JJF 1699-2018: Program of Pattern Evaluation of Mining Carbon Monoxide Monitors
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1699-2018English919 Add to Cart 7 days [Need to translate] Program of Pattern Evaluation of Mining Carbon Monoxide Monitors Valid JJF 1699-2018

PDF similar to JJF 1699-2018


Standard similar to JJF 1699-2018

JJF 1424   JJF 1441   JJF 1363   JJF 1695   JJF 1696   JJF 1694   

Basic data

Standard ID JJF 1699-2018 (JJF1699-2018)
Description (Translated English) Program of Pattern Evaluation of Mining Carbon Monoxide Monitors
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A61
Word Count Estimation 40,47
Date of Issue 2018-02-27
Date of Implementation 2018-05-27
Regulation (derived from) AQSIQ Announcement No. 26 of 2018
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine

JJF 1699-2018: Program of Pattern Evaluation of Mining Carbon Monoxide Monitors

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Mine carbon monoxide detection alarm type evaluation outline) National Metrology Technical Specification of the People's Republic Mine carbon monoxide detection alarm Type evaluation outline Published on.2018-02-27 2018-05-27 implementation The General Administration of Quality Supervision, Inspection and Quarantine issued Mine carbon monoxide detection alarm Type evaluation outline Focal Point. National Environmental Chemometrics Technical Committee Main drafting unit. National Mine Safety Metering Station Anbiao National Mine Product Safety Mark Center China Testing Technology Research Institute Participated in the drafting unit. China Coal Science and Technology Group Chongqing Research Institute Co., Ltd. National Safety Production Chongqing Mining Equipment Inspection and Inspection Center Chongqing Kean Electronics Co., Ltd. This Code entrusts the National Environmental Chemometrics Technical Committee to explain The main drafters of this specification. Zhang Anran (National Mine Safety Metering Station) Hu Jihong (Anbiao National Mine Product Safety Mark Center) Liu Qing (China Testing Technology Research Institute) Participate in the drafters. Zhu Zhengxian (China Coal Science and Technology Group Chongqing Research Institute Co., Ltd.) Fu Jiantao (National Mine Safety Metering Station) Fu Gang (National Safety Production Chongqing Mining Equipment Inspection and Inspection Center) Du Jianguo (Chongqing Kean Electronics Co., Ltd.)

table of Contents

Introduction (II) 1 Scope (1) 2 References (1) 3 Overview (1) 4 Legal management requirements (2) 4.1 Unit of measurement (2) 4.2 Signs and Logos (2) 5 Measurement requirements (2) 5.1 indication error (2) 5.2 Repeatability (2) 5.3 Response time (2) 5.4 drift (2) 6 General technical requirements (3) 6.1 Appearance and Structure (3) 6.2 Power check (3) 6.3 Functional requirements (3) 6.4 Power supply voltage adaptability (3) 6.5 Transmission error (3) 6.6 Insulation resistance (3) 6.7 Dielectric strength (3) 6.8 Environmental Adaptability (3) 6.9 Work Stability (4) 7 type evaluation items (4) 8 Provide the number of prototypes and how to use the prototype (5) 8.1 Provide the number and requirements of the prototype (5) 8.2 How to use the prototype (5) 9 Test methods and conditions of test items and data processing and qualification criteria (5) 9.1 Measurement requirements (5) 9.2 General technical requirements (9) 10 Measuring instruments and equipment used in the test items (14) 11 type evaluation record format (15) Appendix A Type evaluation record format for mine carbon monoxide detection alarm (16) Appendix B Technical Requirements for Simulation Circuits (35)

Introduction

This syllabus is based on JJF 1016-2014 "Guidelines for the preparation of type evaluation scales for measuring instruments", JJF 1015-2014 "General Specification for Type Evaluation of Measuring Instruments" and JJF 1001-2011 "General Terms and Definitions of Measurement". The technical indicators of this syllabus refer to JJG1093-2013 "Mineral Carbon Monoxide Detection Alarm", MT703- 2008 "Carrying Electrochemical Carbon Monoxide Detector for Coal Mines", AQ6205-2006 "Electrochemical One for Coal Mines" Carbon oxide sensor, etc. This syllabus is the first release. Mine carbon monoxide detection alarm type evaluation outline

1 Scope

This type of evaluation outline applies to the carbon monoxide of the electrochemical principle used under the classification of 46381500 mine. Type evaluation of the detection alarm (hereinafter referred to as the detection alarm).

2 reference files

This specification refers to the following documents. GB/T 2423.1-2008 Environmental testing for electric and electronic products - Part 2. Test methods Test A. Low temperature GB/T 2423.2-2008 Environmental testing for electric and electronic products - Part 2. Test methods Test B. high temperature GB/T 2423.4-2008 Environmental testing of electric and electronic products - Part 2. Test method test Db. Alternating heat and humidity (12h 12h cycle) Note. For dated references, only dated versions apply to this specification; any undated references The latest version of the document (including all amendments) applies to this specification.

3 Overview

The detection alarm is used to detect the concentration of carbon monoxide gas in the mine operating environment. When the concentration of carbon monoxide gas When the alarm setting value is exceeded, the sound and light alarm signals can be automatically generated. The detection alarm is mainly composed of a carbon monoxide electrochemical sensor, electronic components and a display part, and is electrochemically transmitted. The sensor converts the concentration of carbon monoxide gas in the environment into an electrical signal, which is then processed by electronic components and used as a concentration value. display. Depending on the mode of use, the detector alarm can be divided into portable (mine industry is known as alarm meter or measurement) And fixed type (known in the mining industry as a sensor). The stationary detection alarm also has a signal corresponding to the concentration Output function. According to the characteristics of the detection alarm, key components and materials should be clarified. The format is shown in Table 1. Table 1 Key Parts and Materials Table Serial number name main performance indicator remarks 1 shell non-metallic shell

2 electrochemical sensor

Response time. ≤30s Resolution. 1μmol/mol

3 battery for portable


Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1699-2018_English be delivered?

Answer: Upon your order, we will start to translate JJF 1699-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1699-2018_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1699-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.