HOME   Cart(6)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJG 1071-2011 English PDF

US$629.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 1071-2011: Verification Equipment of Linear Accelerometer by Earths Gravitation
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 1071-2011English629 Add to Cart 5 days [Need to translate] Verification Equipment of Linear Accelerometer by Earths Gravitation Valid JJG 1071-2011

PDF similar to JJG 1071-2011


Standard similar to JJG 1071-2011

JJF 1234   JJF 1396   JJF 1071   JJG 1076   JJG 1074   

Basic data

Standard ID JJG 1071-2011 (JJG1071-2011)
Description (Translated English) Verification Equipment of Linear Accelerometer by Earths Gravitation
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A57
Classification of International Standard 17.080
Word Count Estimation 27,281
Date of Issue 2011-09-14
Date of Implementation 2011-12-14
Quoted Standard GJB 585A; GJB 1801-1993
Regulation (derived from) AQSIQ Announcement No. 134 of 2011
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies in the gravitational field precision indexing method based on linear accelerometer calibration device for the first time test, follow-up testing and use of checks.

JJG 1071-2011: Verification Equipment of Linear Accelerometer by Earths Gravitation

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Equipment of Linear Accelerometer by Earth "s Gravitation State verification procedures People's Republic of China Linear accelerometers verification equipment (gravitational field method) Gravitation Issued on. 2011-09-14 2011-12-14 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Linear accelerometers verification equipment (Gravitational field method) test procedures AccelerometerbyEarth ' sGravitation The regulations by the State Administration of Quality Supervision, Inspection and Quarantine on September 14, 2011, approved and since From December 14, 2011 implementation. NFP. National Technical Committees Inertial Measurement Technology The main drafting units. China Aviation Industry Corporation Beijing Great Wall Measurement and Testing Technology Institute The study Participated in the drafting unit. China North Industries Group Corporation ○ San Institute China Air to Air Missile Research Institute Corporation aviation industry This procedure Inertial Technology commissioned the National Technical Committee responsible for the interpretation of measurement The main drafters of this procedure. Dongxue Ming (China Aviation Industry Corporation Beijing Great Wall Institute of Measurement and Testing Technology) Xiong Lei (China Aviation Industry Corporation Beijing Great Wall Institute of Measurement and Testing Technology) Ho Yi only (China Aviation Industry Corporation Beijing Great Wall Institute of Measurement and Testing Technology) Drafters participate. Yu Xiaowei (China North Industries Group Corporation ○ San Institute) He Marine (China Aviation Industry Corporation Institute AAM)

table of Contents

1 Scope (1) 2. References (1) 3 Terms (1) 4 Overview (1) 4.1 Composition and principles (1) 4.2 Purpose (2) 5 metering performance requirements (2) 6 General Requirements (3) 6.1 appearance requirements and accessories (3) 6.2 Other technical requirements (3) 7 control of measuring instruments (3) 7.1 test conditions (3) 7.2 Verification Project (4) 7.3 Verification Methods (5) 7.4 test results processing (12) 7.5 test cycle (12) Appendix A Measurement Uncertainty instance (13) B angular position of the positioning error calculation example direct assay appendix (15) Appendix C angular position of the positioning repeatability test calculation example (16) Appendix D test original record format (17) Appendix E test certificate-page format (21) Appendix F test results in the notice page format (22) Linear accelerometers verification equipment (gravitational field method) test procedures

1 Scope

This procedure is applied in a gravitational field line accelerometer initial verification verification device based precision indexing method, follow-up Verification and use of checks. 2. References GJB585A inertial technology terms The main performance test methods GJB1801-1993 inertial technology test equipment For dated references, only the dated edition applies to this procedure; undated reference documents Member, the latest edition (including any amendments) applies to this procedure.

3 Terms

The following terms and definitions apply to this procedure. 3.1 linear accelerometer calibration device (gravitational field method) verificationequipmentoflinearaccelerometer byearth'sgravitation The use of gravity in the gravitational field being accelerometer input axis component of the subject line, test line accelerometer Device performance parameters. 3.2 precision indexing means precisiondigitialdividingequipment Angle precision can be given subject accelerometer input axis direction means the direction of gravity. Zero zeroofprecisiondigitialdividingequipment 3.3 precision indexing device Mounting means on the vertical axis of rotation is normal inspection jig accelerometer mounting surface and precision indexing, and the mounting surface Parallel to the horizontal plane normal to the axis of rotation precision indexing device determined while the subject is placed at the axis accelerometer When the indication precision indexing means in the same plane. 3.4 jig horizontal mounting error mountingerroroffixtureinhorizontaldirection When precision indexing means is zero, the installation was seized accelerometer mounting surface and the mounting fixture on the horizontal plane, in The angle between the vertical plane precision indexing means on the axis of rotation. 3.5 clamp vertical misalignment mountingerroroffixtureinverticaldirection When precision indexing means is zero, the installation was seized accelerometer mounting surface and the mounting fixture on the horizontal plane, in Precision indexing means rotation axis and the angle between the direction of gravity on the plane OK.

4 Overview

4.1 Composition and principle 4.1.1 Composition Linear accelerometers verification equipment (gravitational field method) (hereinafter referred to as the "means test") including precision indexing means electricity Sub-level (or photoelectric autocollimator), mounting fixtures (hereinafter referred to as "clamp") and the electrical connections and power,

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 1071-2011_English be delivered?

Answer: Upon your order, we will start to translate JJG 1071-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 1071-2011_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 1071-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.