JJF 1721-2018: Calibration Specification for Carbonization Depth Measuring Instruments and Calipers
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1721-2018English419 Add to Cart 4 days [Need to translate] Calibration Specification for Carbonization Depth Measuring Instruments and Calipers Valid JJF 1721-2018

PDF similar to JJF 1721-2018


Standard similar to JJF 1721-2018

JJF 1951   JJF 1561   JJF 1406   JJF 1960   JJF 1367   JJF 1719   

Basic data

Standard ID JJF 1721-2018 (JJF1721-2018)
Description (Translated English) Calibration Specification for Carbonization Depth Measuring Instruments and Calipers
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A52
Word Count Estimation 18,191
Date of Issue 2018-12-25
Date of Implementation 2019-03-25
Regulation (derived from) State Administration of Markets, Announcement No. 34 of 2018
Issuing agency(ies) State Administration for Market Regulation

JJF 1721-2018: Calibration Specification for Carbonization Depth Measuring Instruments and Calipers


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Carbonization depth gauge and gauge calibration specifications) National Metrology Technical Specification Carbonization depth gauge and gauge calibration specifications Published on.2018-12-25 2019-03-25 implementation State Market Supervisory Administration released Carbonization depth gauge and Measuring rule calibration specification Focal Point. National Geometric Quantity Engineering Measurement Technology Committee Main drafting unit. Guangxi Zhuang Autonomous Region Metrology and Inspection Institute Henan Institute of Metrology Participated in drafting unit. Xiamen Saibao Industrial Technology Research Institute Co., Ltd. Anhui Institute of Metrology This specification entrusts the National Geometric Quantity Engineering Parameter Measurement Technical Committee to explain The main drafters of this specification. Yang Mingzhu (Guangxi Zhuang Autonomous Region Metrology and Testing Institute) Huang Yuzhu (Henan Institute of Metrology) Jia Xiaojie (Henan Institute of Metrology) Participate in the drafters. Chang Hao (Xiamen Saibao Industrial Technology Research Institute Co., Ltd.) Ma Lin (Anhui Institute of Metrology) Li Shuangding (Guangxi Zhuang Autonomous Region Metrology and Testing Institute) Su Yixiong (Guangxi Zhuang Autonomous Region Metrology and Testing Institute)

table of Contents

Introduction (III) 1 Scope (1) 2 References (1) 3 terms (1) 4 Overview (1) 5 Measurement characteristics (3) 5.1 zero error (3) 5.2 Indication variability (3) 5.3 indication error (3) 5.4 proofreading block height (4) 6 Calibration conditions (4) 6.1 Environmental conditions (4) 6.2 Measurement standards and other equipment (4) 7 Calibration items and calibration methods (4) 7.1 Calibration Project (4) 7.2 Calibration method (4) 8 calibration result expression (5) 9 re-study interval (5) Appendix A Example of Calibration Uncertainty Evaluation of Indicator Error of Pointed Carbonation Depth Gauge (6) Appendix B Example of Calibration Uncertainty Evaluation for Numerical Display Carbonization Depth Gauge Indication Error (8) Appendix C Calibration Certificate Contents and Inner Page Format (10)

Introduction

This specification is based on JJF 1071-2010 "Rules for the preparation of national metrological calibration specifications", JJF 1001-2011 Measurement Terms and Definitions, JJF 1094-2002 "Measuring Instrument Characteristics" and JJF 1059.1-2012 Volume Uncertainty Assessment and Representation is based on and based on the basis. This specification is the first release. Carbonization depth gauge and gauge calibration specifications

1 Scope

This specification applies to the measurement of the depth of carbonization with a graduation value/resolution of 0.25 mm and an upper limit of the measurement range up to 8 mm. Instrument, and the degree of resolution/resolution is 0.01mm, 0.02mm, the measurement range is up to 70mm carbonization depth measurement Calibration of the ruler. Other types of carbonization depth gauges and gauges are also available for reference.

2 reference files

This specification refers to the following documents. JJG30 universal caliper JGJ/T 23 Rebound method for testing concrete compressive strength For dated references, only dated versions apply to this specification; undated quotations The latest version (including all amendments) applies to this specification.

3 terms

3.1 Carbonization depth carbonizationdepth The vertical distance between the carbonized and uncarbonized interface of the concrete to the concrete surface. 3.2 Rebound method Using a spring-driven weight hammer, the concrete surface is struck by the impact rod (the force-transmitting rod), and the weight is detected to be rebounded. The distance returned, with the rebound value (ratio of the bounce distance to the initial length of the spring) as an indicator related to the intensity, A method of determining the strength of concrete.

4 Overview

The carbonization depth measuring instrument and measuring ruler are used to measure the surface carbonization layer of the measured surface when the concrete strength is measured by the rebound method. Dedicated equipment for depth. It is widely used for the measurement of the depth of carbonized layers on concrete and other building materials. How it is read Divided into pointer, cursor and digital. Its outline structure is shown in Figure 1, Figure 2, Figure 3, and Figure 4.