HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (12 Oct 2025)

JJF 1419-2013 English PDF

US$399.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1419-2013: Program of Pattern Evaluation of Buoy Type Oxygen Inhalator
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1419-2013English399 Add to Cart 3 days [Need to translate] Program of Pattern Evaluation of Buoy Type Oxygen Inhalator Valid JJF 1419-2013

PDF similar to JJF 1419-2013


Standard similar to JJF 1419-2013

GB/T 36126   JJF 1368   GB/T 1885   JJF 1414   JJF 1415   JJF 1413   

Basic data

Standard ID JJF 1419-2013 (JJF1419-2013)
Description (Translated English) Program of Pattern Evaluation of Buoy Type Oxygen Inhalator
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A53
Classification of International Standard 17.100
Word Count Estimation 17,135
Quoted Standard JJG 52; JJG 257-2007; JJG 913; YY 1107-2003
Regulation (derived from) ?AQSIQ Announcement 2013 No. 88;
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to patients for emergency medical units for oxygen and oxygen inhalation of hypoxic patients buoy type oxygen inhalation device (hereinafter referred to as inhalers) for type evaluation.

JJF 1419-2013: Program of Pattern Evaluation of Buoy Type Oxygen Inhalator

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Program of Pattern Evaluation of Buoy Type Oxygen Inhalator People's Republic of China National Metrology Technical Specifications Buoy type oxygen inhaler type evaluation outline Issued on. 2013-07-04 2013-10-04 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Buoy type oxygen inhaler type evaluation outline BuoyTypeOxyg enInhalator Focal point. the National Technical Committee of pressure measurement Main drafting unit. Shanghai Institute of Measurement and Testing Participated in the drafting unit. Beijing Institute of Metrology detection This specification commissioned the National Technical Committee of pressure measurement shall be interpreted The main drafters of this specification. Huan Lun (Shanghai Institute of Measurement and Testing) Tu Li Meng (Shanghai Institute of Measurement and Testing) Drafters participate. Hu Haitao (Beijing Institute of Metrology detection)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2. References (1) 3 Overview (1) 4 legal management requirements (1) 4.1 units of measurement (1) 4.2 accuracy class (1) 4.3 legal metrology marking and identification of measuring instruments (1) 4.4 Design of the external structure (2) 4.5 Experimental Prototype (2) 4.6 submit technical data (2) 5 measurement requirements (2) 5.1 Oxygen pressure gauge (2) 5.2 meter (2) 6 General Requirements (3) 6.1 normal operating conditions (3) 6.2 Operating Conditions Reference (3) 6.3 Appearance (3) 6.4 Oxygen pressure gauge (3) 6.5 meter (3) 6.6 Tide bottle (3) 6.7 Working pressure (3) 6.8 sealing (3) 6.9 exhaust pressure relief valve (4) 6.10 Tide bottle compressive strength (4) 6.11 structural strength (4) 7 types of evaluation items (4) 8 Test Conditions and Methods (5) 8.1 test standard (5) 8.2 Test Method (5) Type 9 Judgment principle results (9) Appendix A buoy type oxygen inhaler type evaluation original record format (10)

Introduction

JJF 1002-2010 "national verification procedures write rules", JJF 1001 "common measurement terms and definitions" And JJF 1059 "Evaluation and Expression of Uncertainty in Measurement" together constitute the basic outline of the development of the series specifications. This outline accordance JJG913 "buoy type oxygen inhaler", JJG52 "elastic element type general pressure gauges, pressure Vacuum gauge and vacuum gauge ", JJG257-2007" rotameter "and YY1107-2003" buoy type oxygen absorption Enter "on the content requires compiled, it is possible to buoy type oxygen inhaler performance of an objective, comprehensive and effective Evaluation. The outline of the structure in accordance with JJF 1016-2009 "appliance type evaluation outline guidelines for the preparation of measurement" orchestrated Each chapter in accordance with JJF 1015-2002 "Measuring Instruments type evaluation and type approval of universal norms" and JJF 1002- 2010 provisions "national verification procedures write rules" were prepared. Buoy type oxygen inhaler type evaluation outline

1 Scope

This outline is applied to the patient for emergency medical units for oxygen and hypoxia patient oxygen inhalation buoy type oxygen inhaler (Hereinafter referred to as inhalers) for type approval. 2. References This outline cited the following documents. JJG52 general formula elastic element pressure gauges, pressure vacuum gauge and vacuum gauge JJG257-2007 rotameter JJG913 buoy type oxygen inhaler YY1107-2003 buoy type oxygen inhaler For dated references, only the dated edition applies to this outline; undated reference documents Member, the latest edition (including any amendments) applies to this outline.

3 Overview

Inhaler from the oxygen pressure gauges, flow meters, pressure reducer, safety valve and the influx of bottles composition. Inhaler works. Oxygen cylinders by decompression reducer, from high pressure to low oxygen Pressure of oxygen, and then the flow meter flow control, humidification bottle after the tide, at a constant flow rate value output by the output mouthend, For patient oxygen inhalation.

4 legal management requirements

4.1 units of measurement Inhaler oxygen meter gauge and legal units of measurement should be used. The basic unit of measure commonly used legal arguments Bits and symbols in Table 1. Common legal units of measurement in Table 1 of the basic parameters of the inhaler Quantity Name Unit Symbol Pressure MPa Flow L/min 4.2 accuracy class Inhaler oxygen gauge accuracy rating of 2.5; meter accuracy rating of 4. 4.3 legal metrology marking and measuring instruments logo 4.3.1 legal metrology signs generally include the following. --- Measurement equipment manufacturing license logo and number (test prototype should stay out of the corresponding position); --- Supporting the use of oxygen pressure gauge should obtain measurement equipment manufacturing license;