US$319.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1812-2020: Calibration Specification for Apparatus to Measure Water Permeability of Concrete Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1812-2020 | English | 319 |
Add to Cart
|
3 days [Need to translate]
|
Calibration Specification for Apparatus to Measure Water Permeability of Concrete
| Valid |
JJF 1812-2020
|
PDF similar to JJF 1812-2020
Basic data Standard ID | JJF 1812-2020 (JJF1812-2020) | Description (Translated English) | Calibration Specification for Apparatus to Measure Water Permeability of Concrete | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A53 | Classification of International Standard | 17.100 | Word Count Estimation | 14,162 | Date of Issue | 2020 | Date of Implementation | 2020-04-17 | Issuing agency(ies) | State Administration for Market Regulation |
JJF 1812-2020: Calibration Specification for Apparatus to Measure Water Permeability of Concrete ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Calibration specification for concrete impermeability tester)
National Metrology Technical Specifications of the People's Republic of China
Calibration Specification for Concrete Impermeability Tester
2020-01-17 released
2020-04-17 implementation
Issued by the State Administration for Market Regulation
Calibration Specification for Concrete Impermeability Tester
Focal point. National Pressure Measurement Technical Committee
Main drafting unit. Yunnan Institute of Metrology and Testing Technology
Participating in the drafting. Guangdong Institute of Metrology
Fujian Institute of Metrology
Xinjiang Uygur Autonomous Region Metrology and Testing Institute
Jilin Institute of Metrology
This specification entrusts the National Pressure Measurement Technical Committee to be responsible for interpretation
The main drafters of this specification.
Chang Xuan (Yunnan Institute of Metrology and Testing Technology)
Zhang Shaowang (Yunnan Institute of Metrology and Testing Technology)
Participating drafters.
Xu Biao (Guangdong Institute of Metrology)
Lin Jingxing (Fujian Institute of Metrology)
Zeng Sudi (Yunnan Institute of Metrology and Testing Technology)
Zhuo Hua (Xinjiang Uygur Autonomous Region Metrology and Testing Research Institute)
Zhang Panfeng (Jilin Institute of Metrology)
table of Contents
Introduction (Ⅱ)
1 scope (1)
2 Reference documents (1)
3 Overview (1)
4 Measurement characteristics (2)
4.1 Pressure indication error (2)
5 Calibration conditions (2)
5.1 Environmental conditions (2)
5.2 Measurement standards (2)
6 Calibration items and calibration methods (2)
6.1 Functional inspection (2)
6.2 System leak check (2)
6.3 Pressure indication error (3)
7 Calibration results (3)
7.1 Calibration data processing (3)
7.2 Calibration certificate (3)
7.3 Evaluation of calibration uncertainty (3)
8 Recalibration interval (3)
Appendix A Impermeability Meter Calibration Record Format (4)
Appendix B Internal page format of calibration certificate (5)
Appendix C Uncertainty Evaluation Example of Pressure Indication Calibration (7)
Introduction
This specification is based on JJF 1071-2010 "Rules for the Compilation of National Metrology and Calibration Specifications", JJF 1001-2011 "General
Measurement terms and definitions", JJF 1059.1-2012 "Evaluation and Expression of Measurement Uncertainty" and JJF 1094-2002
The "Quality Evaluation of Measuring Instruments" is a basic series of specifications.
This specification refers to JJG52-2013 "Elastic element type general pressure gauge, pressure vacuum gauge and vacuum gauge",
JJG875-2005 "Digital Pressure Gauge" and JG/T 249-2009 "Concrete Impermeability Tester" are compiled.
This specification is released for the first time.
Calibration Specification for Concrete Impermeability Tester
1 Scope
This specification applies to the calibration of concrete impermeability instruments with a measuring range of (0~4) MPa, as well as the calibration of mortar impermeability instruments.
2 Reference documents
This specification refers to the following documents.
JJG52-2013 elastic element type general pressure gauge, pressure vacuum gauge and vacuum gauge
JJG875 Digital Pressure Gauge
JG/T 249-2009 Concrete Impermeability Tester
For dated reference documents, only the dated version applies to this specification; for undated reference documents,
The latest version (including all amendments) is applicable to this specification.
3 overview
Concrete Impermeability Tester (hereinafter referred to as Impermeability Tester) is used to detect the waterproof performance of concrete after hardening, and to determine
Its impermeability marking measuring instrument. The impermeability meter applies Pascal's law, and the pressure at all points in the static sealed container is equal everywhere
The principle of (the water level difference is negligible), the whole system is pressurized with a water pump, and the pressure gauge and electrical controller are used to
The pressure is indicated and controlled to realize the penetration of water from bottom to top into the test piece press-fitted in the test mold to determine the test
The anti-permeability performance of the piece and the instrument to calculate its anti-permeability mark.
The impermeability instrument is composed of pressure control instruments, pressure sensors and other main measuring instruments, valves, and connecting pipelines, and is equipped with
There are 6 mold bases for installation and test molds. The impermeability instrument is pressurized by an electric plunger pump, and is connected to the water supply capacity through a hydraulic pipeline.
The pressure gauges and electrical control systems in the pipeline are connected to each pressure point of the anti-permeability instrument.
The adjustment control can make the impermeability tester perform a constant pressure test within the specified pressure range of (0.1~4) MPa. anti-
The 6 test mold bases included in the osmometer, the middle hole of each mold bottom is used as a water pressure output port, and each output port can enter
Line independent control and measurement. The structure of the impermeability instrument is shown in Figure 1.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1812-2020_English be delivered?Answer: Upon your order, we will start to translate JJF 1812-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1812-2020_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1812-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|