JJF 1502-2015 English PDF

US$419.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1502-2015: Calibration Specification for Reference Ballasts
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1502-2015English419 Add to Cart 3 days [Need to translate] Calibration Specification for Reference Ballasts Valid JJF 1502-2015

PDF similar to JJF 1502-2015


Standard similar to JJF 1502-2015

JJF 1234   JJF 1576   JJG 376   JJF 2001   JJF 2018   JJF 2000   

Basic data

Standard ID JJF 1502-2015 (JJF1502-2015)
Description (Translated English) Calibration Specification for Reference Ballasts
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A55
Classification of International Standard 17.22
Word Count Estimation 17,184
Date of Issue 2015-01-30
Date of Implementation 2015-04-30
Quoted Standard GB/T 10682-2010; GB/T 14044-2008; GB/T 15042-2008; GB/T 15144-2009; GB/T 17262-2011; GB/T 19510.13-2007
Regulation (derived from) The State Administration of Quality Supervision, Inspection and Quarantine Announcement 2015 No. 19
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This Standard applies to the nominal frequency is 50 Hz, 60 Hz and 20 kHz ~ 50 kHz calibration reference ballast.

JJF 1502-2015: Calibration Specification for Reference Ballasts

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Reference Ballasts People's Republic of China National Metrology Technical Specifications Reference ballast calibration specifications Issued on. 2015-01-30 2015-04-30 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Reference ballast calibration specifications Focal point. the National Technical Committee on Electromagnetic measurement Main drafting unit. Zhejiang Institute of Metrology Participated in the drafting. Hangzhou distance Photoelectric Information Co., Ltd. This specification commissioned the National Technical Committee Electromagnetic responsible for the interpretation of measurement The main drafters of this specification. Chen Zhiming (Zhejiang Institute of Metrology) Zheng Mengxia (Zhejiang Institute of Metrology) Drafters participate. Pan Jiangen (Hangzhou distance Optoelectronic Information Co., Ltd.) Liu Qin (Zhejiang Institute of Metrology)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2. References (1) 3 terminology and units of measurement (1) 3.1 calibration current (1) Voltage and current ratio 3.2 (1) 4 Overview (1) 5 Metrological characteristics (1) 5.1 voltage and current ratio (impedance) (1) 5.2 Power Factor (2) Calibration Condition 6 (2) 6.1 environmental conditions (2) 6.2 standards and other measuring equipment (2) 7 calibration items and calibration methods (3) 7.1 calibration items (3) 7.2 Calibration method (3) 8 calibration results expression (4) 9 Recalibration interval (5) Appendix A Measurement Uncertainty Example (6) Appendix B Calibration original record format (9) Appendix C calibration certificate page format (10)

Introduction

This specification based JJF 1071-2010 "National Calibration Specifications writing rules", JJF 1001-2011 "Tong Metering Terms and definitions "and JJF 1059.1-2012" Evaluation and Expression of Uncertainty in Measurement "establishment. The specification for the first time to develop. Reference ballast calibration specifications

1 Scope

This specification applies to the rated frequency of 50Hz, 60Hz and 20kHz ~ 50kHz reference ballast calibration. 2. References This specification refers to the following documents. GB/T 10682-2010 double capped fluorescent lamps - Performance requirements GB/T 14044-2008 requirements for ballasts for tubular fluorescent lamps Performance GB/T 15042-2008 light discharge lamps (excluding tubular fluorescent lamps) - Performance requirements Ballasts GB/T 15144-2009 tubular fluorescent lamps with electronic ballasts performance requirements GB/T 17262-2011 Single-capped fluorescent lamps - Performance requirements Part 13 control unit GB/T 19510.13-2007 lamp. discharge lamps (excluding fluorescent lamps) with a straight Specific requirements for the exchange of electronic ballasts or For dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 terminology and units of measurement

This specification uses the following terms and units of measurement. 3.1 Calibration current calibrationcurrent Calibration and adjustment of the reference ballast is based on the current value; unit. A. Voltage and current ratio 3.2 voltagecurrentratio Current terminal voltage divided by the reference ballast, that the reference ballast impedance; Unit. Ω.

4 Overview

Reference ballast is connected between the power source and the light source, to provide a baseline reference for measuring electrical characteristics of the light source parameters point. Frequency of 50Hz or 60Hz reference ballast is a special design of inductive ballast, by one or Several self-inductance coil, mounted or fitted with an auxiliary resistor; reference frequency of the town of 20kHz ~ 50kHz stream Device is a specially designed ballast resistor, by one or more of a resistor, can be equipped with an appropriate inductance or capacitance. Reference ballast is usually installed in the seal with mechanical, electrical, and magnetic protection housing. Reference ballast according to the assignment into a single value of the reference ballast, multi-valued reference ballast; subjects were divided into fluorescent lamps by Job Reference ballast and high-intensity discharge lamp ballasts reference; according to the working frequency divided reference frequency ballasts, high frequency group Associate ballast, wherein the reference frequency inductive ballasts, high frequency ballast reference was resistive.

5 Metrological characteristics

5.1 voltage and current ratio (impedance) 5.1.1 The ballast voltage reference current ratio (impedance) should be GB/T 10682 or GB/T 17262 Base Light

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1502-2015_English be delivered?

Answer: Upon your order, we will start to translate JJF 1502-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1502-2015_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1502-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?