US$459.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1650-2017: Calibration Specification for Field Parameters of Ultrasound Flaw Detector Transducers Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1650-2017 | English | 459 |
Add to Cart
|
4 days [Need to translate]
|
Calibration Specification for Field Parameters of Ultrasound Flaw Detector Transducers
| Valid |
JJF 1650-2017
|
PDF similar to JJF 1650-2017
Basic data Standard ID | JJF 1650-2017 (JJF1650-2017) | Description (Translated English) | Calibration Specification for Field Parameters of Ultrasound Flaw Detector Transducers | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A59 | Classification of International Standard | 17.140 | Word Count Estimation | 20,211 | Date of Issue | 2017-11-20 | Date of Implementation | 2018-02-20 | Quoted Standard | JJF 1001; JJF 1034; GB 3102.7; GB/T 16540-1996; GB/T 18694-2002; ASTM E 1065-08 | Regulation (derived from) | AQSIQ Notice 2017 No. 103 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard specifies the measurement characteristics, calibration conditions and calibration methods for the sound field of ultrasonic transducers (also called ��ultrasonic probes��) used for ultrasonic non-destructive testing. This standard applies to planar ultrasonic transducers and focused ultrasonic transducers with frequencies in the range of (0.5 to 15 MHz). The calibration of other ultrasonic transducers and their array sound field characteristics can also be referred to. |
JJF 1650-2017: Calibration Specification for Field Parameters of Ultrasound Flaw Detector Transducers ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Ultrasonic flaw detector transducer sound field characteristics calibration specification)
People's Republic of China National Metrology Technical Specifications
Ultrasonic flaw detector transducer sound field characteristics calibration specification
Published on.2017-11-20
2018-02-20 Implementation
The State Administration of Quality Supervision, Inspection and Quarantine issued
Ultrasonic flaw detector transducer sound
Field characteristics calibration specifications
Integral Unit. National Acoustic Measurement Technical Committee
Drafted by. China Academy of Metrology
Beijing Institute of Technology
Jilin Provincial Institute of Metrology
This specification entrusts the National Acoustic Measurement Technical Committee to explain
The main drafters of this specification.
Yang Ping (China Institute of Metrology)
Xu Chunguang (Beijing Institute of Technology)
Wenping Bin (China Academy of Metrology)
Xiao Dingguo (Beijing Institute of Technology)
Zhu Yan (China Institute of Metrology)
Fang Facheng (Jilin Provincial Institute of Metrology)
table of Contents
Introduction (II)
1 Scope (1)
2 References (1)
3 Terms and units of measure (1)
3.1 Sound beam diameter (1)
3.2 Sound beam spread angle (1)
3.3 depth of field (1)
4 Overview (2)
5 Metrological characteristics (2)
5.1 Near field length/focal length (2)
5.2 Sound beam diameter (2)
5.3 Beam Spread Angle (2)
5.4 depth of field (2)
6 Calibration Conditions (2)
6.1 Environmental Conditions (2)
6.2 Measurement Standards and Other Equipment (2)
7 Calibration Items and Calibration Methods (3)
7.1 Calibration Items (3)
7.2 Calibration Methods (3)
8 Expression of Calibration Results (5)
8.1 Calibration Data Processing (5)
8.2 Calibration Certificate (5)
8.3 Evaluation of Uncertainty of Calibration Results (5)
9 Re-school interval (6)
Appendix A Content of Calibration Certificate (7)
Appendix B Evaluation Examples of Measurement Uncertainty (10)
Appendix C Table of Sound Speed vs. Temperature of Deionized Water (13)
Appendix D Selection of Hydrophones (14)
Introduction
This specification is based on the rules and formats given in JJF 1071-2010 "Rules for the preparation of national metrological calibration specifications".
Line preparation.
This specification refers to GB/T 18694-2002 "Non-destructive testing of ultrasonic testing probes and its characterization of the sound field",
ASTME1065-08 Standard Guide for Evaluating Characteristics of Ultrasonic Scanners (Standard Guidefor
The measuring method described in EvaluatingCharacteristicsofUltrasonicSearchUnits), the main characteristics of the sound field
Refer to ASTM E1065-08, including near field length/focal length, beam diameter, beam spread angle, field depth, etc.
parameter.
This specification is the first release.
Ultrasonic flaw detector transducer sound field characteristics calibration specification
1 Scope
This specification specifies the sound field of an ultrasonic transducer (also called “ultrasonic probe”) used for ultrasonic non-destructive testing.
Metering characteristics, calibration conditions, and calibration methods. This specification applies to planes with frequencies in the range of (0.5 to 15) MHz
Ultrasound transducers and focused ultrasound transducers. Other ultrasonic transducers and their arrays can be referenced for calibration of the sound field characteristics.
use.
2 references
This specification refers to the following documents.
JJF 1001 Universal Measurement Terms and Definitions
JJF 1034 Acoustic Measurement Terms Terms and Definitions
GB 3102.7 Acoustic quantities and units
GB/T 16540-1996 Ultrasonic field characteristics and measurement water in the frequency range from (0.5 to 15) MHz
Hearing method
GB/T 18694-2002 Non-destructive testing ultrasonic inspection probe and its sound field characterization
ASTME1065-08 Standard Guide for Evaluating Characteristics of Ultrasonic Scanners (Standard Guide for Eval-
uatingCharacteristicsofUltrasonicSearchUnits)
For dated references, only dated editions apply to this specification; all undated references
The latest version (including all amendments) applies to this specification.
3 Terms and units of measure
This specification uses the related terms and definitions in JJF 1001 and JJF 1034.
This specification uses the amount and unit specified in GB 3102.7.
3.1 Sound beam diameter
In the section of the sound field parallel to the surface of the ultrasonic transducer, the choice is several decibels below the maximum (generally 3 dB)
Or 6 dB) of a closed curve consisting of the same amplitude points and fitting it to form a circle, the diameter of the circle is the
The beam diameter in millimeters (mm).
3.2 beam spread angle beamspread
Taking the acoustic axis as a reference line, in a certain section of the acoustic axis direction, the acoustic pressure at the acoustic axis is selected to be lower than that at the acoustic axis.
The points of decibel (usually 3dB or 6dB) are fitted into two straight lines, and the angle between the two straight lines is the segment.
The sound field spread angle in degrees, in degrees (°).
3.3 depth of field depthoffield
In acoustic pressure field distribution on the acoustic axis, the maximum amplitude sound pressure drops 6 dB before and after the maximum amplitude (focal point)
The distance between two locations is the field depth of the ultrasonic transducer in millimeters (mm).
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1650-2017_English be delivered?Answer: Upon your order, we will start to translate JJF 1650-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1650-2017_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1650-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|