US$629.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1461-2014: Calibration Specification for Lower Power Transfer Standards Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1461-2014 | English | 629 |
Add to Cart
|
5 days [Need to translate]
|
Calibration Specification for Lower Power Transfer Standards
| Valid |
JJF 1461-2014
|
PDF similar to JJF 1461-2014
Basic data Standard ID | JJF 1461-2014 (JJF1461-2014) | Description (Translated English) | Calibration Specification for Lower Power Transfer Standards | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A56 | Classification of International Standard | 17.220 | Word Count Estimation | 27,273 | Date of Issue | 4/21/2014 | Date of Implementation | 7/21/2014 | Quoted Standard | JJF 1001 | Regulation (derived from) | The State Administration of Quality Supervision, Inspection and Quarantine Notice No. 47 of 2014 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This Standard specifies the frequency range of 100 kHz-50 GHz, power measurement range of 0. 5mW - a variety of low-power 10mW of calibration transfer standards. |
JJF 1461-2014: Calibration Specification for Lower Power Transfer Standards---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Lower Power Transfer Standards
People's Republic of China National Metrology Technical Specifications
Small Power Transfer Standard Calibration Specification
Issued on. 2014-04-21
2014-07-21 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Small Power Transfer Standard Calibration Specification
Focal point. the National Radio Technical Commission metering
The main drafting units. China Aerospace Science and Industry Corporation Second Hospital 203
Participated in the drafting unit. China Institute of Metrology
This specification commissioned the National Radio Technical Commission responsible for the interpretation of measurement
The main drafters of this specification.
ASTRONAUTIC (China Aerospace Science and Industry Corporation hospital 203)
Zhang Weiwei (China Aerospace Science and Industry Corporation hospital 203)
Drafters participate.
Yang Xu Jun (China Aerospace Science and Industry Corporation hospital 203)
Liuxin Meng (China Institute of Metrology)
table of Contents
Introduction (Ⅲ)
1 Scope (1)
2. References (1)
3 terminology and units of measurement (1)
3.1 Terminating Power Standard calibration factor (1)
3.2-through power standard calibration factor (1)
4 Overview (1)
5 Metrological characteristics (1)
Calibration Condition 6 (2)
6.1 Calibration environmental conditions (2)
6.2 Calibration Equipment (2)
7 calibration items and calibration methods (3)
7.1 calibration items (3)
7.2 appearance and working properly check (3)
7.3 transfer standard calibration factors by type of small power (3)
7.4 Terminating small power transfer standard calibration factor (4)
7.5 Terminal Small Power Transfer Standard input reflection coefficient modules (6)
7.6 Transfer standard equivalent source reflection coefficient modules (6) by low-power formula
8 calibration results expression (8)
9 Recalibration interval (8)
Appendix A calibration record format (9)
Appendix B Calibration Certificate-page format (11)
Appendix C Evaluation of Uncertainty in Measurement (13)
Introduction
This specification based JJF 1071-2010 "national measurement calibration specifications write rules" Writing, terminology and measurement
Uncertainty Evaluation follow JJF 1001 "common measurement terms and definitions" and JJF 1059.1 "Measurement Uncertainty
And said, "two documents.
This specification relates primarily small power transfer standard calibration calibration factor and the reflection coefficient modulus values. Alternating Comparison
Law and Standards Act passed the calibration terminal Small Power Transfer Standard calibration factor; uses Terminating Power Standard direct calibration
Pass-through low-power standard calibration factor; a network analyzer calibration terminal Small Power Transfer Standard input
End reflection coefficient modulus.
This specification is the first release.
Small Power Transfer Standard Calibration Specification
1 Scope
This standard applies to the frequency range of 100kHz ~ 50GHz, power measurement range of 0.5mW ~ 10mW
A variety of small power transfer standard calibration.
2. References
This specification refers to the following documents.
JJF 1001 common measurement terms and definitions.
For dated references, only the dated edition applies to this specification; undated reference documents
Member, the latest edition (including any amendments) applies to this specification.
3 terminology and units of measurement
The following definitions of terms apply to this specification.
3.1 Terminating Power Standard calibration factor calibrationfactorofterminatingpowerstandard
DC alternative power Pb incident bolometer element to the seat of power than the power of Pi, by Kb
FIG.
3.2-through power standard calibration factor calibrationfactoroffeedthroughpowerstandard
Next to the directional coupler alternative power Pbc incident arm (or splitters side output terminal) connected to a power seat set
The main arm to the coupler output (or the other side of the splitter output) than non-reflective power Po of the load, with Kc
FIG.
4 Overview
Small Power Transfer Standard is standard equipment for the power value transfer based on their access to the system is not the way
The same is divided into two types by passing a standard formula transfer standard and low-power low-power terminal type.
Small power transfer through a standard thermistor power seat, directional coupler (or power divider) and the power indicator
(Or power bridge) components.
Small Power Transfer Standard Terminal from the power seat and power indicator (or power bridge) composition, or by the formula
Low-power standard output matched load components.
5 Metrological characteristics
a) Frequency range. 100kHz ~ 50GHz;
b) Power measurement range. 0.5mW ~ 10mW;
c) Measurement Uncertainty of calibration factors. 0.6% ~ 5.0% (k = 2);
d) the reflection coefficient modulus value. not more than (0.1 to 0.25).