JJF 1505-2015: Calibration Specification for Acoustic Emission Instrumentation
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1505-2015English439 Add to Cart 3 days [Need to translate] Calibration Specification for Acoustic Emission Instrumentation Valid JJF 1505-2015

PDF similar to JJF 1505-2015


Standard similar to JJF 1505-2015

GB/T 3222.2   GB/T 3222.1   JJG 188   JJF 2012   JJF 1506   JJF 1504   

Basic data

Standard ID JJF 1505-2015 (JJF1505-2015)
Description (Translated English) Calibration Specification for Acoustic Emission Instrumentation
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A59
Classification of International Standard 17.140
Word Count Estimation 18,180
Date of Issue 2015-01-30
Date of Implementation 2015-04-30
Quoted Standard JJF 1001; JJF 1034; GB 3102.7-1993; GB/T 12604.4-2005; JB/T 8283-1999; ASTM E0750-10
Adopted Standard JB/T 8283-1999, NEQ; ASTM E0750-10, NEQ
Regulation (derived from) The State Administration of Quality Supervision, Inspection and Quarantine Announcement 2015 No. 19
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This Standard applies to the calibration of acoustic emission detector host, without sensor and preamplifier section.

JJF 1505-2015: Calibration Specification for Acoustic Emission Instrumentation

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Acoustic Emission Instrumentation People's Republic of China National Metrology Technical Specifications Acoustic emission detector calibration specification Issued on. 2015-01-30 2015-04-30 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Acoustic emission detector calibration specification Focal point. the National Committee of the acoustic measurement technology The main drafting units. China Institute of Metrology Hubei Provincial Institute of Metrology Participated in the drafting unit. Fujian Institute of Metrology Jiangsu Province Institute of Metrology Suzhou CEPREI Calibration Technology Services Ltd. Qingdao National Marine equipment testing center This specification metering commissioned National Technical Committee is responsible for interpreting acoustics The main drafters of this specification. He Longbiao (China Institute of Metrology) Niu Feng (China Institute of Metrology) Yao Qiuping (Hubei Institute of Metrology) Drafters participate. Lie (Fujian Institute of Metrology) Rong Xia Xun (Jiangsu Province Institute of Metrology) Lvlin Hua (Suzhou CEPREI Calibration Technology Services Ltd.) Lun Zhou Bin (Qingdao National Marine equipment testing center)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2. References (1) 3 Terms and Definitions (1) 3.1 Acoustic Emission (1) 3.2 acoustic emission signal amplitude (1) 3.3 Threshold (1) 3.4 impact (1) 3.5 Rise Time (1) Duration 3.6 (1) 3.7 Ring Count (2) Crosstalk 3.8 (2) 3.9 Noise (2) 4 Overview (2) 5 Metrological characteristics (2) 5.1 Noise (2) 5.2 Frequency Range (2) 5.3 Dynamic Range (2) Between 5.4 channel crosstalk (2) 5.5 waveform parameters (2) 6 calibration conditions (3) Environmental conditions 6.1 (3) 6.2 standards and other measuring equipment (3) 7 calibration items and calibration methods (3) 7.1 calibration items (3) 7.2 Calibration method (4) 8 calibration results expression (6) 8.1 Calibration Data Processing (6) 8.2 calibration certificate (7) 8.3 calibration measurement uncertainty (7) 9 Recalibration interval (7) Appendix A Recommended acoustic emission detector calibration certificate-page format (8) Appendix B acoustic emission detector calibration Uncertainty Evaluation for instance (10)

Introduction

This specification based JJF 1071-2010 "National Calibration Specifications writing rules" establishment. Making reference to this specification JB/T 8283-1999 "acoustic emission testing equipment performance testing methods" and ASTM E0750-10 "acoustic emission instrument characterization methods" (PracticeforcharacterizingAcousticEmissionIn- strumentation) acoustic emission detector part of the performance parameters and test methods. This specification is the first release. Acoustic emission detector calibration specification

1 Scope

This standard applies to the calibration of acoustic emission detector host, without sensor and preamplifier section. 2. References This specification references the following documents. JJF 1001 common measurement terms and definitions JJF 1034 acoustic measurement terminology and definitions GB 3102.7-1993 Quantities and units of acoustics GB/T 12604.4-2005 Terminology for nondestructive testing - Acoustic emission testing JB/T 8283-1999 acoustic emission detector performance test method ASTME0750-10 acoustic emission instrument characterization methods (PracticeforcharacterizingAcoustic EmissionInstrumentation) For dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 Terms and Definitions

This specification uses quantities and units specified in GB 3102.7-1993. JJF 1001 and JJF 1034 and as defined in the following terms and definitions apply to this specification. 3.1 Acoustic emission acousticemission Rapid release of energy within the material phenomenon generated by transient elastic waves. [GB/T 12604.4-2005, Definition 2.1] 3.2 acoustic emission signal amplitude acousticemissionsignalamplitude The maximum peak voltage amplitude of the waveform acoustic emission signals obtained. Note. Unit V, usually expressed in dB, the reference value 1μV. 3.3 Threshold thresholdvalue A predetermined voltage value, the acoustic emission signal amplitude exceeds the voltage value can be detected, usually in dB Shown, the reference value 1μV. NOTE. The threshold is generally also called threshold. 3.4 strike hit Exceeds the threshold and cause any signal acoustic emission detector channel data collection. 3.5 rise time risetime AE signal exceeds the first threshold value to the maximum amplitude of the elapsed time interval. 3.6 Duration durationtime AE signal exceeds the threshold for the first time to descend to the final time threshold interval.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1505-2015_English be delivered?

Answer: Upon your order, we will start to translate JJF 1505-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1505-2015_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1505-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.