US$439.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 1087-2013: Verification Regulation of Oxygen Alarm Detectors for Mining Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 1087-2013 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
Verification Regulation of Oxygen Alarm Detectors for Mining
| Valid |
JJG 1087-2013
|
PDF similar to JJG 1087-2013
Basic data Standard ID | JJG 1087-2013 (JJG1087-2013) | Description (Translated English) | Verification Regulation of Oxygen Alarm Detectors for Mining | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A61 | Classification of International Standard | 17.020 | Word Count Estimation | 19,177 | Regulation (derived from) | AQSIQ Announcement No. 114, 2013; | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to: the mine operating environment measuring range of oxygen mole fraction (0 to 25) % electrochemical principles Mine oxygen detection alarm (hereinafter referred to as instrumentation) initial verification, testing and use of the f |
JJG 1087-2013: Verification Regulation of Oxygen Alarm Detectors for Mining---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Oxygen Alarm Detectors for Mining
State verification procedures People's Republic of China
Mining oxygen detection alarm
Issued on. 2013-08-15
2013-11-15 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Mining oxygen detection alarm
Verification Regulation
Focal point. the National Technical Committee on Environment stoichiometry
The main drafting units. National Mine Safety metering station
Participated in the drafting unit. Chongqing national production mining equipment inspection and testing center security
National Coal Mine Safety dust ventilation product quality supervision and inspection center
Huainan Run Technology Co., Ltd.
Chongqing Ke Electronic Co., Ltd.
This procedure commissioned the National Technical Committee of the stoichiometric environment responsible for interpreting
The main drafters of this procedure.
Chen Fumin (National Mine Safety metering station)
Drafters participate.
Cao Libo (national safety Chongqing mining equipment testing centers)
Fujian Tao (National Coal Mine Safety dust ventilation product quality supervision and inspection center)
Sun Chao (Huainan-Run Technology Co., Ltd.)
Shifa Jiang (National Mine Safety metering station)
Zhang Enron (National Mine Safety metering station)
David Chiu (Chongqing Ke Electronic Co., Ltd.)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2 Overview (1)
3 metering performance requirements (1)
3.1 indication error (1)
3.2 Repeatability (1)
3.3 Response Time (1)
3.4 Drift (1)
4 General Requirements (1)
4.1 Appearance and structure (1)
4.2 Signs and identification (1)
4.3 energizing check (1)
4.4 Alarm function (2)
4.5 Signal transmission error (2)
4.6 Insulation Resistance (2)
5 control of measuring instruments (2)
5.1 verification Conditions (2)
5.2 Verification Project (3)
5.3 Verification Methods (3)
5.4 Verification Results Processing (6)
5.5 test cycle (6)
Appendix A Portable/Stationary oxygen mine detection alarm verification original records table (7)
Appendix B test certificates/test results in the notice page format (11)
Introduction
This procedure based on JJF1002 "national verification procedures write rules", JJF1001 "common terminology and measurement
The definition of "compilation.
Since the mine with oxygen detection alarm with oxygen detection alarm used in terrestrial environment, technical specifications, instrument
There is a big difference on the status quo and so on, so this procedure the major technical indicators reference MT704-2008 "coal mine
With portable electrochemical oxygen measuring device ", MT447-1995" Mine electrochemical oxygen sensor technology stripe formula
Member ", JJG (coal) 10-1998" Oxygen Detection "and other technical regulations.
This procedure is the first release.
Mining oxygen detection alarm verification procedures
1 Scope
The order applies to the mine operating environment used in the measurement range of the oxygen mole fraction (0 to 25)% of electrochemical
Mine initial verification principle with oxygen detection alarm (hereinafter referred to as the instrument), the verification and subsequent use of checks.
2 Overview
Instrument for detecting the concentration of oxygen in the mine operating environment, when the oxygen concentration measurement is less than equal to the alarm value
It can automatically send out audible and visual alarm signal.
Apparatus main electrochemical oxygen sensing element, the electronic components and the display section, etc., is detected by an electrochemical oxygen
Element converts ambient oxygen concentration in the air into electrical signals, then processed by the circuit, and to show the concentration
To some instrument also has an oxygen concentration corresponding electrical signal output.
Depending on the use of the instrument can be divided into portable (mining industry, commonly referred to as alarm or measuring)
And fixed (mining industry, commonly called a sensor).
3 metering performance requirements
3.1 Indication error
Indication error of mole fractions of, shall not exceed ± 0.7%.
3.2 Repeatability
The relative standard deviation of ≤1.0%.
3.3 Response Time
Response time ≤60s.
3.4 Drift
Zero drift and span drift more than indication error should not be one-half.
4 General technical requirements
4.1 Appearance and structure
4.1.1 Each instrument mechanical adjustment member should be able to operate normally should be no loose fasteners.
4.1.2 The instrument shall not affect their normal work and explosion safety of injury, new manufacturing coatings should not have obvious Yen
Color unevenness and peeling, the components should be smooth junction.
4.2 Signs and identification
4.2.1 The instrument shall indicate the name and instrument manufacturing units name, model, serial number, date of manufacture, proof mark
And the number of mine safety signs and numbers.
4.2.2 The instrument shall specify the measurement range, the measurement error and other major technical indicators nameplate.
4.3 energizing check
After the instrument is powered, should be able to work properly, the display portion should be clear and complete. Each key shall be able to operate and control
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 1087-2013_English be delivered?Answer: Upon your order, we will start to translate JJG 1087-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 1087-2013_English with my colleagues?Answer: Yes. The purchased PDF of JJG 1087-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|