US$879.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 160-2007: Verification Regulation of Standard Platinum Resistance Thermometer Status: Valid JJG 160: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 160-2007 | English | 879 |
Add to Cart
|
6 days [Need to translate]
|
Verification Regulation of Standard Platinum Resistance Thermometer
| Valid |
JJG 160-2007
|
JJG 160-1992 | English | 599 |
Add to Cart
|
4 days [Need to translate]
|
Verification Regulation of Standard Platinum Resistance Thermometer
| Obsolete |
JJG 160-1992
|
JJG 160-1982 | English | RFQ |
ASK
|
3 days [Need to translate]
|
(Chinese Industry Standard)
| Obsolete |
JJG 160-1982
|
PDF similar to JJG 160-2007
Basic data Standard ID | JJG 160-2007 (JJG160-2007) | Description (Translated English) | Verification Regulation of Standard Platinum Resistance Thermometer | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A54 | Classification of International Standard | 17.200.10 | Word Count Estimation | 35,332 | Date of Issue | 2007-06-14 | Date of Implementation | 2007-12-14 | Older Standard (superseded by this standard) | JJG 160-1992; JJG 716-1991; JJG 859-1994 | Quoted Standard | AQSIQ Announcement No. 95 of 2007 | Regulation (derived from) | AQSIQ Announcement No. 95 of 2007 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to -189. 344��C ~ 660. 323��C operating reference, first-class and second-class standard platinum resistance thermometer initial verification and follow-up examination. |
JJG 160-2007: Verification Regulation of Standard Platinum Resistance Thermometer---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Standard Platinum Resistance Thermometer
State verification procedures People's Republic of China
Standard platinum resistance thermometer
Posted 2007-06-14
2007-12-14 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Standard platinum resistance thermometer
Verification Regulation
StandardPlatinum ResistanceThermometer
Replacing JJG 160-1992
JJG 716-1991
JJG 859-1994
The regulations by the State Administration of Quality Supervision, Inspection and Quarantine, 2007 June 14 ratification and
From December 14, 2007 implementation.
Focal point. the National Technical Committee of temperature measurement
Drafting units. China Institute of Metrology
Fluke Companies
Const Beijing Science and Technology Development Co., Ltd.
Kunming generous Automatic Control Technology Co., Ltd.
Beijing Guodian Di Yang Electrical Equipment Co.,
The regulations of the National Commission explained temperature measurement technology
The drafters of the regulations.
Wang Yulan (China Institute of Metrology)
Wu lian (China Institute of Metrology)
Qiu Ping (China Institute of Metrology)
Chang (China Institute of Metrology)
Feng Yuling (China Institute of Metrology)
This specification drafters participate.
Li Dazhong (Fluke company)
Jiang Weili (Const Beijing Science and Technology Development Co., Ltd.)
Lifu Hong (Kunming generous automatic control technology limited liability company)
Xiaoyong Jun (Beijing Guodian DeYoung Electrical Equipment Co., Ltd.)
table of Contents
1 Scope (1)
2 Overview (1)
2.1 Definition of the interpolation method temperature value (1)
2.2 Description of Symbols (2)
3 metering performance requirements (2)
3.1 Resistance Characteristics (2)
3.2 Technical conditions (2)
4 General technical requirements (4)
4.1 Dimensions (4)
4.2 Structure (4)
5 control of measuring instruments (4)
5.1 test conditions (4)
5.2 Verification Project (5)
5.3 Verification Methods (5)
5.4 formula (11)
5.5 test results processing (13)
5.6 test cycle (13)
Appendix A calibration certificate (back) format (14)
Appendix B test results of notice (back) format (15)
Appendix C Reference function Wr (t) of the coefficient table of values (16)
Appendix D to calculate W (100 ℃) formula coefficient K value table (17)
Appendix E (-189.3442 ~ 0.01) ℃ temperature region reference function table (19)
Appendix F (0 ~ 660.323) ℃ temperature region reference function table (22)
Standard platinum resistance thermometer test procedures
1 Scope
The order applies to -189.3442 ℃ ~ 660.323 ℃ (or sub-zone) reference work, first-class and second-class standard
Platinum resistance thermometer initial verification and subsequent verification.
2 Overview
Standard platinum resistance thermometer is a standard based on platinum wire resistance changes with temperature single-valued characteristics of temperature
instrument.
Standard platinum resistance thermometer uses for. the national reference platinum resistance thermometer to the work of reference platinum resistance thermometer test
The standard means; a reference work for the first-class standard platinum resistance thermometers standard platinum resistance thermometer detector device; and a
And other standard platinum resistance thermometer as second-class standard platinum resistance thermometer is standard verification equipment; standard platinum resistance thermometers
Used to measure directly, but also as a variety of standard compares measured.
2.1 Definition of temperature values and interpolation methods
1990 International Temperature Scale (ITS-90) at a predetermined temperature value -189.3442 ℃ ~ 660.323 ℃ temperature region by the
A set of provisions to define a fixed point indexing standard platinum resistance thermometer to determine, define a fixed point include freezing point of aluminum, zinc and condensate
Fixed-point, freezing point of tin, indium freezing point, the melting point of gallium, mercury triple point, the argon triple point and triple point of water means, and use regulations
And function within the given reference deviation function interpolation calculation defined temperature value fixed point.
Temperature value is determined by the following formula.
W (t) = R (t)/R (0.01 ℃) (1)
Where, W (t) is a standard platinum resistance thermometer electrical resistance values of the temperature t and the triple point of water temperature (0.01 ℃) of
Resistance ratio.
In reference to the function definition 0 ℃ ~ 660.323 ℃ temperature zone for
Wr (t) = C0 Σ
i = 1
Ci [(t/℃ -481)/481] i (2)
(3) for the formula (2) the inverse function, it is within the 0.13mK consistent with the formula (2).
t/℃ = D0 Σ
i = 1
Di {[Wr (t) -2.64] /1.64} i (3)
Where, t is the temperature value; Wr (t) is a reference function, at 0 ℃ ~ 660.323 ℃ temperature region reference function Wr (t)
Table of values in Appendix F; constant C0, Ci, D0, Di listed in Appendix C.
In deviation function 0 ℃ ~ 660.323 ℃ temperature zone for
ΔW (t) = W (t) -Wr (t) = a [W (t) -1] b [W (t) -1] 2 c [W (t) -1] 3 (4)
Wherein, a, b, c are coefficients, the coefficients a, b, c is a standard platinum resistance thermometer at the triple point of water, condensate tin
Fixed-point, freezing point deviation measuring zinc and aluminum freezing point temperature determined W value and the corresponding reference function is obtained.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 160-2007_English be delivered?Answer: Upon your order, we will start to translate JJG 160-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 160-2007_English with my colleagues?Answer: Yes. The purchased PDF of JJG 160-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 160-2007?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 160-2007 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|