 Overview Float glass is a meter in the liquid free-floating vertically, by its immersion depth in the liquid to directly measure the fluid Density, relative density or concentration of the instrument, the structure shown in Fig. Figure 1, the upper part of the glass hydrometers dry tube top seal, uniform diameter elongated tube, close the tube has a press density, The relative density or concentration of marker ruler. Body is conical or hemispherical bottom (to avoid air bubbles attached) hollow Cylinder, the lower part is made of glass partitions or other structures made of ballast compartment, interior filled with small lead pellets or other suitable Filler for ballast. ......

Similar standards: JJG 134   JJG 86   JJF 042