US$699.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 338-2013: Verification Regulation of Charge Amplifiers Status: Valid JJG 338: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 338-2013 | English | 699 |
Add to Cart
|
5 days [Need to translate]
|
Verification Regulation of Charge Amplifiers
| Valid |
JJG 338-2013
|
JJG 338-1997 | English | 639 |
Add to Cart
|
5 days [Need to translate]
|
Verification Regulation of Charge Amplifier
| Obsolete |
JJG 338-1997
|
JJG 338-1983 | English | RFQ |
ASK
|
3 days [Need to translate]
|
(Chinese Industry Standard)
| Obsolete |
JJG 338-1983
|
PDF similar to JJG 338-2013
Basic data Standard ID | JJG 338-2013 (JJG338-2013) | Description (Translated English) | Verification Regulation of Charge Amplifiers | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A56 | Classification of International Standard | 17.160 | Word Count Estimation | 30,311 | Older Standard (superseded by this standard) | JJG 338-1997 | Quoted Standard | JJG 233-2008; JJG 449-2001; JJG 834-2006; JJF 1156-2006; JJF 1269-2010; GB/T 20485.1-2008 | Regulation (derived from) | AQSIQ Notice No. 154 of 2013 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to: Charge Amplifier initial verification, testing and use of the follow-up examination. |
JJG 338-2013: Verification Regulation of Charge Amplifiers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Charge Amplifiers
State verification procedures People's Republic of China
Charge amplifier
Issued on. 2013-10-25
2014-04-25 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Charge amplifier test procedures
Replacing JJG 338-1997
Focal point. the National Technical Committee of shock and vibration measurement speed
The main drafting units. China Aviation Industry Corporation Beijing Great Wall Measurement and Testing Technology
graduate School
Participated in the drafting unit. Beijing Institute of Metrology detection
Yangzhou English Mike Control Technology Co.,
This procedure entrust national shock and vibration speed measurement technology committee responsible for the interpretation
The main drafters of this procedure.
Shao Xinhui (China Aviation Industry Corporation Beijing Great Wall Measurement and Testing Technology Institute
The study)
I had (China Aviation Industry Corporation Beijing Great Wall Measurement and Testing Technology Institute
The study)
Drafters participate.
Zhang Ningning (China Aviation Industry Corporation Beijing Great Wall Measurement and Testing Technology Institute
The study)
Lixue Rui (Beijing Institute of Metrology detection)
CHEN Qi-Shan (Yangzhou English Mike Control Technology Co.)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 terminology and units of measurement (1)
3.1 Gain block (1)
3.2 normalized block (1)
3.3 Transfer Coefficient (1)
4 Overview (1)
5 metering performance requirements (2)
5.1 Classification charge amplifier (2)
5.2 Input equivalent noise charge (3)
5.3 normalized error (3)
5.4 Gain block error (3)
5.5 linearity error (3)
5.6 Distortion (3)
5.7 low-pass filter cut-off frequency (upper limit frequency) (3)
5.8 high-pass filter cut-off frequency (lower limit frequency) (3)
5.9 Frequency characteristic (4)
5.10 phase-frequency characteristic (4)
5.11 error integrator (4)
6 General Requirements (4)
6.1 appearance requirements (4)
6.2 Other technical requirements (4)
7 control of measuring instruments (4)
7.1 test conditions (4)
7.2 Verification Project (5)
7.3 Verification Methods (5)
7.4 test results processing (15)
7.5 test cycle (15)
Appendix A is equivalent to the lower limit frequency derivation (16)
Appendix B assay format recommended by the original record (17)
Appendix C calibration certificate/test results in the notice page and format (21)
Introduction
This procedure based on JJF1002-2010 "national verification procedures to write rules" for JJG 338-1997 "electricity
Charge Amplifier "revision, compared with JJG 338-1997, in addition to editorial changes, the major technical changes are as follows.
--- The "attenuation block" changed to "gain block";
--- Abolition of the "accuracy of synthesis" is defined;
--- Modify the charge amplifier INES, increased levels of "a", the abolition of the "accuracy"
"0.5dB maximum frequency" and "distortion" level determination conditions, to increase the "gain block error" level determination
condition;
--- Improve the technical requirements normalized error, linearity error, and distortion;
--- The "limit frequency" instead of looking for "high-pass filter cutoff frequency attenuation limit amount" of judgment;
--- The "low-pass filter cut-off frequency error" on the decision to "low-pass filter cutoff frequency attenuation limit
Determined quantity ";
--- Canceled "0.5dB maximum frequency" test project;
--- Added "digital normalized block" and "verification method normalized error";
--- Increasing the amplitude-frequency characteristics and phase-frequency characteristics of the measurement performance requirements;
--- Refine the measurement of performance requirements integrator errors.
The previous versions of the release JJG 338-1997 case.
--- JJG 338-1983.
Charge amplifier test procedures
1 Scope
The order applies to the charge amplifier initial verification, subsequent verification and the use of checks.
2. References
This procedure references the following documents.
JJG 233-2008 piezoelectric accelerometer test procedures
JJG 449-2001 octave and 1/3 octave filter test procedures
JJG 834-2006 Dynamic Signal Analyzer
JJF1156-2006 vibration, shock, speed measurement terms and definitions
JJF1269-2010 integrated circuit piezoelectric sensors (IEPE) amplifier calibration specification
GB/T 20485.1-2008 vibration and shock sensor calibration methods - Part 1. Basic Concepts
For dated references, only the dated edition applies to this procedure; undated reference documents
Member, the latest edition (including any amendments) applies to this procedure.
3 terminology and units of measurement
The following terms and definitions apply to this procedure.
3.1 Gain block gainswitch
Charge amplifier "output amplifier" function module selector switch or button, which variables G, the unit
It is V/Unit.
3.2 normalized block unityswitch
Selector switch or button charge amplifier "normalization amplifier" function module, also called "sensor sensitivity
Block "the variables are represented by S units of pC/Unit.
3.3 transmission coefficient transmissioncoefficient
Charge amplifier input and output voltage ratio of the amount of charge, with the T, in units of pC/V.
4 Overview
The charge amplifier is a preamplifier piezoelectric transducer, whose output voltage is proportional to the input charge. Electric charge
Amplifiers are widely used in vibration, shock, force, pressure, sound intensity and other non-power electrical measurement in.
--- Core charge conversion level of the charge amplifier is a specific form of an operational amplifier, shown in Figure 1. Wherein Ci
Sensor and wire equivalent capacitance, Cf is the feedback capacitor charge conversion stage.
According to the theory of the op amp open-loop gain and high input impedance of the charge amplifier and the output voltage eo
The relationship between the input electromotive force ei see equation (1).
Potentials UΣ point 1 is almost zero, so-called virtual place, so the capacitor plates charge Ci Qi
The relationship between the electromotive force ei can be expressed as a formula (2).
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 338-2013_English be delivered?Answer: Upon your order, we will start to translate JJG 338-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 338-2013_English with my colleagues?Answer: Yes. The purchased PDF of JJG 338-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 338-2013?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 338-2013 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|