HOME   Cart(3)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJG 1180-2021 English PDF

US$469.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 1180-2021: Power Frequency Ground Impedance Testers for Large Grounding Grid
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 1180-2021English469 Add to Cart 4 days [Need to translate] Power Frequency Ground Impedance Testers for Large Grounding Grid Valid JJG 1180-2021

PDF similar to JJG 1180-2021


Standard similar to JJG 1180-2021

JJF 1234   JJF 1187   JJG 376   JJF 2000   JJG 1177   JJG 1176   

Basic data

Standard ID JJG 1180-2021 (JJG1180-2021)
Description (Translated English) Power Frequency Ground Impedance Testers for Large Grounding Grid
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A55
Word Count Estimation 21,287
Issuing agency(ies) State Administration for Market Regulation

JJG 1180-2021: Power Frequency Ground Impedance Testers for Large Grounding Grid

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(The procedure of power frequency grounding tester for large grounding grid) People's Republic of China National Metrological Verification Regulations Large-scale grounding grid power frequency grounding impedance tester Published on 2021-10-18 2022-04-18 Implementation Released by the State Administration for Market Regulation Large-scale grounding grid power frequency grounding impedance tester Verification procedures Focal Point. National Electromagnetic Metrology Technical Committee Main drafting unit. National High Voltage Metering Station Shandong Institute of Metrology State Grid Hunan Electric Power Company Electric Power Research Institute Participating in the drafting unit. Electric Power Research Institute of Guangdong Power Grid Corporation Wuhan Kangda Electric Co., Ltd. This regulation entrusts the National Electromagnetic Metrology Technical Committee to be responsible for the interpretation The main drafters of this regulation. Wang Haiyan (National High Voltage Metering Station) Ma Xuefeng (Shandong Institute of Metrology) Qi Fei (State Grid Hunan Electric Power Company Electric Power Research Institute) Wang Siqi (National High Voltage Metering Station) Participating drafters. Li Qian (Guangdong Power Grid Corporation Electric Power Research Institute) Wang Xinyan (Shandong Institute of Metrology) Hu Xiaohui (Wuhan Kangda Electric Co., Ltd.)

content

Introduction (Ⅱ) 1 Scope(1) 2 References (1) 3 Terms and units of measurement(1) 4 Overview(1) 5 Measurement performance requirements (2) 5.1 Main measurement parameters (2) 5.2 Maximum allowable error and accuracy class(2) 5.3 Influence of auxiliary electrode grounding resistance (3) 5.4 Power frequency ground interference voltage rejection ratio (3) 6 General technical requirements (3) 6.1 Appearance(3) 6.2 Insulation resistance(4) 6.3 Dielectric strength(4) 7 Measuring Instrument Control (4) 7.1 Verification Conditions (4) 7.2 Verification items and verification methods (4) 7.3 Processing of Verification Results (7) 7.4 Verification Period(7) Appendix A Verification Original Record Format (8) Appendix B Verification Certificate/Inner Page Format of Verification Result Notification (Page 2) (11) Appendix C Verification Certificate/Verification Result Notification Verification Result Page Format (Page 3) (12) Appendix D Description, Calculation and Test Method of Engineering Ground Interference Voltage Rejection Ratio (14)

Introduction

JJF1002-2010 "Rules for the Compilation of National Metrology Verification Regulations", JJF1001 "General Metrology Terms and Definitions", JJF1059.1-2012 "Assessment and Representation of Measurement Uncertainty" together constitute the basis for supporting the preparation of this Regulation specification. This regulation is published for the first time. Large-scale grounding grid power frequency grounding impedance tester verification rules

1 Scope

This regulation is applicable to the grounding of large-scale grounding grids with a working frequency of 45Hz~55Hz and a working current of not less than 1A. The initial verification, subsequent verification and in-use inspection of an impedance tester or device (hereinafter referred to as the tester). This regulation does not apply to battery-powered, hand-cranked generators and grounding resistance meters with analog indication.

2 Reference documents

This procedure cites the following documents. GB/T 13978─2008 Digital Multimeter GB 50169─2016 Code for construction and acceptance of grounding devices for electrical installation installation engineering For dated citations, only the dated version applies to this Regulation; for undated citations The latest version (including all amendments) applies to this regulation.

3 Terminology and units of measurement

3.1 ground impedance groundimpedance The impedance between a given point and a reference point of an earthed system, installation or equipment at a given frequency. [GB 50169-2016, definition 2.0.7] 3.2 Ground resistance groundresistance The real part of the grounding impedance is the power frequency grounding resistance at power frequency. [GB 50169-2016, definition 2.0.8] Grounding devices for substations and high-voltage laboratories with voltage levels of 110kV and above, or with an installed capacity of.200MW The grounding device of the above power plant, or the grounding grid (device) with an equivalent area of more than 5000m2. 3.4 rated current ratedcurrent The current value at which the measuring device reaches its rated operating state. When measuring the ground impedance, the resistances RC and RP between the auxiliary electrode and the ground, where RC is the auxiliary current electrode and The resistance between the earth, RP is the resistance between the auxiliary voltage pole and the earth. When the test current is not applied, the power frequency voltage between the auxiliary voltage pole of the tester and the grounding device under test. A parameter that reflects the tester's ability to suppress power-frequency ground interference voltage, and its magnitude is determined by the power-frequency ground interference voltage suppression ratio KE to quantify the characterization.

4 Overview

Large-scale grounding grid power frequency grounding impedance tester (device) is widely used to measure the power frequency of large-scale grounding grid (device).

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 1180-2021_English be delivered?

Answer: Upon your order, we will start to translate JJG 1180-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 1180-2021_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 1180-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.