US$369.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1346-2012: Calibration Specification for Infrasonic and Ultrasonic Filters Status: Valid JJF 1346: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1346-2012 | English | 369 |
Add to Cart
|
3 days [Need to translate]
|
Calibration Specification for Infrasonic and Ultrasonic Filters
| Valid |
JJF 1346-2012
|
JJF 1346-1990 | English | 239 |
Add to Cart
|
2 days [Need to translate]
|
(The X-ray energy (60 ~ 250kV) exposure baseline operating technical specifications)
| Obsolete |
JJF 1346-1990
|
PDF similar to JJF 1346-2012
Basic data Standard ID | JJF 1346-2012 (JJF1346-2012) | Description (Translated English) | Calibration Specification for Infrasonic and Ultrasonic Filters | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A59 | Classification of International Standard | 17.140 | Word Count Estimation | 16,188 | Quoted Standard | JJG 449-2001; JJF 1001-2011; JJF 1034-2005; JJF 1059-1999; GB 3102.5-1993; GB 3102.7-1993; ISO 7169-1995 | Regulation (derived from) | State Administration of Quality Supervision, Inspection and Quarantine Notice 2012 No. 63; | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard specifies the frequency range of 1Hz ~ 50Hz and 2kHz ~ 100kHz of infrasound and ultrasound measurement of filter characteristics, calibration conditions and calibration methods. This standard applies to the frequency range of 1Hz ~ 50Hz and |
JJF 1346-2012: Calibration Specification for Infrasonic and Ultrasonic Filters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Infrasonic and Ultrasonic Filters
National Metrological Technical Code of the People's Republic of China
Infrasound and ultrasonic filters
Calibration specification
2012-04-17 release
2012-07-17 Implementation
State Administration of Quality Supervision, Inspection and Quarantine issued
Infrasound and ultrasonic filters
Calibration specification
Coordinate unit. National Acoustics Metrology Technical Committee
Drafting unit. China Shipbuilding Industry Corporation No. 107 Institute
China Institute of Metrology
Hengyang Instrument Electric Equipment Co., Ltd
Hubei Institute of Metrology and Testing Technology
This specification entrusts the National Acoustics Metrology Technical Committee to explain
The drafters of this specification.
Zhu Chuanhuan (China Shipbuilding Industry Corporation No. 701 Institute)
Zhang Hengping (China Shipbuilding Industry Corporation No. 701 Institute)
Tang Jun (China Shipbuilding Industry Corporation No. 701 Institute)
Chen Jianlin (China Institute of Metrology)
Bian Wenping (China Institute of Metrology)
Liu Xiangheng (Hengyang Instrument Electric Equipment Co., Ltd.)
Yao Qiuping (Hubei Institute of Metrology and Testing Technology)
table of Contents
Introduction (II)
1 Scope (1)
2 References (1)
3 terms and units of measurement (1)
3.1 Reference frequency (1)
3.2 Linear operating range (1)
4 Overview (1)
5 Metrological characteristics (2)
5.1 relative attenuation (2)
5.2 Linear Operating Range (2)
6 Calibration conditions (2)
6.1 Environmental conditions (2)
6.2 Standard and other equipment (2)
7 Calibration items and calibration methods (2)
7.1 Calibration items (2)
7.2 Calibration method (3)
8 Calibration results (5)
8.1 Calibration Data Processing (5)
8.2 Calibration Certificate (5)
8.3 Uncertainty of measurement of calibration results (5)
9 re-school time interval (5)
Appendix A Contents of the Calibration Certificate (6)
Appendix B Example of Evaluation of Measurement Uncertainty (9)
Introduction
This specification is based on the preparation of JJF 1071-2010 "national measurement calibration rules for the preparation of rules", the main norms
Reference to JJG449-2001 "octave and 1/3 octave filter" and ISO 7196..1995 "Acoustic infrasound
Measurement of frequency weighting characteristics (Acoustics-Frequency-weightingcharacteristicforinfrasound
measurement.
Secondary and ultrasonic filter calibration specifications
1 Scope
This specification specifies the frequency range of 1Hz ~ 50Hz and 2kHz ~ 100kHz secondary sound and ultrasonic filter
(Hereinafter referred to as the filter) measurement characteristics, calibration conditions and calibration methods.
This specification applies to infrasound and ultrasonic filters with frequency ranges from 1 Hz to 50 Hz and from 2 kHz to 100 kHz
calibration.
2 reference file
This specification refers to the following documents.
JJG449-2001 octave and 1/3 octave filter
Standard Terminology and Definitions for JJF 1001-2011
Terminology and definitions of acoustical metrology nouns JJF 1034-2005
Measurement Uncertainty Evaluation and Representation of JJF 1059-1999
Electrical and magnetic quantities and units GB 3102.5-1993
Acoustics quantities and units
ISO 7196..1995 Acoustics-Frequency-
weightingcharacteristicforinfrasoundmeasurement
For dated references, only the dated edition applies to this specification; references that are not dated
, The latest version (including all modifications) applies to this specification.
3 terms and units of measurement
JJF 1001-2011, JJF 1034-2005, GB 3102.5-1993 and GB 3102.7-1993
The terms, definitions, quantities and units of measurement and the following terms and definitions apply to this specification.
3.1 reference frequency referencefrequencies
In each mode of the filter, within a specified frequency range, a specific frequency for relative attenuation is calculated.
3.2 linear work range linearoperatingrange
For the specified infrasound and ultrasonic filter bandwidth and level range, in the 1Hz ~ 100kHz frequency range of electricity
When the flatness error is within the specified maximum permissible error, the range of the steady-state sinusoidal input signal level, in minutes
Shell (dB).
4 Overview
The infrasound and ultrasonic filter is a filtering device in the infrasound and ultrasonic frequency bands, providing a variety of frequency bands
Filter the information of the spectrum. It can be a component in a measurement system, or it can be a separate instrument. General infrasound and
The ultrasonic filter contains six different modes, namely Ultrasound (Ult), Ultrasound Weighting (U1), Audio (U), Infrasound
(Infra), infrasound weighting 1 (G1), infrasound weighted 2 (G2), they play a different band of filtering.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1346-2012_English be delivered?Answer: Upon your order, we will start to translate JJF 1346-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1346-2012_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1346-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJF 1346-2012?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1346-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|