US$669.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1494-2014: Calibration Specification for Network Cable Analyzers Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1494-2014 | English | 669 |
Add to Cart
|
5 days [Need to translate]
|
Calibration Specification for Network Cable Analyzers
| Valid |
JJF 1494-2014
|
PDF similar to JJF 1494-2014
Basic data Standard ID | JJF 1494-2014 (JJF1494-2014) | Description (Translated English) | Calibration Specification for Network Cable Analyzers | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A56 | Classification of International Standard | 17.220 | Word Count Estimation | 29,282 | Date of Issue | 11/17/2014 | Date of Implementation | 2/17/2015 | Quoted Standard | TIA-1152 | Regulation (derived from) | The State Administration of Quality Supervision, Inspection and Quarantine Notice 2014 No. 125 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This Standard applies to testing 5, 5E, 6 etc. twisted-pair cable network analyzer calibration. Testing over 6 class 7 class twisted-pair network cable analyzer can use reference. |
JJF 1494-2014: Calibration Specification for Network Cable Analyzers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Network Cable Analyzers
People's Republic of China National Metrology Technical Specifications
Cable network analyzer
Calibration Specification
Issued on. 2014-11-17
2015-02-17 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Cable network analyzer
Calibration Specification
Focal point. the National Radio Technical Commission metering
The main drafting units. the Ministry of Industry and Information Technology Institute of Electronics V
Shanghai Measurement and Testing Technology Research Institute
Participated in the drafting. the Ministry of Industry and Information Technology and Telecommunication Metrology Center
Shanghai Electric Cable Research Institute
This specification commissioned the National Radio Technical Commission responsible for the interpretation of measurement
The main drafters of this specification.
Lisheng Hai (Ministry of Industry and Information Technology Institute of Electronics V)
Wang Yong (Ministry of Industry and Information Technology Institute of Electronics V)
Zhan Zhiqiang (Shanghai Institute of Measurement and Testing)
Drafters participate.
Yangqiao new (Ministry of Industry and Information Technology Institute of Electronics V)
Xu Wei (Ministry of Industry and Information Technology Telecommunication Metrology Center)
Tu Jian Kun (Shanghai Electric Cable Research Institute)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 terminology and units of measurement (1)
The propagation delay of 3.1 (1)
3.2 Near-end crosstalk (1)
3.3 equivalent far-end crosstalk (1)
4 Overview (1)
5 Metrological characteristics (1)
5.1 DC loop resistance (1)
Propagation delay of 5.2 (2)
5.3 Insertion Loss (2)
5.4 Near-end crosstalk (2)
5.5 equivalent far-end crosstalk (2)
Return Loss 5.6 (2)
Length 5.7 (2)
Calibration Condition 6 (2)
6.1 environmental conditions (2)
6.2 standards and other measuring equipment (2)
7 calibration items and calibration methods (4)
7.1 appearance and working properly check (4)
7.2 DC loop resistance (4)
Propagation delay of 7.3 (5)
Insertion Loss 7.4 (5)
7.5 Near-end crosstalk (5)
7.6 equivalent far-end crosstalk (6)
7.7 Length (8)
7.8 Return Loss (8)
Expression 8 calibration results (9)
9 Recalibration interval (9)
Appendix A Calibration Record Form (10)
Appendix B DC loop resistance calibration Measurement Uncertainty (18)
Appendix C return loss aid and RJ45 calibration member (21)
Appendix D impedance converter (22)
Appendix E ELFEXT simulator (23)
Introduction
Prepared on the basis of the calibration standard is JJF 1071-2010 "national measurement calibration specifications writing rules" and
JJF 1059.1-2012 "Evaluation and Expression of Uncertainty in Measurement."
This calibration technique based on the following main specifications of international standards.
IEC 61156-1 "digital telecommunication use of quad-core symmetric multi-cable, Part 1. Generic specification" (Mul-
ticoreandsymmetricalpair/quadcablesfordigitalcommunications-Part 1. Generic
specification);
IEC 61935-1 "balanced and coaxial information technology cabling test specification, Part I. The ISO /IEC 11801
Wiring and balance "(Specificationforthetestingofbalancedand the relevant provisions of the standard installation
coaxialinformationtechnologycabling-Part 1. Instaledbalancedcablingasspecifiedin
ISO /IEC 11801andrelatedstandards);
ANSI/T IA/EIA-568 "Commercial Building Telecommunications Cabling Standard. balanced twisted-pair cabling and telecommunications hardware connection standard
Quasi "(CommercialBuildingTelecommunicationsCablingStandard. BalancedTwisted-
PairTelecommunicationsCablingandcomponentsStandard);
IEEEStd802.3-2008 "communication information between the local network and metropolitan area networks two systems exchange index requirements"
(Telecommunicationsandinformationexchangebetweensystems-Localandmetropoli-
tanareanetworks-Specificrequirements).
This specification is the first release.
Cable network analyzer calibration specification
1 Scope
This standard applies to testing 5,5E, 6 etc. twisted pair cable network analyzer calibration. Testing over 6 category,
7 twisted pair cable network analyzer can use reference.
2. References
TIA-1152 balanced twisted-pair cabling field test instruments and measurement requirements (RequirementsforField
TestInstrumentsandMeasurementsforBalancedTwisted-PairCabling)
For dated references, only the dated edition applies to this specification; undated reference documents
Member, the latest edition (including any amendments) applies to this specification.
3 terminology and units of measurement
3.1 propagation delay propagationdelay
Between the plane of the cable assembly, spread transverse electromagnetic (TEM) waves within the frequency range of each frequency
Phase delay, in nanoseconds (ns).
3.2 NEXT near-endcross-talk, NEXT
A link, send in a line on the cable side, the same side of the other adjacent (receiving) line through
Signal coupling caused by the electromagnetic induction, in decibels (dB).
3.3 ELFEXT equallevelfarandcrosstalk, ELFEXT
A link, send in a line on the cable side, the other side of the other adjacent (receiving) line on
Signal is coupled through electromagnetic induction caused, i.e., far-end crosstalk.
Equivalent far-end crosstalk refers to a distal end of the receiving line crosstalk and signal attenuation on the transmission line to the poor, in minutes
Tony (dB).
4 Overview
Cable network analyzer consists of two parts of the test host and remote. Cable Analyzer host generates a signal, and then
Closing the distal end of the signal sent back for data analysis and processing; of the remote host sends back a response signal.
Network cable analyzer for testing LAN physical layer parameters, the quality of network cabling used in network cabling in advance
Installation or troubleshooting subsequent failure to maintain the network, is a cabling system certification testing to determine its communication and transmission
Analytical instruments necessary to achieve national or international performance standards and use.
Cable network analyzer main digital testing technologies and time domain reflectometry technology to achieve quick test.
5 Metrological characteristics
5.1 DC loop resistance
Measuring range. (0 ~ 50) Ω; maximum permissible error. ± (1% reading 1Ω).
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1494-2014_English be delivered?Answer: Upon your order, we will start to translate JJF 1494-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1494-2014_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1494-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|