JJF 1580-2016: Calibration Specification for Artificial Mouths
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1580-2016English879 Add to Cart 5 days [Need to translate] Calibration Specification for Artificial Mouths Valid JJF 1580-2016

PDF similar to JJF 1580-2016


Standard similar to JJF 1580-2016

GB/T 3222.2   GB/T 3222.1   JJG 188   JJF 1581   JJF 1588   JJF 1579   

Basic data

Standard ID JJF 1580-2016 (JJF1580-2016)
Description (Translated English) Calibration Specification for Artificial Mouths
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A59
Word Count Estimation 38,311
Date of Issue 2016-11-25
Date of Implementation 2017-02-25
Regulation (derived from) State Administration of Quality Supervision, Inspection and Quarantine Notice No.116 of 2016
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine

JJF 1580-2016: Calibration Specification for Artificial Mouths

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Artificial Mouths National Metrological Technical Code of the People's Republic of China Simulation mouth calibration specification 2016-11-25 release 2017-02-25 Implementation State Administration of Quality Supervision, Inspection and Quarantine issued Simulation mouth calibration specification CalibrationSp Coordinate unit. National Acoustics Metrology Technical Committee The main drafting unit. Shenzhen Institute of measurement quality inspection Hengyang Hengyi Electric Co., Ltd. Hangzhou Aihua Instrument Co., Ltd. Participated in the drafting unit. China Institute of Metrology Shanghai Si Baiji Instrument System Co., Ltd This specification entrusts the National Acoustics Metrology Technical Committee to explain The main drafters of this specification. Zhang Guoqing (Shenzhen Institute of Measurement and Quality Inspection) Liu Xiangheng (Hengyang Hengyi Electric Co., Ltd.) Zhang Ning (Hangzhou Aihua Instrument Co., Ltd.) Participate in the drafters. Niu Feng (China Institute of Metrology) Dai Bin (Shanghai Si Baiji Instrument System Co., Ltd.) Zhang Ruige (Shenzhen Institute of Measurement and Quality Inspection) Zou Shipeng (Shenzhen Institute of Measurement and Quality Inspection)

table of Contents

Introduction (Ⅲ) 1 Scope (1) 2 References (1) 3 terms and units of measurement (1) 3.1 lip ring (1) 3.2 lip plane (2) 3.3 Simulation mouth (2) 3.4 Reference axis (2) 3.5 mouth reference point (MRP) (2) 3.6 sound field sound pressure distribution (2) 3.7 reference sound barrier (2) 3.8 sound barrier diffraction (2) 3.9 Simulation Speech (2) 3.10 electric simulation of spoken language (2) 3.11 sound simulation spoken tone (2) 4 Overview (3) 5 Metrological characteristics (3) 5.1 Near-field sound pressure distribution on the reference axis (3) 5.2 Reference axis external field sound pressure distribution (4) 5.3 Far-range sound pressure distribution on the reference axis (4) 5.4 Sound barrier diffraction (5) 5.5 Maximum sound pressure level that can be issued Lp, MAX (5) 5.6 Total distortion of sound signal (5) 5.7 Sound signal amplitude linearity (5) 6 Calibration conditions (6) 6.1 Environmental conditions (6) 6.2 Measurement standards and other equipment (6) 7 Calibration items and calibration methods (7) 7.1 Calibration items (7) 7.2 Calibration method (8) 8 Calibration results (15) 8.1 Calibration data processing (15) 8.2 Calibration Certificate (15) 8.3 Uncertainty of measurement of calibration results (16) 9 re-school time interval (16) Appendix A Contents of the Calibration Certificate (17) Appendix B Examples of Evaluation of Uncertainty (24) Appendix C simulation mouth near-field and far-field sound pressure measurement point selection and positioning (28) Appendix D pseudo-random noise signal measurement of the total distortion of the simulated mouth (30)

Introduction

This specification is based on the requirements and format of JJF 1071-2010 "National Metrological Calibration Rules". Technical aspects mainly refer to the international recommendations of the International Telecommunication Union ITU-TP.51..1996 "Simulation of the mouth" (Arti- ficialMouth) and JJF 1339-2012 "electro-acoustic tester calibration specifications". The calibration items for this specification are based on ITU-TP.51..1996. The total distortion of the sound signal Refer to the technical requirements of JJF 1339-2012 in 5.10. Simulation port for electroacoustic and telephone electroacoustic testing Compressed frequency response characteristics of the calibration can refer to JJG869-2002 "telephone electro-acoustic tester." This specification is based on JJF 1059.1-2012 "Measurement Uncertainty Assessment and Representation" gives the near-field sound on the reference axis An example of the evaluation of the uncertainty of the measurement of the difference in sound pressure spectrum of pressure distribution. This specification is the first release. Simulation mouth calibration specification

1 Scope

This specification applies to the calibration of electro-acoustic characteristics of analog ports in accordance with ITU-TP.51..1996 "Simulation mouth" requirements. Other simulation mouth calibration can refer to this specification.

2 reference file

This specification refers to the following documents. JJG176-2005 sound calibrator JJG869-2002 telephone electroacoustic tester Standard Terminology and Definitions for JJF 1001-2011 Terminology and definitions of acoustical metrology nouns JJF 1034-2005 Standard Specification for Acoustic Characteristics of Anechoic and Semi - anechoic Rooms JJF 1147-2006 Code for calibration of audio power amplifiers JJF 1200-2008 JJF 1288-2011 multi - channel acoustic analyzer calibration specification Standard for Calibration of Electroacoustic Testers JJF 1339-2012 GB 3102.7 The amount and unit of acoustics Terminology of acoustics nouns GB/T 3947-1996 ITU-TO.131 Quantitative Damping Test Equipment Using Pseudo-Random Noise Test Signals (QuantizingDistor- tionMeasuringEquipmentUsingaPseudo-randomNoiseTestSignal) ITU-TP.50..1996 Simulation of spoken speech (ArtificialVoices) ITU-TP.51..1996 Simulation mouth (ArtificialMouth) For dated references, only the dated edition applies to this specification; references that are not dated , The latest version (including all modifications) applies to this specification.

3 terms and units of measurement

JJF 1001-2011, GB/T 3947-1996, JJF 1034-2005 and ITU-TP.51..1996 Definitions and the following terms and definitions apply to this specification. This specification uses the amount and unit specified in GB 3102.7. 3.1 lip ring lipring A solid ring that simulates the effect of the lips. Note. 1 made of non-magnetic material, diameter 25mm, thickness less than 2mm. 2 can be firmly mounted on the simulation mouth. 3 lip ring defines the mouth reference axis and mouth reference point.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1580-2016_English be delivered?

Answer: Upon your order, we will start to translate JJF 1580-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1580-2016_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1580-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.