Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 1042-2008English489 Add to Cart 4 days [Need to translate] Verification Regulation for Ambulatory Electrocardiographs Valid JJG 1042-2008
JJG 1042-1993EnglishRFQ ASK 3 days [Need to translate] Technical Specification of Measurement Assurance Program for DC EMF Obsolete JJG 1042-1993

PDF similar to JJG 1042-2008


Standard similar to JJG 1042-2008

JJF 1234   JJF 1396   JJG 376   JJF 2016   JJG 1043   JJG 1041   

Basic data

Standard ID JJG 1042-2008 (JJG1042-2008)
Description (Translated English) Verification Regulation for Ambulatory Electrocardiographs
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A56
Classification of International Standard 17.220
Word Count Estimation 21,272
Date of Issue 2008-04-23
Date of Implementation 2008-07-23
Regulation (derived from) ?AQSIQ Announcement 2008 No.45
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to the type evaluation cold water, initial verification, follow-up tests and in-service inspection. The procedures referred to in cold water to measure flow through closed conduits clean cold water, temperature rating of T30 or T50 meter, including mechanical meter, equipped with a mechanical meter electronic devices, meter working on the principle of electromagnetic or electronic.

JJG 1042-2008: Verification Regulation for Ambulatory Electrocardiographs

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation for Ambulatory Electrocardiographs State verification procedures People's Republic of China Dynamic (movable) ECG machine Posted 2008-04-23 2008-07-23 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Dynamic (movable) ECG machine Verification Regulation hs The regulations by the State Administration of Quality Supervision, Inspection and Quarantine approved on April 23, 2008, and from From July 23, 2008 into effect. Focal point. the National Radio Technical Commission metering The main drafting units. People's Liberation Army medical electromagnetic metering station China Institute of Metrology Participated in the drafting unit. Measurement and Testing Institute of Inner Mongolia Autonomous Region Space Medical Engineering Institute This procedure commissioned the National Radio Technical Commission responsible for the interpretation of measurement The main drafters of this procedure. Jia Jiange (People's Liberation Army medical electromagnetic metering station) Xue Li Yong (People's Liberation Army medical electromagnetic metering station) He Zhao (China Institute of Metrology) Drafters participate. Ning Quan (Inner Mongolia Metrology Institute) Fuxiang Ping (Space Medical Engineering Institute) Ye Hongmei (Space Medical Engineering Institute)

table of Contents

1 Scope (1) 2 Terms and definitions (1) 3 Overview (1) 4 metering performance requirements (1) 4.1 Maximum input range (1) 4.2 tracings minimum sensitivity threshold (2) 4.3 Resistance polarization voltage (2) 4.4 Input impedance (2) 4.5 Sensitivity error (2) 4.6 sensitivity stability (2) 4.7 Calibration voltage (applies only to analog memory device to be examined) (2) 4.8 Frequency Response (2) 4.9 overshoot (2) 4.10 lag (2) 4.11 timing error (only applicable to the event insertion means to be examined on a recorder) (2) 4.12 hard copy (printout or photo) tracings speed error (2) Interference between 4.13 (2) 4.14 common mode rejection ratio (2) 4.15 system noise level (2) 4.16 compliance and pacing pulse detection capability (2) 5 General technical requirements (3) 6 Control of measuring instruments (3) 6.1 Verification condition (3) 6.2 Verification Project (4) 6.3 Verification Methods (5) Processing 6.4 Verification Results (12) 6.5 test cycle (12) Appendix A test recording format (13) Appendix B calibration certificate with test results in the notice page format (16) Dynamic (movable) EKG test procedures

1 Scope

The order applies to the following two types of dynamic (movable) electrocardiograph initial verification, subsequent verification and make With the test. a) continuous recording, analysis and electrocardiogram achieve full playback. It may be recorded after storage back to the stand-alone workstation Caving or recorded, analyzed simultaneously. b) continuous analysis but only a part of the record, does not provide full playback. This procedure does not apply to not provide continuous analysis of intermittent event recorders.

2 Terms and definitions

2.1 ECG electrocardiogram (ECG) Cardiac potential visual record. 2.2 dynamic (movable) ECG machine ambulatoryelectrocardiographs (AECG) By the portable recording and playback apparatus composed of either should have analytical capabilities. 2.3 portable recorder (recorder) ambulatoryrecorder (recorder) By the ECG recording device carried by patients, the ECG electrodes connected to the line for long-time recording or recording and sub Analysis of ECG of the patient. 2.4 playback device playbackequipment Mobile recording stores data for display (or analysis) and text processing apparatus.

3 Overview

Dynamic (movable) ECG machine can continuously for 24 hours or more records in the patient's natural state tee Channel or multi-channel ECG signal by means of a computer for display, analysis and processing, and found all kinds of arrhythmic events ST segment abnormalities, provide an important basis for clinical diagnosis and treatment. Dynamic (movable) ECG machine is usually divided into two types. 1) for continuous recording and analysis Dynamic ECG a) conventional dynamic electrocardiogram machine, the first recording ECG signals, and then by an independent workstation for analysis and processing; b) real-time dynamic ECG, recorded and analyzed simultaneously. 2) Continuous analysis but some dynamic ECG recording type a) In the course of the entire ECG only on important events or specific ECG recording; b) in the whole process of real ECG recording ECG, but only time and generate reports to amplitude compression formats.

4 metering performance requirements

4.1 Maximum input range Subject dynamic (movable) ECG machine (hereinafter referred to as the subject device), each channel should be able to respond and show

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 1042-2008_English be delivered?

Answer: Upon your order, we will start to translate JJG 1042-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 1042-2008_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 1042-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 1042-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 1042-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.