US$739.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1382-2012: Program of Pattern Evaluation of Flourescence Spectrophotometers Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1382-2012 | English | 739 |
Add to Cart
|
6 days [Need to translate]
|
Program of Pattern Evaluation of Flourescence Spectrophotometers
| Valid |
JJF 1382-2012
|
Standard similar to JJF 1382-2012 JJF 1033 JJF 1050 JJF 1030
Basic data Standard ID | JJF 1382-2012 (JJF1382-2012) | Description (Translated English) | Program of Pattern Evaluation of Flourescence Spectrophotometers | Sector / Industry | Metrology & Measurement Industry Standard | Word Count Estimation | 32,367 | Quoted Standard | JJG 537-2006; GB/T 11606-2007; JB/T 5594-1991 | Regulation (derived from) | AQSIQ Announcement No. 212 of 2012 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard specifies the fluorescence spectrophotometer product classification, requirements, test methods, results processing and decision rules for fluorescence spectrophotometer type evaluation of new products. |
JJF 1382-2012: Program of Pattern Evaluation of Flourescence Spectrophotometers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Program of Pattern Evaluation of Flourescence Spectrophotometers
People's Republic of China National Metrology Technical Specifications
Fluorescence spectrophotometer type evaluation outline
Issued on. 2012-12-21
2013-03-21 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Fluorescence spectrophotometer type evaluation outline
hotometers
Focal point. the National Technical Committee stoichiometric physical
The main drafting units. China Institute of Metrology
Participated in the drafting. Timex Sciences (China) Instrument Co., Ltd.
This specification stoichiometric commissioned National Technical Committee is responsible for the physical interpretation
The main drafters of this specification.
Heya Juan (China Institute of Metrology)
Tao (China Institute of Metrology)
Drafters participate.
Qiu Hailin (Tian Mei (China) Scientific Instruments Ltd.)
table of Contents
Introduction (Ⅲ)
1 Scope (1)
2. References (1)
3 Overview (1)
Technical information and test prototype unit 4 application should be submitted (1)
4.1 Technical Information (1)
4.2 experimental prototype (1)
5 legal management requirements (2)
5.1 Units of measurement requirements (2)
5.2 accuracy requirements (2)
5.3 legal metrology requirements for marking and identification of measuring instruments (2)
5.4 External structural design requirements (2)
5.5 Installation marking requirements (2)
6 measurement requirements (2)
7 General technical requirements (3)
7.1 Appearance and initial inspection (3)
7.2 Insulation resistance test (3)
7.3 dielectric strength test (3)
7.4 adaptive power supply voltage (3)
7.5 High Temperature Test (3)
7.6 Low Temperature Test (3)
7.7 High temperature storage test (3)
7.8 cryogenic storage test (3)
7.9 Damp heat test (3)
7.10 Crash Test (4)
7.11 Drop test (4)
8 pattern evaluation item list (5)
9 type evaluation test methods and conditions of the project (5)
9.1 preparation before the test (5)
9.2 Appearance and initial inspection (5)
9.3 Insulation resistance test (6)
9.4 dielectric strength test (6)
9.5 A Class monochromator wavelength indication error and repeatability (6)
Class 9.6 B monochromator filter peak wavelength indication error test (8)
9.7 Sensitivity test (9)
9.8 Measurement linearity test (10)
9.9 repeatability fluorescence spectrum peak intensity (11)
9.10 stability test (11)
9.11 Working environment test (12)
9.12 storage, transportation and environmental testing (14)
10 determined the type of evaluation results (17)
Appendix A fluorescence spectrophotometer type evaluation original record format (18)
Introduction
This type of evaluation outline evaluation projects. Wavelength indication error, wavelength reproducibility, detection limit, measuring line
, Fluorescence spectral peak intensity repetitive fluorescence intensity upper limit value shown in 10min drift and other technical indicators adopted
JJG537-2006 "fluorescence spectrophotometer" metrics; within 10min zero line drift index using Industry Standard
JB/T 5594-1991 "fluorescence spectrophotometer" in the index; increase the signal to noise ratio in the measurement of performance requirements, because
Indicators for the different requirements of different manufacturers, which indicators to manufacturers declaration or instrument specification is based on indicators; in the pass
Technical requirements increased dielectric strength, the power supply voltage and environmental adaptability of the pilot project, dielectric strength, power supply
Pressure adaptation index using Industry Standard JB/T 5594-1991 "fluorescence spectrophotometer" in the index; Environmental Testing
Mainly related to low temperature test, high temperature test, low temperature storage test, high temperature storage test, alternating hot and humid test, crash test
Test, drop test and other projects, technical requirements and testing methods GB/T 11606-2007 "Environmental analysis instrument test
Test method "in the relevant content.
This type of evaluation outline for the first release.
Fluorescence spectrophotometer type evaluation outline
1 Scope
This type of evaluation outline provides fluorescence spectrophotometer product classifications, requirements, test methods, and results processing
Determine the rules for the new fluorescence spectrophotometer product type evaluation.
2. References
JJG537-2006 fluorescence spectrophotometer
GB/T 11606-2007 analytical instruments environmental test methods
JB/T 5594-1991 fluorescence spectrophotometer
These documents contain provisions which through reference in this syllabus constitute provisions of this outline. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply to this outline, however, the drum
Reed whether the latest versions of these files according to the parties that this outline agreement. Those who do not note cited date
Use, the latest versions apply to this outline.
3 Overview
Fluorescence spectrophotometer (hereinafter referred to as the instrument) from the light source system, excitation monochromator system, sample room, single launch
Color system, the detector system and a data processing system structure. The light emitted by the light source, through the excitation monochromator becomes
After the monochromatic light, according to the fluorescent substance on the test sample cell, thereby excite fluorescence emission monochromator is collected by
Monochromator dispersion into monochromatic light, and fluorescence intensity was measured into an electrical signal by a detector system, the data processing system
And converted into digital spectrum.
For a given material, the intensity of the excitation light and the wavelength is fixed, the fixed thickness of the liquid layer, the concentration of the solution
At lower concentrations the fluorescence intensity F c and the fluorescent substance, the instrument constant k have the following relationship.
F = kc
According to this principle, a fluorescence spectrophotometer can be applied to the determination of the nature and amount of the fluorescent substance.
The instrument can be divided into two categories monochromator. A class is a dispersive monochromator, a class B filter monochromator.
Technical information and test prototype to be submitted by the applicant 4
4.1 Technical Information
4.1.1 the whole picture, assembly diagram, schematic diagram and major components.
4.1.2 Technical Standards Document (including test methods).
4.1.3 product manual.
Test report 4.1.4 manufacturing units or technical bodies prototype made.
4.2 Experimental Prototype
The applicant can apply for a single product and to be filed by product. Where a single product by Shin
Please, under normal circumstances should provide a prototype. By Series application products, each product extracted at least one-third
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1382-2012_English be delivered?Answer: Upon your order, we will start to translate JJF 1382-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1382-2012_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1382-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|