Verification Regulation of Low-level Dissolved Oxygen Meters
| Valid |
JJG 1060-2010
|
PDF similar to JJG 1060-2010
Basic data | Standard ID | JJG 1060-2010 (JJG1060-2010) | | Description (Translated English) | Verification Regulation of Low-level Dissolved Oxygen Meters | | Sector / Industry | Metrology & Measurement Industry Standard | | Classification of Chinese Standard | A61 | | Classification of International Standard | 17.020 | | Word Count Estimation | 19,163 | | Date of Issue | 2010-09-06 | | Date of Implementation | 2010-12-06 | | Quoted Standard | DL/T 1002-2006; ASTM D5462-2008; ASTM D5543-2009 | | Regulation (derived from) | AQSIQ Announcement No. 100 of 2010 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | | Summary | This standard applies to polarographic type of trace oxygen analyzer initial verification, testing and use of follow-up inspection. |
JJG 1060-2010: Verification Regulation of Low-level Dissolved Oxygen Meters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Low-level Dissolved Oxygen Meters
State verification procedures People's Republic of China
Trace Dissolved Oxygen Meter
Issued on. 2010-09-06
2010-12-06 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Trace Dissolved Oxygen Meter Verification Regulation
enMeters
The regulations by the State Administration of Quality Supervision, Inspection and Quarantine approved on September 6, 2010, and from
From December 6, 2010 into effect.
Focal point. the National Technical Committee stoichiometric physical
The main drafting units. China Institute of Metrology
Guangxi Academy of measuring and testing
Participated in the drafting unit. Jiangsu, days Power Technology Co.,
12th Research Institute of China Electronics Technology Group
This procedure commissioned the National Technical Committee of the stoichiometric physics responsible for the interpretation
The main drafters of this procedure.
Repair Hongyu (China Institute of Metrology)
Rong Feng can (Guangxi Institute of measurement detection)
Drafters participate.
Gong Dongyu (Jiangsu Power Technology Co., Ltd., days)
Ji Chun-feng (12th Research Institute of China Electronics Technology Group)
table of Contents
1 Scope (1)
2. Referenced Documents (1)
3 Terms (1)
4 Overview (1)
5 metering performance requirements (2)
6 General Requirements (2)
6.1 Appearance (2)
6.2 Dissolved Oxygen Sensor (2)
7 control of measuring instruments (3)
7.1 test conditions (3)
7.2 test items and test methods (3)
7.3 Verification Results Processing (5)
7.4 test cycle (5)
Uncertainty Principle and Evaluation (6) Appendix A Faraday standard water electrolysis oxygen generating apparatus
B oxygen-free water preparation method Appendix (9)
C pure water saturated dissolved oxygen concentration appendix (10)
Appendix D test original record format (11)
Appendix E test certificate-page format (13)
Appendix F test results in the notice page format (14)
Trace Dissolved Oxygen Meter Verification Regulation
1 Scope
The order applies to polarographic type trace oxygen analyzer initial verification, subsequent verification and in-service inspection.
2 Citations
The regulations cited in the following documents.
DL/T 1002-2006 Trace Dissolved Oxygen meter Calibration standard gas calibration method ---
ASTMD5462-2008 StandardTestMethodforOn-lineMeasurementofLow-level
DissolvedOxygeninWater (Trace oxygen line measurement standard
Standard Test Method)
ASTMD5543-2009 StandardTestMethodsforLow-levelDissolvedOxygenin
Water (Standard Test Method for Trace Dissolved Oxygen)
When using this procedure, it should pay attention to using the currently valid version of the documents cited.
3 Terms
3.1 Anaerobic water zerodissolved-oxygen (DO) water
Oxygen-free water. Dissolved Oxygen meter is usually used for zero calibration.
3.2 oxygen bottom water backgrounddissolved-oxygen (DO) water
This refers to the standard bottom oxygen dissolved oxygen generator did not produce oxygen, the residual dissolved oxygen testing circuit, through
Commonly used to evaluate the test circuit tightness and barrier. The bottom oxygen water test loop refers dissolved oxygen of the water bottom.
3.3 standard oxygen water standarddissolved-oxygen (DO) water
Dissolved oxygen standard refers to a standard means for generating standard DO happen. Standard oxygen water test loop refers to a solution
Standard oxygen water.
4 Overview
Trace oxygen analyzer is widely used in electrical, electronic, chemical and other industries measured dissolved oxygen concentration of process water
Amount, usually by the DO sensor (or oxygen sensor) and an electronic unit (or secondary instrument) components. Polarographic
Type trace oxygen analyzer (hereinafter referred to as instruments) electrochemical Polarographic sensor 0 ~ 100μg · L-1
Dissolved oxygen in the range, which works as follows. cathodic polarographic sensors usually gold or platinum, multi-anode
Silver (also other metals such as lead), a selective oxygen permeable membrane permeable to oxygen. When a water sample flows through the oxygen sensor,
Water samples in oxygen to diffuse through the membrane selective gas permeable membrane, under the effect of dissolved oxygen molecules in the polarization voltage is dissolved
Reducing the oxygen sensor to generate a response current. At a certain temperature, in response to the current size of the dissolved oxygen concentration was positively
ratio. In response to the current through the data processing showed dissolved oxygen concentration on the display.
On the cathode, oxygen is reduced to hydroxide.
O2 2H2 → O 4e 4OH-
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 1060-2010_English be delivered?Answer: Upon your order, we will start to translate JJG 1060-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 1060-2010_English with my colleagues?Answer: Yes. The purchased PDF of JJG 1060-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|