HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJF 1293-2011 English PDF

US$419.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1293-2011: Calibration Specification for Electrostatic Actuators
Status: Valid

JJF 1293: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1293-2011English419 Add to Cart 3 days [Need to translate] Calibration Specification for Electrostatic Actuators Valid JJF 1293-2011
JJF 1293-1990English239 Add to Cart 2 days [Need to translate] O. T. N. for Primary Standard of Dissipation Factor of Capacitor (explanation) Obsolete JJF 1293-1990

PDF similar to JJF 1293-2011


Standard similar to JJF 1293-2011

JJF 1234   JJF 1366   JJG 376   JJF 2000   JJF 1285   JJF 1284   

Basic data

Standard ID JJF 1293-2011 (JJF1293-2011)
Description (Translated English) Calibration Specification for Electrostatic Actuators
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A55
Word Count Estimation 18,169
Date of Issue 2011-07-04
Date of Implementation 2011-10-04
Quoted Standard JJF 1001-1998; JJF 1034-2005; JJF 1059-1999; JJG 449-2001; JJG 790-2005; GB/T 3102.7-1993; IEC 61094-6-2004
Regulation (derived from) AQSIQ Announcement No. 104 of 2011
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard provides for the determination of the frequency response of the microphone electrostatic actuator metrological characteristics, calibration conditions and calibration methods. This standard applies to the determination of the frequency response of the microphone electrostatic actuator calibration.

JJF 1293-2011: Calibration Specification for Electrostatic Actuators

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Electrostatic Actuators People's Republic of China National Metrology Technical Specifications Electrostatic actuator calibration specification Issued on. 2011-07-04 2011-10-04 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Electrostatic actuator calibration specification This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on July 4, 2011, and from From October 4, 2011 into effect. Focal point. the National Committee of the acoustic measurement technology Drafting units. China Institute of Metrology Hengyang Heng Electric Instrument Co., Ltd. Application of Shaanxi Normal University Institute of Acoustics This specification metering commissioned National Technical Committee is responsible for interpreting acoustics Drafters of this specification. He Longbiao (China Institute of Metrology) Liu Xiangheng (Hengyang Heng Instrument Electric Co., Ltd.) Chen Jianlin (China Institute of Metrology) Niu Feng (China Institute of Metrology) Sheng-lift (Shaanxi Normal applications Acoustics)

table of Contents

1 Scope (1) 2. Referenced Documents (1) 3 terminology and units of measurement (1) 4 Overview (1) 5 Metrological characteristics (2) 5.1 electrostatic actuator response repeatability (2) 5.2 electrostatic actuator in response to sound pressure level and the difference between the response level of consistency (2) Calibration Condition 6 (2) 6.1 environmental conditions (2) 6.2 Standard device and other equipment (2) 7 calibration items and calibration methods (3) 7.1 calibration items (3) 7.2 Calibration method (3) 8 calibration results expression (4) 8.1 Calibration records (4) 8.2 Calibration Data Processing (4) 8.3 calibration certificate (5) 8.4 Calibration of Uncertainty Evaluation (5) 9 Recalibration interval (5) Appendix A calibration certificate (6) Appendix B Uncertainty evaluation calibration results of examples (8) Electrostatic actuator calibration specification

1 Scope

This specification defines the metrological characteristics for measuring the frequency response of the microphone electrostatic actuator, calibration conditions and calibration method. This standard applies to the determination of the microphone frequency response of electrostatic actuator calibration.

2 Citations

This specification references the following documents JJF 1001-1998 common measurement terms and definitions JJF 1034-2005 acoustic measurement terminology and definitions JJF 1059-1999 Evaluation and Expression of Uncertainty in Measurement JJG449-2001 octave and 1/3 octave filters JJG790-2005 laboratory standard microphones (coupling cavity Reciprocity Method) GB/T 3102.7-1993 Quantities and units of acoustics IEC 61094-6.2004 Measurement microphones - Part 6. Measuring the frequency response of the electrostatic actuator (Meas- urementmicrophones-Part 6. Electrostaticactuatorsfordeterminationoffrequencyre- sponse) When using this specification it should be noted that using the currently valid version of the documents cited.

3 terminology and units of measurement

This specification uses terminology and definitions relating to the JJF 1001-1998 and JJF 1034-2005. This specification uses quantities and units GB/T 3102.7-1993 prescribed. According to the specification requires, references IEC 61094-6 the following terms and definitions. Microphone static actuator response electrostaticactuatorresponseofamicrophone With specially designed by the amplitude-frequency characteristics of a uniform electrostatic actuator drive voltage measured with respect to a predetermined frequency The rate of output, the output frequency of the function represented by the microphone. Note. The static actuator response in decibels (dB).

4 Overview

Determination of the electrostatic actuator is the frequency response of the microphone apparatus is used, consisting of a rigid conductive flat plates. The flat Microphone diaphragm plate is located, AC voltage is applied between the plate and the diaphragm signal generating static electricity to all simulation Uniform distribution of sound pressure on the surface of the membrane, which is the fundamental frequency of the sound pressure p root mean square value of the available formula (1). p = εgasad2U0u (1) Where. p --- fundamental frequency sound pressure root mean square value, in Pa (Pa);

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1293-2011_English be delivered?

Answer: Upon your order, we will start to translate JJF 1293-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1293-2011_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1293-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJF 1293-2011?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1293-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.