HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJF 1417-2013 English PDF

US$459.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1417-2013: Program of Pattern Evaluation of Impression Tonometers
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1417-2013English459 Add to Cart 4 days [Need to translate] Program of Pattern Evaluation of Impression Tonometers Valid JJF 1417-2013

PDF similar to JJF 1417-2013


Standard similar to JJF 1417-2013

GB/T 36126   JJF 1368   GB/T 1885   JJF 1414   JJF 1415   JJF 1413   

Basic data

Standard ID JJF 1417-2013 (JJF1417-2013)
Description (Translated English) Program of Pattern Evaluation of Impression Tonometers
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A53
Classification of International Standard 17.100
Word Count Estimation 20,259
Quoted Standard JJG 574-2004; YY 1036-2004
Regulation (derived from) AQSIQ Announcement No. 88, 2013;
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to: indentation tonometer.

JJF 1417-2013: Program of Pattern Evaluation of Impression Tonometers

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Program of Pattern Evaluation of Impression Tonometers People's Republic of China National Metrology Technical Specifications Indentation tonometer type evaluation outline Issued on. 2013-07-04 2013-10-04 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Indentation tonometer type evaluation outline Imp Focal point. the National Technical Committee of pressure measurement The main drafting units. Shandong Institute of Metrology Participated in the drafting unit. China Institute of Metrology Shandong Province Hospital Qianfoshan This specification measured by the National Technical Committee is responsible for interpreting pressure The main drafters of this specification. Ren Hongwei (Shandong Province Institute of Metrology) Qin Xiao Wen (Shandong Province Institute of Metrology) Zhu Jianping (China Institute of Metrology) Sun Jie (China Institute of Metrology) Drafters participate. Lee (Qianfoshan Shandong Province Hospital) Xia Xiao Hong (Shandong Province Institute of Metrology)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2. References (1) 3 Overview (1) 3.1 Purpose and principles (1) 3.2 structure (1) 4 legal management requirements (2) 4.1 Units of measurement requirements (2) 4.2 legal metrology requirements for marking and identification of measuring instruments (2) 4.3 offers the review of technical documents and test prototypes (2) 5 measurement requirements (2) 5.1 Quality deviation (2) 5.2 presser foot tube slide in performance (3) 5.3 Indication deviation (3) 6 General Requirements (3) 6.1 Appearance (3) 6.2 Zero to the positive deviation (4) 6.3 basic size (4) The main parts of the surface roughness of 6.4 (4) 7 types of evaluation items (4) 8 pilot projects test methods and conditions (5) 8.1 Quality deviation (5) 8.2 presser foot sliding performance in the tube (6) 8.3 Indication deviation (7) 8.4 Appearance (7) 8.5 Zero to the positive deviation (8) 8.6 basic size (8) The main parts of the surface roughness of 8.7 (9) 9 type evaluation results to determine (9) 10 original record format type evaluation (9) Appendix A indentation tonometer type evaluation original record format (10)

Introduction

This specification based JJG574 "indentation tonometer", YY1036 "indentation tonometer" developed to JJF 1002 "national verification procedures write rules metering", JJF 1016 "Measuring Instruments type evaluation outline prepared guide Then ", JJF 1015" Measuring Instruments type evaluation and type approval of universal norms "together constitute the support of the norm-setting work As a basic series of documents. This specification is the National Type Evaluation of an outline for the first time established. If the product or the ability to express technical indicators higher than the present syllabus Requirements, technical documents required in accordance with corporate standards, brochures and other verification. Indentation tonometer type evaluation outline

1 Scope

This type of evaluation outline is applied indentation tonometer. 2. References This outline references the following documents. JJG574-2004 indentation tonometer YY1036-2004 indentation tonometer These documents contain provisions which through reference in this syllabus constitute provisions of this outline. For dated references, All subsequent amendments (not including errata content) or revisions do not apply to this syllabus, however, encourage the present Parties to study the outline agreement to use the latest versions of these documents. For undated reference documents, which The latest versions apply to this outline.

3 Overview

3.1 Purpose and principles Indentation tonometer intraocular pressure is a measure of the body of a special instrument. Its working principle is based on a certain quality of the indenter Corneal indentation depth is measured indirectly measured IOP values, each cell size of the scale is equivalent to 0.05mm Corneal indentation depth. Depending on the quality and value of the indentation depth of the indenter and weights, check conversion table to obtain IOP IOP. 3.2 configuration Indentation tonometer by the scale ruler, frame pointer, hammer bow, additional weights, fixed weight, pressure needle, feet Composition pipe and hold handles, etc. Part 9 (Fig. 1). Presser foot move up and down in the tube, press the upper portion of the needle tip was like, it A certain arc hammer bow contacts, formed a pointer deflection displacement transmission mechanism. 1- scale ruler; 2- stent; 3- pointer; 4- hammer bow; 5- Additional weights; 6- fixed weight; 7- presser; 8- foot pipe; 9- holding handle Figure 1 schematic indentation tonometer

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1417-2013_English be delivered?

Answer: Upon your order, we will start to translate JJF 1417-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1417-2013_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1417-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.