US$419.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 111-2019: Clinical Thermometers Status: Valid JJG 111: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 111-2019 | English | 419 |
Add to Cart
|
4 days [Need to translate]
|
Clinical Thermometers
| Valid |
JJG 111-2019
|
JJG 111-2003 | English | 599 |
Add to Cart
|
3 days [Need to translate]
|
Verification Regulation of Clinical Thermometers
| Obsolete |
JJG 111-2003
|
JJG 111-2002 | English | RFQ |
ASK
|
3 days [Need to translate]
|
Railway rolling stock wheel diameter special measuring tools VRof
| |
JJG 111-2002
|
JJG 111-1989 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Verification Regulation of Clinical Thermometer
| Obsolete |
JJG 111-1989
|
JJG 111-1979 | English | RFQ |
ASK
|
3 days [Need to translate]
|
(Chinese Industry Standard)
| Obsolete |
JJG 111-1979
|
PDF similar to JJG 111-2019
Basic data Standard ID | JJG 111-2019 (JJG111-2019) | Description (Translated English) | Clinical Thermometers | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A54 | Classification of International Standard | 17.200 | Word Count Estimation | 18,195 | Date of Issue | 2019 | Date of Implementation | 2020-03-31 | Issuing agency(ies) | State Administration for Market Regulation |
JJG 111-2019: Clinical Thermometers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Clinical Thermometers
National Measurement Verification Regulations of the People's Republic of China
Glass thermometer
Published on December 31,.2019
2020-03-31 Implementation
Issued by the State Administration of Market Supervision and Administration
Verification Regulation of Glass Thermometer
Replace JJG 111-2003
Centralized unit. National Temperature Measurement Technical Committee
Main drafting unit. Shandong Institute of Metrology
Beijing Academy of Metrology and Testing Science
Participated in the drafting unit. Jinan Changfeng Zhiyuan Instrument Technology Co., Ltd.
Shanghai Institute of Metrology and Testing Technology
Anhui Institute of Metrology
People's Liberation Army General Hospital
East Aahua Medical Technology Co., Ltd.
This regulation is entrusted to the National Temperature Measurement Technical Committee for interpretation
The main drafters of this regulation.
Dong Rui (Shandong Institute of Metrology)
Yao Min (Beijing Institute of Metrology and Testing Science)
Participating drafters.
Zhang Jiong (Jinan Changfeng Zhiyuan Instrument Technology Co., Ltd.)
Yao Lifang (Shanghai Institute of Metrology and Testing Technology)
He Xiaohui (Anhui Institute of Metrology)
Zhou Juan (Chinese People's Liberation Army General Hospital)
Wang Weijian (Dong Aa Hua Medical Technology Co., Ltd.)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2 References (1)
3 Terminology (1)
3.1 Scale (1)
3.2 Scale line (1)
3.3 Scale value (1)
3.4 Scale board (1)
3.5 Interrupt (1)
3.6 Gravity (1)
3.7 Difficult to throw (1)
4 Overview (2)
4.1 Principle (2)
4.2 Type (2)
4.3 Uses (2)
5 Measurement performance requirements (2)
6 General technical requirements (2)
6.1 Scales and signs (2)
6.2 Glass rod and glass sleeve (3)
6.3 Internal standard thermometer scale plate (3)
6.4 The tip of the thermometer (3)
6.5 Temperature-sensing bubble (3)
6.6 Temperature sensing fluid (3)
6.7 Temperature sensitive liquid column (3)
7 Control of measuring instruments (3)
7.1 Verification conditions (3)
7.2 Verification items (4)
7.3 Verification method (5)
7.4 Verification data processing (7)
7.5 Processing of verification results (8)
7.6 Verification period (8)
Appendix A Verification Method of Multi-branched Thermometer (9)
Appendix B Format of the inner pages of the certificate of verification or verification result (10)
Appendix C. Reference Format for Verification Records of Glass Thermometers (11)
Appendix D Centrifuge speed calculation formula (13)
Introduction
JJF1001-2011 "General Measurement Terms and Definitions", JJF1007-2007 "Temperature Measurement Terms and Definitions
"Yi" and "JJF1002-2010" Rules for the Compilation of National Metrology Verification Regulations "together constitute the supporting work for the revision of this regulation
Basic norms.
This regulation refers to OIMLR7.1979 (E) "(Mercury glass with the highest retention point structure) thermometer"
Revise the relevant content such as gauge type, scale, maximum allowable error, etc.
This regulation replaces the verification procedure of JJG 111-2003 "Glass Thermometer", and JJG 111-2003 "Glass Body"
Compared with the Thermometer, the main technical changes except for editorial changes are as follows.
--- Add the second-class standard platinum resistance thermometer as an optional standard;
--- Improved the technical requirements of the constant temperature bath;
--- Added check in use;
--- Deleted some verification items;
--- Modified the method of judging the result of indication error;
--- Added a description of the method for simultaneously verifying multi-branch thermometers.
Previous releases of this regulation.
--- JJG 111-2019;
--- JJG 111-2003;
--- JJG 111-1989.
Verification Regulation of Glass Thermometer
1 Scope
This verification procedure is applicable to the measurement range of 30.0 ℃ ~ 43.0 ℃, with the highest retention point structure, the temperature sensitive medium is
Liquid glass thermometer (hereinafter referred to as thermometer) for the first verification and inspection in use.
2 Reference documents
This regulation refers to the following documents.
JJG 160 standard platinum resistance thermometer
JJG 881 standard thermometer
JJF1007-2007 Temperature measurement terms and definitions
GB 1588 glass thermometer
For dated references, only the dated versions are applicable to this Regulation; for those without dates
The latest version (including all amendments) is applicable to this regulation.
3 Terminology
The following terms and definitions defined in JJF1007-2007 "Terms and Definitions of Temperature Measurement Terms" and the following apply to this
procedure.
3.1 Scale
A combination of a set of lines, numbers, and unit of measurement symbols (° C) on the thermometer, used to indicate temperature, also known as
Scale.
3.2 Scale line
The line engraved on the glass rod or scale plate to indicate the temperature value is also called the scale line.
3.3 scale value
The number printed on the glass rod or scale plate to indicate the temperature value is also called the scale value.
3.4 scaleplate
Straight, colored (e.g. milky white) thin, engraved scale lines, scale values and other symbols in the internal standard thermometer
Piece, also called scale plate.
3.5 Interrupt liquidcolumngap
The liquid column of the thermometer is disconnected above the retention point structure.
3.6 Self-liquid liquid column receding solely
The phenomenon that the temperature-sensing liquid column of the thermometer retracts toward the temperature-sensing bubble on the part above the retention point structure.
3.7 Liquidcolumnrecedingdifficultly
Under a certain external force, it is difficult for the temperature sensing liquid column of the thermometer to retract from above the minimum temperature scale line to the minimum temperature scale
The phenomenon below the degree line.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 111-2019_English be delivered?Answer: Upon your order, we will start to translate JJG 111-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 111-2019_English with my colleagues?Answer: Yes. The purchased PDF of JJG 111-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 111-2019?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 111-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|