US$899.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1673-2017: Calibration Specification for Voltage Dips, Short Interruptions and Voltage Variations Test Generators Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1673-2017 | English | 899 |
Add to Cart
|
6 days [Need to translate]
|
Calibration Specification for Voltage Dips, Short Interruptions and Voltage Variations Test Generators
| Valid |
JJF 1673-2017
|
PDF similar to JJF 1673-2017
Basic data Standard ID | JJF 1673-2017 (JJF1673-2017) | Description (Translated English) | Calibration Specification for Voltage Dips, Short Interruptions and Voltage Variations Test Generators | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A56 | Classification of International Standard | 17.220 | Word Count Estimation | 39,332 | Date of Issue | 2017-11-20 | Date of Implementation | 2018-02-20 | Quoted Standard | GB/T 17626.11-2008; GB/T 17626.29-2006; IEC 61000-4-11-2004; IEC 61000-4-29-2000 | Regulation (derived from) | AQSIQ Notice 2017 No. 103 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to GB/T 17626. 11-2008 "Electromagnetic compatibility test and measurement technology voltage dips, short-term interruption and voltage change immunity test", GB/T 17626.29-2006 "Electromagnetic compatibility test and measurement technology Immunity test for voltage dips, short-term interruptions and voltage variations of DC power input ports, IEC 61000-4-11:2004 "Electromagnetic compatibility test and measurement techniques Voltage sag, short interruptions and voltage change immunity tests And IEC 61000-4-29:2000 "Electromagnetic compatibility test and measurement techniques Voltage dips, short interruptions and interruptions required in voltage sags, short interruptions and voltage variations of input terminals for direct current power sources" |
JJF 1673-2017: Calibration Specification for Voltage Dips, Short Interruptions and Voltage Variations Test Generators ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Voltage Dips, Short Interruptions and Voltage Variations Test Generators
People's Republic of China National Metrology Technical Specifications
Voltage dips, short interruptions and voltage change tests
Generator Calibration Specifications
Published on.2017-11-20
2018-02-20 Implementation
The State Administration of Quality Supervision, Inspection and Quarantine issued
Voltage dips, short interruptions and voltage changes
Calibration Test Generator Calibration Specifications
Undertaking unit. National Radio Measurement Technical Committee
Drafted by. Guangdong Provincial Academy of Metrology
China Institute of Metrology
Guangdong Metrology Institute, Dongguan Metrology Institute
Participated in drafting. Liaoning Academy of Metrology
Shanghai Institute of Metrology and Measurement Technology
This specification entrusts the National Radiometric Technical Committee to explain
The main drafters of this specification.
Wengang Liu (Guangdong Provincial Institute of Metrology)
Huang Pan (China Institute of Metrology)
Nan Zhang (Dongguan Metrology Institute, Guangdong Metrology Institute)
Participating drafters.
Chen Yisheng (Guangdong Provincial Institute of Metrology)
Hao Song (Liaoning Provincial Institute of Metrology)
Shi Bin (Shanghai Measurement and Measurement Technology Research Institute)
Chang Zhifang (Guangdong Provincial Institute of Metrology)
table of Contents
Introduction (III)
1 Scope (1)
2 References (1)
3 Terms and units of measure (1)
3.1 Voltage Dips (1)
3.2 Short interruptions (1)
3.3 Voltage Changes (2)
4 Overview (2)
5 Metrological characteristics (3)
5.1 Single-phase voltage drop generator (3)
5.2 DC Voltage Drop Generator (4)
6 Calibration Conditions (5)
6.1 Environmental Conditions (5)
6.2 Measurement Standards and Other Equipment (5)
7 Calibration Items and Calibration Methods (6)
7.1 Calibration Items (6)
7.2 Appearance and normality check (7)
7.3 Single-phase voltage drop generator (7)
7.4 DC Voltage Drop Generator (13)
8 Calibration Results (15)
9 Re-school interval (16)
Appendix A Original record page format (17)
Appendix B Internal Format of Calibration Certificate (22)
Appendix C Example of Evaluation of Measurement Uncertainty for Calibration Results (29)
Appendix D Voltage Dips, Short Interruptions, and Voltage Variation Test Generators for Three-Phase Power Systems (34)
Introduction
This specification is based on JJF 1071-2010 "Rules for the preparation of national metrological calibration specifications", JJF 1059.1-2012 "Testing
"Uncertainty Evaluation and Expression" in the preparation of the requirements.
