JJG 308-2013: Verification regulation of RF Votlmeters
Status: Valid

JJG 308: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 308-2013English279 Add to Cart 3 days [Need to translate] Verification regulation of RF Votlmeters Valid JJG 308-2013
JJG 308-1983English319 Add to Cart 3 days [Need to translate] Verification Regulation of SHF Electronic Millivoltmeter Obsolete JJG 308-1983

PDF similar to JJG 308-2013


Standard similar to JJG 308-2013

JJF 1234   JJF 1396   JJG 376   JJG 954   JJG 561   JJG 957   

Basic data

Standard ID JJG 308-2013 (JJG308-2013)
Description (Translated English) Verification regulation of RF Votlmeters
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A56
Classification of International Standard 17.220
Word Count Estimation 12,158
Older Standard (superseded by this standard) JJG 279-1981; JJG 308-1983; JJG 319-1983
Regulation (derived from) ?State AQSIQ Announcement 2013 No. 28
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to frequencies within the range of 2 GHz, voltage measurement range of 300 ��V ~ 100 V RF voltage meter (hereinafter referred to as the voltmeter) initial verification, follow-up test and use checks.

JJG 308-2013: Verification regulation of RF Votlmeters

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification regulation of RF Votlmeters State verification procedures People's Republic of China RF voltmeter RFVoltmeters Issued on. 2013-02-16 2013-08-16 implementation The State Administration of Quality Supervision, Inspection and Quarantine released RF voltage meter testing procedures Replacing JJG 279-1981 JJG 308-1983 JJG 319-1983 Focal point. the National Radio Technical Commission metering Drafting units. China Institute of Metrology Guangdong Provincial Institute of Metrology This procedure commissioned the National Radio Technical Commission responsible for the interpretation of measurement The main drafters of this procedure. Huang Jian-ming (China Institute of Metrology) Zhu Sijie (Guangdong Institute of Metrology) Tao Yi (China Institute of Metrology) This procedure drafters participate. Zhang Nan (Guangdong Institute of Metrology) Tian Wei (China Institute of Metrology)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2 Overview (1) 3 metering performance requirements (1) 3.1 basic error voltage (1) 3.2 Additional frequency error (1) 4 General Requirements (1) 4.1 Visual inspection (1) 4.2 function tests (1) 4.3 energizing check (1) 5 control of measuring instruments (2) 5.1 verification Conditions (2) 5.1.1 Environmental conditions (2) 5.1.2 The test equipment (2) 5.2 test items and test methods (2) 5.3 test results processing (4) 5.4 test cycle (4) Appendix A test record form (5) B test certificates/test results in the notice page format Shape appendix (6)

Introduction

The rules of order within the frequency range of 2GHz RF voltmeter test method is JJG 279-1981 "WFG-1B high-frequency micro-volt meter", JJG 308-1983 "UHF millivoltmeter" and JJG 319-1983 "UHF Microvolt table "revision. These three test procedures have been implemented for 20 years. With the radio measurement technology continues Development, radio voltage measurement mode has also been greatly improved and changed. In particular digital voltmeter has gradually Replace the low-frequency electronic voltmeter measuring, electronic voltmeter low frequency range has also been extended to the ultra-high frequency band. Thus, the old regulations on certain technical requirements for the practical requirements of today has been incompatible. Prepared on the basis of this Regulation JJF1002-2010 "national verification procedures writing rules" and JJF1059 "Evaluation and Expression of Uncertainty in Measurement" carry out. In the revision, extension of the original protocol of the frequency range and voltage range, has been adapted to the current actual RF voltmeter Verification requirements. RF voltage meter testing procedures

1 Scope

The order applies to frequencies within the range of 2GHz, the voltage measurement range of RF power 300μV ~ 100V Pressure gauge (hereinafter referred to as voltmeter) initial verification, use and subsequent verification check.

2 Overview

RF voltmeter is an important measurement of radio instruments. Usually by the detector, dividers, amplifiers and indicators constitute. After the detector RF signal detector, DC amplifier for DC signal detection after amplification, and then by the finger Indicator indicating voltage values measured. Widely used in measuring radio and working conditions of electronic circuits or components. Xu Multi-parameter measuring instrument basis.

3 metering performance requirements

3.1 voltage basic error Voltage basic error. ± 3% (100kHz). 3.2 Additional frequency error Additional frequency error. ± 3% (100kHz ~ 50MHz, ≥10mV); ± 5% (20kHz ~ 200MHz, ≥3mV); ± 15% (20kHz ~ 1GHz, ≥3mV); ± 20% (10kHz ~ 2GHz, ≥1mV). When the test subject to be seized equipment technical indicators.

4 General technical requirements

4.1 Visual inspection Voltmeter should have a factory, instrument name, instrument model, serial number and power requirements. Control voltmeter Knob, key switch, input and output ports should be clearly marked. 4.2 Functional Check Before being energized there should be no prejudice to the subject voltmeter readings and affect the normal mechanical damage, control knobs and buttons should To work properly, the display to show, all kinds of signs should be clear and complete; pointer instrument gauge needles should bend, Header mechanical zero can be adjusted freely and so on. 4.3 energizing check After being seized voltmeter energized preheated pointer instrument should be able to adjust the electrical zero and from school. Added signal table Head should be indicative and not jammed and jumping phenomenon.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 308-2013_English be delivered?

Answer: Upon your order, we will start to translate JJG 308-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 308-2013_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 308-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 308-2013?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 308-2013 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.