US$599.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1722-2018: Calibration Specification for Exercise Treadmills Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1722-2018 | English | 599 |
Add to Cart
|
5 days [Need to translate]
|
Calibration Specification for Exercise Treadmills
| Valid |
JJF 1722-2018
|
PDF similar to JJF 1722-2018
Basic data Standard ID | JJF 1722-2018 (JJF1722-2018) | Description (Translated English) | Calibration Specification for Exercise Treadmills | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A55 | Word Count Estimation | 26,234 | Date of Issue | 2018-12-25 | Date of Implementation | 2019-03-25 | Regulation (derived from) | State Administration of Markets, Announcement No.34 of 2018 | Issuing agency(ies) | State Administration for Market Regulation |
JJF 1722-2018: Calibration Specification for Exercise Treadmills---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Exercise Treadmills
National Metrology Technical Specification of the People's Republic
Motion Tablet Calibration Specifications
Published on.2018-12-25
2019-03-25 implementation
State Market Supervisory Administration released
Motion Tablet Calibration Specifications
Focal Point. National Medical Metrology Technical Committee
Drafting unit. Hangzhou Quality and Technology Supervision and Inspection Institute
China Institute of Metrology
China Testing Technology Research Institute
China Metrology University
This Code entrusts the National Medical Metrology Technical Committee to explain
Drafters of this specification.
Jiang Xueping (Hangzhou Quality and Technical Supervision and Inspection Institute)
Yang Lei (China Institute of Metrology)
Zhang Conghua (China Testing Technology Research Institute)
Hu Jiacheng (China Metrology University)
Zheng Ru (Hangzhou Quality and Technical Supervision and Inspection Institute)
Wang Xinxin (China Metrology University)
table of Contents
Introduction (II)
1 Scope (1)
2 References (1)
3 Terms and units of measurement (1)
4 Overview (1)
5 Measurement characteristics (1)
5.1 Calibration voltage (1)
5.2 Voltage Measurement (1)
5.3 Polarization resistance voltage (1)
5.4 amplitude frequency characteristics (2)
5.5 heart rate (2)
5.6 Recording speed (2)
5.7 Minimum sensitivity threshold (2)
5.8 Noise Level (2)
5.9 Common mode rejection ratio (2)
5.10 plate speed (2)
6 Calibration conditions (2)
6.1 Environmental conditions (2)
6.2 Measurement standards and other equipment (2)
7 Calibration items and calibration methods (3)
7.1 Appearance and normality check (3)
7.2 Calibration voltage (3)
7.3 Voltage Measurement (3)
7.4 Polarization resistance voltage (4)
7.5 amplitude frequency characteristics (4)
7.6 heart rate (5)
7.7 Recording speed (5)
7.8 Minimum sensitivity threshold (6)
7.9 Noise Level (6)
7.10 Common mode rejection ratio (6)
7.11 Speed error (7)
8 Calibration result expression (7)
9 re-study interval (8)
Appendix A Sports Tablet Calibration Original Record (Recommended) Format (9)
Appendix B Calibration Certificate Inner Page (Recommended) Format (12)
Appendix C Example of Measurement Uncertainty Evaluation (14)
Introduction
JJF 1071 "National Metrology Calibration Specification Writing Rules", JJF 1001 "General Measurement Terms and Definitions",
JJF 1059.1 "Measurement and Representation of Measurement Uncertainty" together constitutes the basic document supporting the development of this specification. Regulation
Fan refers to JJG543-2008 "electrocardiograph", JJG1041-2008 "digital electrocardiograph", JJG1042-
2008 Dynamic (Removable) Electrocardiograph, YY1139-2013 "Electrocardiographic Diagnostic Equipment".
This specification is the first release.
Motion Tablet Calibration Specifications
1 Scope
This specification applies to the calibration of ECG function parameters and motion speed parameters of the sports tablet.
2 reference files
This specification refers to the following documents.
JJG543-2008 ECG machine
JJG1041-2008 digital electrocardiograph
JJG1042-2008 dynamic (removable) electrocardiograph
YY1139-2013 ECG diagnostic equipment
For dated references, only dated versions apply to this specification; for undated references,
The latest version (including all amendments) applies to this specification.
3 terms and units of measure
3.1 sports tablet exercisetreadmil
It is a kind of heart that uses signal processing to effectively measure the ECG characteristic parameters generated by the motion plate test.
Electrical diagnostic equipment. By analyzing the exercise electrocardiogram, the corresponding relationship of various ECG parameters is determined to assist the medical staff.
The staff diagnosed coronary heart disease.
3.2 exercise plate test treadmilexercisetest
Also known as exercise load test, it is to increase the load of the heart through grading exercise, so that the oxygen consumption of the heart is increased.
Myocardial ischemia is induced when the load reaches a certain amount, and the diagnosis of coronary heart disease is assisted by the results of electrocardiogram examination.
4 Overview
The sports tablet is based on the motion ECG analysis system, which realizes the standard simultaneous acquisition of ECG signal 12-lead, mainly by
ECG signal acquisition, transmission, reception, analysis, tablet control and other systems.
The motion tablet is divided into wired and wireless according to the ECG signal transmission and reception methods.
5 Measurement characteristics
5.1 Calibration voltage
The maximum allowable error is ±5%.
5.2 Voltage measurement
The maximum allowable error is ±101
U1
Uin
÷% calculation (where U1 is the minimum value of the voltage measurement range, ie 0.1mV).
5.3 Polarization resistance voltage
After applying a DC polarization voltage of ±300 mV, the baseline should be free of significant offset and the amplitude variation should be within ±5%.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1722-2018_English be delivered?Answer: Upon your order, we will start to translate JJF 1722-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1722-2018_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1722-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|