HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJG 1035-2022 English PDF

US$329.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 1035-2022: Optical Spectrum Analyzers in Telecommunication
Status: Valid

JJG 1035: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 1035-2022English329 Add to Cart 3 days [Need to translate] Optical Spectrum Analyzers in Telecommunication Valid JJG 1035-2022
JJG 1035-2008English559 Add to Cart 3 days [Need to translate] Verification Regulation of Optical Spectrum Analyzers in Telecommunication Obsolete JJG 1035-2008
JJG 1035-1992EnglishRFQ ASK 3 days [Need to translate] Metrological Terms and Their Definitions for Ionizing Radiation Obsolete JJG 1035-1992

Standard similar to JJG 1035-2022

JJF 1033   JJF 1050   JJF 1030   

Basic data

Standard ID JJG 1035-2022 (JJG1035-2022)
Description (Translated English) Optical Spectrum Analyzers in Telecommunication
Sector / Industry Metrology & Measurement Industry Standard
Word Count Estimation 15,180
Date of Issue 2022-06-28
Date of Implementation 2022-12-28
Issuing agency(ies) State Administration for Market Regulation

JJG 1035-2022: Optical Spectrum Analyzers in Telecommunication

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Optical Spectrum Analyzers in Telecommunication National Metrology Verification Regulations of the People's Republic of China Communication Spectrum Analyzer Released on 2022-06-28 2022-12-28 Implementation Released by the State Administration for Market Regulation Communication Spectrum Analyzer Verification Regulations Replace JJG 1035-2008 Responsible unit. National Optical Metrology Technical Committee Main drafting unit. China Institute of Metrology National Communication Metering Station Participating in the drafting unit. China Jiliang University Shaanxi Institute of Metrology Wuxi Metrology and Testing Institute This regulation entrusts the National Optical Metrology Technical Committee to be responsible for interpretation The main drafters of this regulation. Xu Nan (National Institute of Metrology) Li Jian (National Institute of Metrology) Zhang Yingyan (National Communications Metrology Station) Wang Yangyang (National Institute of Metrology, China) Participating drafters. Gong Huaping (China Jiliang University) Li Rong (Shaanxi Institute of Metrology) Wang Guanjun (Wuxi Metrology and Testing Institute)

Table of contents

Introduction (Ⅱ) 1 Scope(1) 2 References(1) 3 Overview(1) 4 Metrological performance requirements (2) 4.1 Wavelength(2) 4.2 Optical Power(2) 5 General technical requirements (2) 5.1 Appearance(2) 5.2 Optical system(2) 6 Measuring Instrument Control(2) 6.1 Test conditions (2) 6.2 Verification items (3) 6.3 Verification method (3) 7 Processing of test results (6) 8 test cycles(6) Appendix A Verification Original Record Format (7) Appendix B Format of the inner page of the verification certificate (9)

Introduction

JJF1002 "Rules for Writing National Metrology Verification Regulations", JJF1001 "General Metrology Terms and Definitions", JJF1059.1 "Assessment and Expression of Measurement Uncertainty" together constitute the basic series of specifications for the revision of this regulation. This regulation is a revision of JJG 1035-2008 "Spectrum Analyzer for Communication". Compatible with JJG 1035-2008 In addition to editorial modifications, the main technical changes are as follows. --- Deleted the limitation on the wavelength range; --- Properly relax the measurement uncertainty requirements of the main standard optical wavelength meter according to actual needs; --- Simplified the measurement steps of resolution bandwidth and the expression of measurement results; ---Increase the error of the indication value of the wavelength measured by the beam splitter method, and reduce the measurement uncertainty caused by the change of the wavelength of the light source; ---Optical power indication and nonlinear verification of the optical spectrum analyzer directly refer to JJG 813 "Fiber Optic Optical Power Meter" implement; --- The verification requirements for polarization-dependent loss are deleted. The previous releases of this regulation are as follows. ---JJG 1035-2008. Verification Regulations for Optical Spectrum Analyzer for Communication

1 Scope

This regulation applies to the initial verification, follow-up verification and Check in use.

2 References

This procedure references the following documents. JJG 813 Fiber Optic Power Meter IEC 62129-1 Calibration of wavelength/optical frequency measuring equipment Part 1.Optical spectrum analyzer (Calibration analyzers) For dated references, only the dated version applies to this regulation; for undated references document, its latest version (including all amendments) applies to this regulation.

3 Overview

A spectrum analyzer is a measuring instrument used to measure the spectral power distribution of an optical signal. Optical spectrum analyzers can measure light sources It can also measure the spectral transmission characteristics of some passive devices. At present, there are two main measurement methods for spectrum analyzers. grating method and interferometry. The main advantage of the grating method is that the scanning The scanning speed is fast and the cost is low. The schematic structure of the grating spectrum analyzer is shown in Figure 1.The main advantage of interferometry is that the wavelength The test accuracy is high, but the dynamic range is limited, the scanning speed is slow, and the cost is high. Schematic diagram of the structure of the interferometric spectrum analyzer as shown in picture 2. Fig.1 Schematic diagram of grating spectrum analyzer