Calibration Specification for Transducers of Ultrasonic Flaw Detector
| Valid |
JJF 1294-2011
|
JJF 1294-1990 | English | 319 |
Add to Cart
|
3 days [Need to translate]
|
O.T.N. for Primary Standard of Magnetic Induction
| Obsolete |
JJF 1294-1990
|
PDF similar to JJF 1294-2011
Basic data Standard ID | JJF 1294-2011 (JJF1294-2011) | Description (Translated English) | Calibration Specification for Transducers of Ultrasonic Flaw Detector | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A59 | Classification of International Standard | 17.140 | Word Count Estimation | 15,145 | Date of Issue | 2011-07-04 | Date of Implementation | 2011-10-04 | Quoted Standard | JJF 1001-1998; JJF 1034-2005; JJF 1059-1999; GB 3102.7-1993; GB/T 12604.1-2005; GB/T 18694-2002; EN 12668-2-2001 | Regulation (derived from) | AQSIQ Announcement No. 104 of 2011 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard specifies the type A display of ultrasonic flaw detector transducer (also known as probe) measurement characteristics, calibration conditions and handsome registration method. This standard applies to the center frequency in the range 0. 5MHz ~ 15MHz probe calibration. |
JJF 1294-2011: Calibration Specification for Transducers of Ultrasonic Flaw Detector---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Transducers of Ultrasonic Flaw Detector
People's Republic of China National Metrology Technical Specifications
Ultrasonic flaw detector transducer calibration specification
Issued on. 2011-07-04
2011-10-04 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Ultrasonic flaw detector transducer
Calibration Specification
This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on July 4, 2011, and from
From October 4, 2011 implementation.
Focal point. the National Committee of the acoustic measurement technology
Main drafting unit. Jilin Institute of Metrology
Shantou Institute of Ultrasonic Instruments Co., Ltd.
Participated in the drafting unit. Institute of Measurement and Detection Guangzhou
This specification metering commissioned National Technical Committee is responsible for interpreting acoustics
The main drafters of this specification.
Room-laid (Jilin Institute of Metrology)
Yan surplus (Jilin Institute of Metrology)
Wang Xingxiong (Shantou Institute of Ultrasonic Instruments Co., Ltd.)
Drafters participate.
Han Xiaofei (Jilin Institute of Metrology)
Zhou Changhua (Guangzhou Institute of Measurement and Detection)
table of Contents
1 Scope (1)
2. Referenced Documents (1)
3 terminology and units of measurement (1)
3.1 Relative pulse-echo sensitivity (1)
3.2 angle probe incident point (1)
4 Overview (1)
5 Metrological characteristics (2)
Pulse width 5.1 (2)
The center frequency of 5.2 (2)
Relative bandwidth 5.3 (2)
5.4 Relative pulse-echo sensitivity (2)
5.5 angle probe incident point (2)
5.6 angle probe beam angle (2)
Calibration Condition 6 (2)
6.1 environmental conditions (2)
6.2 Standard device and main equipment (2)
7 calibration items and calibration methods (3)
7.1 calibration items (3)
7.2 Calibration method (3)
8 calibration results expression (6)
8.1 Calibration Data Processing (6)
8.2 calibration certificate (6)
8.3 Calibration of Uncertainty Evaluation (6)
9 Recalibration interval (6)
Appendix A recommended calibration certificate contents (7)
Appendix B Uncertainty evaluation calibration results of examples (9)
Ultrasonic flaw detector transducer calibration specification
1 Scope
This specification defines the A-type ultrasonic flaw detector display transducer (also called probes) the metrological characteristics, calibration strip
Member and calibration methods.
This standard applies to the center frequency calibration of the probe within the 0.5MHz ~ 15MHz range.
2 Citations
This specification refers to the following documents.
JJF 1001-1998 common measurement terms and definitions
JJF 1034-2005 acoustic measurement terminology and definitions
JJF 1059-1999 Evaluation and Expression of Uncertainty in Measurement
GB 3102.7-1993 Quantities and units of acoustics
GB/T 12604.1-2005 Terminology for nondestructive testing Ultrasonic testing
Characterization of GB/T 18694-2002 Ultrasonic inspection and sound field
EN12668-2.2001 Non-destructive testing and performance testing - Ultrasonic testing equipment - Part 2. Probe
(Non-destructivetesting-Characterizationandverificationofultrasonicexamination
equipment-Part 2. Probes)
When using this specification it should be noted that using the currently valid version of the documents cited.
3 terminology and units of measurement
This specification uses quantities and units specified in GB 3102.7-1993. This specification uses JJF 1001-1998,
JJF 1034-2005, GB/T 12604.1-2005 as defined in the following terms and definitions.
3.1 Relative pulse-echo sensitivity relativepulseechosensitivity
From the specified reflector zoom back before the peak - peak-to-peak voltage applied on the probe - the ratio of peak voltage.
NOTE. pulser/receiver set single transmit/receive mode, the relative sensitivity of the pulse-echo the formula shown in Equation (1).
Srel = 20lg (Ue/Ua) (1)
Where.
Srel --- Relative pulse-echo sensitivity, dB;
Ue --- from the specified reflector zoom back before the peak - peak voltage, V;
Ua --- applied to the peak on the probe - peak voltage, V.
3.2 points angleprobeindex incident angle probe
Beam axis through the bottom surface of the probe point.
Note. This point is usually the side with the probe indicates scale reading.
4 Overview
Ultrasonic flaw detector transducer is in the ultrasonic frequency range to convert electrical energy into mechanical energy and/or mechanical energy is converted into
|