HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

JJF 1738-2019 English PDF

US$589.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1738-2019: Calibration Specification for the Upper Limit of Dynamic Range of High Sound Pressure Measuring Microphones
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1738-2019English589 Add to Cart 5 days [Need to translate] Calibration Specification for the Upper Limit of Dynamic Range of High Sound Pressure Measuring Microphones Valid JJF 1738-2019

PDF similar to JJF 1738-2019


Standard similar to JJF 1738-2019

GB/T 3222.2   GB/T 3222.1   JJG 188   JJF 1730   JJF 1731   JJF 1728   

Basic data

Standard ID JJF 1738-2019 (JJF1738-2019)
Description (Translated English) Calibration Specification for the Upper Limit of Dynamic Range of High Sound Pressure Measuring Microphones
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A59
Classification of International Standard 17.140
Word Count Estimation 27,239
Date of Issue 2019
Date of Implementation 2019-12-27
Issuing agency(ies) State Administration for Market Regulation

JJF 1738-2019: Calibration Specification for the Upper Limit of Dynamic Range of High Sound Pressure Measuring Microphones


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(High sound pressure measurement microphone dynamic range upper limit calibration specification) National Measurement Technical Specification of the People's Republic of China High sound pressure measurement microphone Dynamic range upper limit calibration specification 2019-09-27 release 2019-12-27 Implementation Issued by the State Administration of Market Supervision and Administration High sound pressure measurement microphone Dynamic range upper limit calibration specification Centralized unit. National Acoustic Metrology Technical Committee Drafting unit. Hunan Acoustic Instrument Control Technology Co., Ltd. Chinese Academy of Metrology Suzhou Integrated Calibration Testing and Certification Co., Ltd. Shenzhen Institute of Metrology and Quality Inspection Beijing Aerospace Metrology and Testing Technology Research Institute This specification is entrusted to the National Acoustic Metrology Technical Committee for interpretation Drafters of this specification. Liu Xiangheng (Hunan Acoustic Instrument Control Technology Co., Ltd.) He Longbiao (Chinese Academy of Metrology) Zhou Lunbin (Suzhou Integrated Calibration Testing and Certification Co., Ltd.) Niu Feng (Chinese Academy of Metrology) Guoqing Zhang (Shenzhen Institute of Metrology and Quality Inspection) Yan Lei (Beijing Institute of Aerospace Metrology and Testing Technology) Tan Jiateng (Hunan Acoustic Instrument Control Technology Co., Ltd.)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2 References (1) 3 Terms and units of measurement (1) 3.1 Terms and definitions (1) 3.2 Quantity and unit (1) 4 Overview (2) 5 Metrological characteristics (2) 5.1 linear error (2) 5.2 Total harmonic distortion (2) 5.3 Dynamic range upper limit (2) 6 Calibration conditions (2) 6.1 Environmental conditions (2) 6.2 Measurement standards and other equipment (2) 7 Calibration items and calibration methods (3) 7.1 Calibration items (3) 7.2 Measuring device (3) 7.3 Calibration method (4) 8 Expression of calibration results (6) 8.1 Calibration records (6) 8.2 Calibration data processing (6) 8.3 Calibration certificate (6) 8.4 Measurement uncertainty of calibration results (6) 9 Recalibration interval (7) Appendix A Content and format of calibration records (8) Appendix B Content and format of calibration certificate (10) Appendix C Examples of measurement uncertainty assessment (13)

Introduction

This specification is compiled according to the rules and format given in JJF 1071-2010 "Rules for Compiling National Measurement and Calibration Specifications" The measurement uncertainty is written in accordance with the requirements of JJF 1059.1-2012 "Assessment and Expression of Measurement Uncertainty". This specification is the first release. High sound pressure measurement microphone Dynamic range upper limit calibration specification

1 Scope

This specification is applicable to the dynamic range of capacitive high sound pressure measurement microphones whose upper limit of dynamic range does not exceed 171dB Calibration of linear and total harmonic distortion at the upper limit and nearby interval levels. Calibration of other types of high sound pressure measurement microphones is also Refer to this specification.

2 Reference documents

This specification refers to the following documents. JJF 1001-2011 General Measurement Terms and Definitions JJF 1034-2005 Acoustic measurement terms and definitions JJF 1059.1-2012 Evaluation and expression of measurement uncertainty GB/T 3947-1996 Acoustic terms For dated reference documents, only the dated version applies to this specification; for those without date references The latest version (including all amendments) is applicable to this specification.

3 Terms and units of measurement

3.1 Terms and definitions The following terms and definitions as defined in JJF 1001-2011, JJF 1034-2005 and JJF 1059.1-2012 Used in this specification. 3.1.1 Dynamic range The difference between the overload sound pressure level of the electroacoustic transducer for sound reception and the equivalent noise sound pressure level. [GB/T 3947-1996, definition 5.64]. 3.1.2 Upper limit of dynamic range The corresponding sound pressure level when the total harmonic distortion of the microphone output voltage is a specified value. 3.1.3 Total harmonic distortion totalharmonicdistortion The ratio of the root-mean-square root-mean-square value of all harmonics to the fundamental square-root-mean-square value. 3.1.4 Level linearity error When the sound pressure level changes within the linear range of the microphone at any frequency in the range of 160Hz to 1000Hz, it is transmitted The amount of change in the sensitivity level of the speaker. 3.1.5 Linearity range The linear error of the level does not exceed the range of the sound pressure level of the specified error limit. 3.2 Quantity and unit High sound pressure measurement microphone dynamic range upper limit and related measurement characteristic quantity and corresponding unit name and symbol as follows.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1738-2019_English be delivered?

Answer: Upon your order, we will start to translate JJF 1738-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1738-2019_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1738-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.