US$509.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1464-2014: Calibration Specification for Interface Tensiometers Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| JJF 1464-2014 | English | 509 |
Add to Cart
|
4 days [Need to translate]
|
Calibration Specification for Interface Tensiometers
| Valid |
JJF 1464-2014
|
PDF similar to JJF 1464-2014
Basic data | Standard ID | JJF 1464-2014 (JJF1464-2014) | | Description (Translated English) | Calibration Specification for Interface Tensiometers | | Sector / Industry | Metrology & Measurement Industry Standard | | Classification of Chinese Standard | A56 | | Classification of International Standard | 17.220 | | Word Count Estimation | 22,282 | | Date of Issue | 6/15/2014 | | Date of Implementation | 9/15/2014 | | Quoted Standard | GB/T 5549-2010; GB/T 6541-1986; GB/T 8170-2008; GB/T 18396-2008; GB/T 22237-2008; SH/T 1156-2014; SY/T 5370-1999; JB/T 9388-2002 | | Regulation (derived from) | The State Administration of Quality Supervision, Inspection and Quarantine Notice No. 64 of 2014 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | | Summary | This standard applies to the use of platinum loop method or the interfacial tension measuring instrument platinum plate method (hereinafter referred to as the tension meter) calibration. |
JJF 1464-2014: Calibration Specification for Interface Tensiometers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Interface Tensiometers
People's Republic of China National Metrology Technical Specifications
Interfacial tension calibration specification
Issued on. 2014-06-15
2014-09-15 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Interfacial tension calibration specification
Focal point. the National Technical Committee on Metering hardness force value
Main drafting unit. China Shipbuilding Industry Corporation seventh hundred and four Institute
Shanghai Institute of Quality Supervision, Inspection
Participated in the drafting unit. Shanghai in the morning Digital Technology Co., Ltd.
Shanghai Measurement and Testing Technology Co., Ltd. Dan FIG.
Chengde Precision Testing Machine Co., Ltd.
This specification entrust national force value hardness measurement technical committee responsible for the interpretation
The main drafters of this specification.
Zhang Guiren (CSIC Institute seventh hundred and four)
Li Tao (China Shipbuilding Industry Corporation seventh hundred and four Research Institute)
Shen Qi (Shanghai Quality Supervision, Inspection Technology Research Institute)
Drafters participate.
Wu Chun Yi (Shanghai in the morning Digital Technology Co., Ltd.)
Xue Feng (Shanghai Measurement and Testing Technology Co., Ltd. Dan FIG)
Zhao Lingyun (Chengde Precision Testing Machine Co., Ltd.)
Qiu Zheng (Shanghai Quality Supervision, Inspection Technology Research Institute)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 terminology and units of measurement (1)
Interface 3.1 (1)
3.2 interfacial tension (1)
4 Overview (1)
4.1 Structure (1)
4.2 Principle (1)
4.3 Purpose (2)
5 Metrological characteristics (2)
Tension 5.1 (2)
5.2 Calculation constants (2)
Calibration Condition 6 (2)
6.1 environmental conditions (2)
6.2 standards and other measuring equipment (2)
7 calibration items and calibration methods (3)
7.1 Calibration tension (3)
7.2 calculate calibration constants (4)
8 calibration results (5)
8.1 Calibration Data Processing (5)
8.2 calibration certificate (5)
9 Recalibration interval (5)
Appendix A tension calibration results table reference the original record format (6)
Appendix B interfacial tension measurements Uncertainty Evaluation Method and Case (7)
Appendix C calibration certificate page format (10)
Appendix D part of the standard technical requirements list (11)
Appendix E major cities in China gravitational acceleration (13)
Appendix F platinum loop, stirrup-shaped ring and a platinum plate shape and size (15)
Introduction
JJF 1071-2010 "National Calibration Specifications writing rules", JJF 1001-2011 "common terminology and measurement
Definitions ", JJF 1059.1-2012" Evaluation and Expression of Uncertainty in Measurement "together constitute the support of the norm-setting work
The basic series of specifications.
The specification for the first time to develop.
Interfacial tension calibration specification
1 Scope
This standard applies to the use of platinum loop method or platinum plate method measuring interfacial tension meter (hereinafter referred to as tension meter) of
calibration.
2. References
This specification refers to the following documents.
Determination of surface tension GB/T 5549-2010 surfactant by drawing up liquid films
GB/T 6541-1986 Petroleum products - Determination of interfacial tension of oil on the water method (ring method)
GB/T 8170-2008 revised value represents about rules and limit values and judgment
GB/T 18396-2008 Determination of surface tension of natural rubber latex Tour de France
GB/Surface active agents surface tension T 22237-2008
Determination of SH/T 1156-2014 synthetic rubber latex surface tension
5370-1999 Surface SY/T and determination of interfacial tension
JB/T 9388-2002 interfacial tension meter technical conditions
For dated references, only the dated edition applies to this specification; undated reference documents
Member, the latest edition (including any amendments) applies to this specification.
3 terminology and units of measurement
3.1 interface interface
Usually refers to the transition zone thickness of about several elements of the two-phase contact, such as the one for the gas phase, this interface is often called
Surface.
3.2 interfacial tension interfacialtension
Along immiscible two-phase (liquid - solid, liquid - liquid, liquid - gas) acting on the interface between the vertical surface of the liquid per unit length
Surface contractile force. Units of mN/m.
4 Overview
4.1 Structure
Tension measured by the tension device, test bench, controlled mobile device and platinum loop, stirrup-shaped ring or platinum plates.
According to the structure can be divided into mechanical and electronic tension meter tension meter types.
4.2 Principle
One method of interfacial tension of two ways platinum loop method or platinum plate can be measured.
4.2.1 platinum loop method
DuNouy known as the Tour de France, the bail law, from the Tour de France. It is measured as follows.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1464-2014_English be delivered?Answer: Upon your order, we will start to translate JJF 1464-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1464-2014_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1464-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|