JJF 1803-2020: Calibration Specification for the Anthropomorphic Test Device (H-III Female) of Vehicle Frontal Impact Test
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1803-2020English719 Add to Cart 5 days [Need to translate] Calibration Specification for the Anthropomorphic Test Device (H-III Female) of Vehicle Frontal Impact Test Valid JJF 1803-2020

PDF similar to JJF 1803-2020


Standard similar to JJF 1803-2020

JJF 1943   GB/T 36126   GB/T 1885   JJF 1802   JJF 1810   JJF 1801   

Basic data

Standard ID JJF 1803-2020 (JJF1803-2020)
Description (Translated English) Calibration Specification for the Anthropomorphic Test Device (H-III Female) of Vehicle Frontal Impact Test
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A53
Classification of International Standard 17.160
Word Count Estimation 33,361
Date of Issue 2020
Date of Implementation 2020-04-17
Issuing agency(ies) State Administration for Market Regulation

JJF 1803-2020: Calibration Specification for the Anthropomorphic Test Device (H-III Female) of Vehicle Frontal Impact Test


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Calibration specification for humanoid test device (H-Ⅲ female) for frontal crash test of automobile) National Metrology Technical Specifications of the People's Republic of China Humanoid test device for automobile frontal collision test (H-Ⅲ Female) Calibration Specification 2020-01-17 released 2020-04-17 implementation Issued by the State Administration for Market Regulation Humanoid test device for automobile frontal collision test (H-Ⅲ Female) Calibration Specification AnthropomorphicTestDevice(H-ⅢFemale) ofVehicleFrontalImpactTest Focal point: National Technical Committee of Vibration and Shock Speed Measurement Main drafting unit: Shanghai Motor Vehicle Testing and Certification Technology Research Center Co:, Ltd: Shenzhen AVIC Technology Testing Institute Participated in the drafting: The 304th Research Institute of Aviation Industry Corporation of China This specification entrusts the National Technical Committee of Vibration and Shock Speed Measurement to be responsible for the interpretation The main drafters of this specification: Shen Yafei (Shanghai Motor Vehicle Testing and Certification Technology Research Center Co:, Ltd:) Wei Jufeng (Shenzhen AVIC Technology Testing Institute) Shen Li (Shanghai Motor Vehicle Testing and Certification Technology Research Center Co:, Ltd:) Participating drafters: Li Shanming (304th Research Institute of Aviation Industry Corporation of China) Peng Yu (Shanghai Motor Vehicle Testing and Certification Technology Research Center Co:, Ltd:) Xu Jianjie (Shanghai Motor Vehicle Testing and Certification Technology Research Center Co:, Ltd:)

table of Contents

Introduction (Ⅱ) 1 scope (1) 2 Reference documents (1) 3 Terms and definitions (1) 4 Overview (2) 5 General technical requirements and measurement characteristics (2) 6 Calibration conditions (2) 7 Calibration items and calibration methods (4) 8 Calibration result expression (14) 9 Re-calibration interval (15) Appendix A Calibration record content (16) Appendix B Inside page of calibration certificate (18) Appendix C H-Ⅲ Dimensions of female dummy (20) Appendix D H-Ⅲ Quality of Female Dummy Parts (22) Appendix E H-Ⅲ Example of Uncertainty Evaluation of Measurement of Head Acceleration Value of Female Dummy (23) Appendix F Calculation method of chest displacement sensitivity (26)

Introduction

This specification is based on JJF 1071 "Rules for Compilation of National Metrology and Calibration Specifications", JJF 1001 "General Metrology Terms and Definitions" ”, JJF 1059:1 “Evaluation and Expression of Measurement Uncertainty” as the basic specification for the formulation of calibration specifications, The technical standards refer to the US Federal Motor Vehicle Safety Standards (FMVSS) 49, Part 572, Human Type Test Equipment Set up test equipment" branch O: H-Ⅲ female dummy (FederalMotorVehicleSafetyStandards/T itle49 CFRPart 572\u003cANTHROPOMORPHICTESTDEVICES\u003e SubpartO:HybridⅢ5th PercentileFemaleTestDummy): This specification is aimed at the humanoid test equipment used in the frontal impact test of automobiles: The characteristics of the H-Ⅲ 5th percentile female test device were developed: This specification is released for the first time: Humanoid test device for automobile frontal collision test (H-Ⅲ Female) Calibration Specification

1 Scope

This specification is applicable to the mixed type III 5th percentile humanoid (female) test device (with Hereafter referred to as H-Ⅲ female dummy) calibration:

2 Reference documents

This specification refers to the following documents: JJF 1230 Calibration Specification for Humanoid Test Device for Frontal Impact Test of Automobile GB 11551 Occupant protection in frontal collision of automobile GB/T 20485:22 Vibration and shock sensor calibration method part 22: shock comparison method calibration ISO 6487:2012 Road vehicle crash test measurement technology equipment (Roadvehicles- Measurementtechniquesinimpacttests-Instrumentation) SAEJ211-1 Impact test instrument Part 1: Electronic instrument (InstrumentaionforImpact Test-Part 1ElectronicInstrumentation) SAEJ2517H-Ⅲ Family Chest Displacement Sensor Calibration Process (HybridⅢFamilyChestPoten- tiometerCalibrationProcedure) U:S: Federal Motor Vehicle Safety Standard (FMVSS) 49 Volume Part 572 Human Type Test Device Test Equipment Branch O: H-Ⅲ female dummy (FederalMotorVehicleSafetyStandards/T itle49CFRPart 572\u003cANTHROPOMORPHICTESTDEVICES\u003e SubpartO:HybridⅢ5thPercentile FemaleTestDummy) For dated reference documents, only the dated version applies to this specification; for undated references The latest version (including all amendments) is applicable to this specification:

3 Terms and definitions

3:1 Channel amplitude class channelamplitudeclass (CAC) The representation method of the data channel that meets the amplitude characteristics specified in the appendix of GB 11551, and the value is equal to the measurement range The upper limit: Note: Modified from Appendix D of GB 11551: 3:2 Channel frequency class channelfrequencyclass (CFC) Represented by a certain value, indicating that the frequency response of the channel is within the specified limit: Corresponding to the definition of CFC characteristic frequency For FH, set the corresponding CFC level according to different calibration items: Note: Modified from Appendix D of GB 11551: 3:3 time-zero The moment when the pendulum impact surface and the aluminum honeycomb impact surface are in initial contact, the time of all data channels at this time is defined as zero (That is, the time of all calibration parameters are uniformly set to zero):

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1803-2020_English be delivered?

Answer: Upon your order, we will start to translate JJF 1803-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1803-2020_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1803-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.