This specification mainly refers to GB/T 17626.11-2008 "Electromagnetic compatibility test and measurement technology voltage sag,
Short Interruption and Voltage Variation Immunity Test, GB/T 17626.29-2006 Electromagnetic Compatibility Test and Measurement
Technical dc power supply input port voltage dips, short interruptions and voltage change immunity tests, IEC 61000-4-11.
2004 "Electromagnetic Compatibility Test and Measurement Technology Voltage Dips, Short Interruptions, and Voltage Variation Immunity Tests" and
IEC 61000-4-29.2000 "Electromagnetic compatibility test and measurement technology DC power supply input port voltage sags, short
The relevant clauses in the Interruption and Voltage Variation Immunity Test were prepared.
This specification is the first release.
Voltage dips, short interruptions and voltage change tests
Generator Calibration Specifications
1 Scope
This specification applies to meet the GB/T 17626.11-2008 "electromagnetic compatibility test and measurement technology voltage temporarily
Immunity test for drop, short interruption and voltage change", GB/T 17626.29-2006 Electromagnetic Compatibility Test and
Measurement Technology Immunity Test for Voltage Dips, Short Interruptions, and Voltage Changes at Input Ports of DC Power Supplies,”
IEC 61000-4-11.2004 "Electromagnetic compatibility test and measurement techniques - Voltage sag, short interruptions and voltage variations
Immunity Test" and IEC 61000-4-29.2000 "Electromagnetic Compatibility Test and Measurement Technology DC Power Supply Inputs
Voltage sags, short interruptions, and voltages as required by port voltage dips, short interruptions, and voltage variation immunity tests
Change Test Generator [includes single-phase voltage dips, short interruptions, and voltage change test generators (also known as single-phase voltages)
Drop generator) and DC voltage sags, short interruptions and voltage change test generators (also known as DC voltage drops
Biometric)] calibration.
2 references
This specification refers to the following documents.
GB/T 17626.11-2008 Electromagnetic compatibility test and measurement techniques Voltage sags, short interruptions and voltages
Changed immunity test
GB/T 17626.29-2006 Electromagnetic Compatibility Test and Measurement Technology DC Power Input Port Voltage Temporary
Immunity test for drop, short interruption and voltage change
IEC 61000-4-11.2004 Electromagnetic compatibility Testing and measurement techniques Voltage sag, short interruptions and voltages
Changed immunity test (Electromagneticcompatibility-Testingandmeasurementtechniques-
Voltagedips,shortinterruptionsandvoltagevariationsimmunitytests)
IEC 61000-4-29.2000 EMC test and measurement techniques DC power input port voltage temporarily
Low-frequency, short-term interruption and voltage change immunity test (Electromagneticcompatibility-Testingand
measurementtechniques-Voltagedips, shortinterruptionsandvoltagevariationsond.
C.inputpowerportimmunitytests)
For dated references, only dated editions apply to this specification; all undated references
The latest version (including all amendments) applies to this specification.
3 Terms and units of measure
The following terms and definitions apply to this specification.
3.1 Voltage dips voltagedips
The voltage at one point of the electrical supply system suddenly drops to the specified voltage and then goes through a brief interval
Return to normal value.
3.2 Short Interruption of Short Interruption
The voltage of all the phases at a certain point of the power supply system abruptly decreases below the specified interruption voltage, and then goes through a period of time
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1673-2017_English be delivered?Answer: Upon your order, we will start to translate JJF 1673-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1673-2017_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1673-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|