US$369.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1402-2013: Calibration Specification for Biological Microscopes Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1402-2013 | English | 369 |
Add to Cart
|
3 days [Need to translate]
|
Calibration Specification for Biological Microscopes
| Valid |
JJF 1402-2013
|
Standard similar to JJF 1402-2013 JJF 1033 JJF 1050 JJF 1030
Basic data Standard ID | JJF 1402-2013 (JJF1402-2013) | Description (Translated English) | Calibration Specification for Biological Microscopes | Sector / Industry | Metrology & Measurement Industry Standard | Word Count Estimation | 16,187 | Quoted Standard | GB/T 2985-2008 | Regulation (derived from) | AQSIQ Announcement No. 63 of 2013 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to: Biological microscope calibration. |
JJF 1402-2013: Calibration Specification for Biological Microscopes---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Biological Microscopes
People's Republic of China National Metrology Technical Specifications
Biological microscope calibration specifications
Issued on. 2013-04-27
2013-07-27 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Biological microscope calibration specifications
es
NFP. National Engineering Geometrical Parameters Measurement Technology Committee
Main drafting unit. Ministry of Industry and Information Technology Electronic five CEPREI measurement test center
Metrology hospital in Guizhou Province
Jiangsu Province Institute of Metrology
Henan Medical Device Testing
Participated in the drafting. Anyang City of Quality and Technical Supervision and Testing Center
This specification project commissioned by the National geometric parameter measurement technology committee responsible for the interpretation
The main drafters of this specification.
Evergreen (Ministry of Industry and Information Technology Electronic five CEPREI measurement test center)
Lv Xiaojie (Guizhou Province Measurement and Testing Institute)
Goal Orientation (Jiangsu Province Institute of Metrology)
Liang Hao Fang (Henan Medical Device Testing)
Drafters participate.
Li Yongjun (Anyang City of Quality and Technical Supervision and Testing Center)
Wang Dongmei (Henan Medical Device Testing)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 Overview (1)
4 Metrological characteristics (2)
4.1 microscope objective magnification error (2)
4.2 binocular microscope system magnification difference of about two (2)
4.3 binocular microscope field of view around the center of the deviation (2)
4.4 Indication error (2)
Calibration Condition 5 (2)
5.1 environmental conditions (2)
5.2 Calibration with standard equipment and the appropriate equipment (2)
6 calibration items and calibration methods (2)
6.1 calibration items (2)
6.2 Calibration method (3)
7 Calibration Results The expression (4)
8 Recalibration interval (5)
Appendix A Error in Measurement Uncertainty Evaluation (6)
Appendix B microscope objective magnification error measuring results Evaluation of Uncertainty (8)
Appendix C calibration certificate content and in-page format (10)
Introduction
JJF 1402-2013 "biological microscope calibration specification" (hereinafter referred to as "the Rules") for biological microscopes
Calibration measurement established technical specifications. Preparation of this specification to JJF 1071-2010 "national measurement calibration specifications prepared by Regulation
Then ", JJF 1001-2011" common measurement terms and definitions "and JJF 1059.1-2012" Measurement Uncertainty assessment
And given that "as the basis and foundation. This specification is the main reference standard GB/T 2985-2008 "biological microscope."
This specification is the first release.
Biological microscope calibration specifications
1 Scope
This standard applies to biological microscope calibration.
2. References
This specification references the following documents.
GB/T 2985-2008 Microscope
For dated references, only the dated edition applies to this specification; undated reference documents
Member, the latest edition (including any amendments) applies to this specification.
3 Overview
Microscope (hereinafter referred to as the "microscope") is an observation and measurement of biological chips, biological cells, bacteria
Measuring the size of the structure, as well as for the living tissue culture, liquid precipitation amount, powder and fine particles size and other parameters
The amount of the instrument. Mainly by the eyepiece, an objective lens, a stage and a mirror (or built-in light and a condenser lens), etc., have
Microscope with an illumination portion (condenser), replace the role of the reflector.
When used, the object to be measured on the microscope stage, adjust the position of the stage by focusing hand wheel, make things
Body microscope eyepiece reticle into a clear image, in order to observe and measure.
Structured into microscope monocular microscope and binocular microscope use is divided into universal microscope, laboratory and research
Study with a microscope. Specific structure shown in Figure 1, Figure 2.
Figure 1 monocular microscope structure Figure 2 binocular microscope Chart
1- eyepiece; 2- eyepiece; 3- nosepiece and the objective lens; 4- stage;
5- lighting or mirror; 6- focusing hand wheel
1- eyepiece; 2- eyepiece; 3- nosepiece and the objective lens; 4- stage;
5- lighting or mirror; 6- move the stage button; 7- focusing hand wheel
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1402-2013_English be delivered?Answer: Upon your order, we will start to translate JJF 1402-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1402-2013_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1402-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|