JJF 1430-2013 English PDF

US$489.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1430-2013: Calibration Specification for X-ray Timers
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1430-2013English489 Add to Cart 4 days [Need to translate] Calibration Specification for X-ray Timers Valid JJF 1430-2013

Standard similar to JJF 1430-2013

JJF 1033   JJF 1050   JJF 1030   

Basic data

Standard ID JJF 1430-2013 (JJF1430-2013)
Description (Translated English) Calibration Specification for X-ray Timers
Sector / Industry Metrology & Measurement Industry Standard
Word Count Estimation 21,292
Quoted Standard GB 9706.3-2000; YY/T 0106-2008
Regulation (derived from) AQSIQ Notice No. 154 of 2013
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies: There are electrical interfaces-x-ray timers calibration.

JJF 1430-2013: Calibration Specification for X-ray Timers

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for X-ray Timers People's Republic of China National Metrology Technical Specifications X-ray calibration timer Specification Issued on. 2013-10-25 2014-01-25 implementation The State Administration of Quality Supervision, Inspection and Quarantine released X-ray calibration timer Specification Focal point. the National Commission on Time and Frequency Measurement Technology Drafting unit. Henan Institute of Metrology Guangxi Academy of measuring and testing This specification entrust national time and frequency measurement technical committee responsible for the interpretation The main drafters of this specification. Cui Guang new (Henan Institute of Metrology) Huangcheng Wei (Henan Institute of Metrology) Full Xueming (Guangxi Institute of measurement detection) Drafters participate. Du Jianguo (Henan Institute of Metrology) Sik Victoria Kennedy (Guangxi Institute of measurement detection)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2. References (1) 3 terminology and units of measurement (1) Irradiation time 3.1 (1) 3.2 Load Time (1) 3.3 Sensitivity (1) 4 Overview (2) 5 Metrological characteristics (2) Interval 5.1 (2) 5.2 pulse count (2) 5.3 Sensitivity (2) Calibration Condition 6 (2) 6.1 environmental conditions (2) 6.2 standards and other measuring equipment (3) 7 calibration items and calibration methods (4) 7.1 visual inspection (4) 7.2 electrical measurement calibration (4) 7.3 X-ray signal measurement calibration (5) 8 calibration results expression (6) 9 Recalibration interval (7) Appendix A calibration certificate page format (8) Appendix B Measurement Uncertainty Evaluation (11) Appendix C reference calibration methods (14) Appendix D load signal sampling method (15)

Introduction

This specification based JJF 1071-2010 "National Calibration Specifications writing rules" establishment. This specification reference to GB 9706.3-2000 "Medical electrical equipment - Part 2. Diagnostic X-ray generator The high-voltage generator for the safety requirements "and YY/T 0106-2008" diagnostic X-ray machine general technical conditions " The technical requirements and load time X-ray timers usually write specifications. The specification for the first time to develop. X-ray timer

1 Scope

This standard applies to electrical signal interface X-ray calibration timer. 2. References This specification refers to the following documents. GB 9706.3-2000 Medical electrical equipment - Part 2. High-voltage generator means of diagnostic X-ray generator Requirements for safety YY/T 0106-2008 medical diagnostic X-ray machine general technical conditions For dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 terminology and units of measurement

3.1 exposure time irradiationtime Also known as the irradiation time. The duration of the irradiation of X-ray machines, usually radiation dose rate exceeds a specified level Room, measuring in milliseconds, a unit symbol ms. Note. the irradiation time is usually based on load time measurements obtained. 3.2 load time loadingtime The positive input power level is applied to the X-ray tube of the time. Usually refers to the first X-ray tube voltage rises to a peak 75% until last fall to the same time interval value only, units of measurement in milliseconds, a unit symbol ms. Note. 1 For a tube or the X-ray tube by using a gate high voltage system load electronic switch control, When you load time can be played in accordance with the limit means limit means generates the load signal is terminated only when the load signal generated from the beginning Intervals to be determined. 2 For a high-voltage circuit in winding or in the X-ray tube filament heating circuit through the analog switch control loading system EC, the loading time can be in accordance with the first X-ray tube current rises to a peak of 25% last played under X-ray tube current A time interval to be determined only when reduced to the same value. 3.3 sensitivity sensitivity X-ray timer can work and meet the requirements of the minimum measurement error in measuring signal values. Note. Minimum input signal amplitude peak to peak X-ray timer square wave, measuring sensitivity refers to a DC electric signal measurement mode ms In volts, unit symbol V; 2 AC electrical sensitivity refers to the input X-ray timer single-phase half-wave rectification or full-wave rectified signal pulse counting mode measurements RMS rectified before the same peak sinusoidal AC electrical signal measurement in volts, unit symbol V; 3 X-ray signal sensitivity ordered X-ray timer can work a minimum X-ray power, measured in units of kV, milli Ann, unit symbol kV, mA.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1430-2013_English be delivered?

Answer: Upon your order, we will start to translate JJF 1430-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1430-2013_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1430-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.