US$529.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1491-2014: Calibration Specification for Digital AC Electrical Parameters Meter Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1491-2014 | English | 529 |
Add to Cart
|
4 days [Need to translate]
|
Calibration Specification for Digital AC Electrical Parameters Meter
| Valid |
JJF 1491-2014
|
PDF similar to JJF 1491-2014
Basic data Standard ID | JJF 1491-2014 (JJF1491-2014) | Description (Translated English) | Calibration Specification for Digital AC Electrical Parameters Meter | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A55 | Classification of International Standard | 17.220 | Word Count Estimation | 23,280 | Date of Issue | 11/17/2014 | Date of Implementation | 2/17/2015 | Quoted Standard | JJG 780-1992; GB/T 13978-2008 | Regulation (derived from) | The State Administration of Quality Supervision, Inspection and Quarantine Notice 2014 No. 125 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This Standard applies to the input signal frequency range of 40Hz ~ 1kHz Digital AC parameter measurement instrument, the calibration parameters of the AC portion of the digital display multi-function measuring instrument. |
JJF 1491-2014: Calibration Specification for Digital AC Electrical Parameters Meter---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Digital AC Electrical Parameters Meter
People's Republic of China National Metrology Technical Specifications
Digital AC parameter measurement instrument calibration specification
Issued on. 2014-11-17
2015-02-17 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Digital AC parameter measurement instrument
Calibration Specification
Focal point. the National Technical Committee on Electromagnetic measurement
Drafting. Beijing Institute of Metrology detection
Zhejiang Institute of Metrology
Shandong Province Institute of Metrology
This specification commissioned the National Technical Committee Electromagnetic responsible for the interpretation of measurement
Drafters of this specification.
Gu Yang (Beijing Institute of Metrology detection)
Zheng Mengxia (Zhejiang Institute of Metrology)
Ma Xuefeng (Shandong Province Institute of Metrology)
Huang Yan (Beijing Institute of Metrology detection)
Chen Zhiming (Zhejiang Institute of Metrology)
Lidao Min (Shandong Province Institute of Metrology)
Song Nan (Beijing Institute of Metrology detection)
table of Contents
Introduction Ⅱ
1 Scope 1
2. References 1
3 1 Overview
4 Metrological characteristics 1
5 2 calibration conditions
Environmental Conditions 2 5.1
5.2 Measurement standards and other equipment 2
6 Calibration and Calibration Method 2 project
6.1 Calibration Item 2
6.2 Calibration Method 3
7 Expression 9 calibration results
8 recalibration interval 9
Appendix A Measurement Uncertainty Example 10
12 Appendix B Calibration original record format
Appendix C in the calibration certificate page format (page 2) 14
Appendix D calibration certificate calibration results page format (page 3) 15
Appendix E AC power supply load method calibration error indication 16
Appendix F indication error expression 17
Introduction
This specification based on the national measurement specifications JJF 1071-2010 "National Calibration Specifications writing rules"
JJF 1001-2011 "common measurement terms and definitions", JJF 1059.1-2012 "Measurement Uncertainty Table
Show "establishment.
The specification for the first time to develop.
Digital AC parameter measurement instrument calibration specification
1 Scope
This standard applies to the input signal frequency range of 40Hz ~ 1kHz Digital AC parameter measurement instrument (with
AC calibration parameters portion hereinafter referred to as meter), digital display multi-function measuring instrument.
2. References
This specification refers to the following documents.
JJG780-1992 AC Digital Power Meter
GB/T 13978-2008 DMM
For dated references, only the dated edition applies to this specification; undated reference documents
Member, the latest edition (including any amendments) applies to this specification.
3 Overview
Digital AC parameter measurement instrument is used to measure voltage, current, power, power factor (phase), frequency
And other electrical equipment. Widely used in electrical products, quality control, power line monitoring system, electrical parameter index
The measurement. Electrical parameter measuring instrument block diagram shown in Figure 1, consists of sensors, signal conditioning circuitry, analog to digital conversion
, A control unit, a communication interface and display components.
An electrical block diagram parameter measuring instrument Fig.
4 Metrological characteristics
Indication error of measuring instruments AC voltage, AC current, AC power, frequency, power factor, phase by attaching
Record F calculation, measurement range and the maximum permissible error in Table 1.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1491-2014_English be delivered?Answer: Upon your order, we will start to translate JJF 1491-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1491-2014_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1491-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|