US$349.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1273-2011: Calibration Specification for Magnetic Particle Flaw Detectors Status: Valid JJF 1273: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1273-2011 | English | 349 |
Add to Cart
|
3 days [Need to translate]
|
Calibration Specification for Magnetic Particle Flaw Detectors
| Valid |
JJF 1273-2011
|
JJF 1273-1990 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
(High frequency (0.1 ~ 5MHz) sound pressure water base operating technical specifications)
| Obsolete |
JJF 1273-1990
|
PDF similar to JJF 1273-2011
Basic data Standard ID | JJF 1273-2011 (JJF1273-2011) | Description (Translated English) | Calibration Specification for Magnetic Particle Flaw Detectors | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A55 | Classification of International Standard | 17.220 | Word Count Estimation | 15,181 | Date of Issue | 2011-01-21 | Date of Implementation | 2011-04-21 | Quoted Standard | JJF 1001-1998; JJF 1059-1999; GB/T 5097-2005; GB/T 15822.3-2005; JB/T 4730.4-2005; JB/T 7406-1994; JB/T 8290-1998 | Regulation (derived from) | AQSIQ Announcement No. 15 of 2011 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to AC, DC (half-wave rectifier or a full-wave rectifier) ??magnetic particle inspection machine calibration. This specification does not apply to electromagnetic yoke flaw detector (instrument), rotating magnetic field detection machine (instrument), etc. yoke magnetic particle inspection machine (meter) calibration. |
JJF 1273-2011: Calibration Specification for Magnetic Particle Flaw Detectors---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Magnetic Particle Flaw Detectors
People's Republic of China National Metrology Technical Specifications
Magnetic particle testing machine calibration specification
Issued on. 2011-01-21
2011-04-21 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Magnetic particle testing machine calibration specification
Mag
This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on January 21, 2011, and from
From April 21, 2011 into effect.
Focal point. the National Technical Committee on Electromagnetic measurement
Main drafting unit. Jiangsu Province Institute of Metrology
China Testing Technology Research Institute
Participated in the drafting unit. Xinjiang Institute of Measurement and Testing
Heilongjiang Provincial Institute of Metrology
Nanjing East electrical detection equipment Ltd.
This specification commissioned the National Technical Committee Electromagnetic responsible for the interpretation of measurement
The main drafters of this specification.
Fan Yi (Jiangsu Province Institute of Metrology)
Shen Jian (China Testing Technology Research Institute)
Drafters participate.
Full Song (Xinjiang Institute of Measurement and Testing)
Chang Group (Heilongjiang Institute of Metrology)
Li Lin (Jiangsu Province Institute of Metrology)
Gao Jie (Jiangsu Province Institute of Metrology)
Zeng German (Nanjing East Power Detection Equipment Co., Ltd.)
table of Contents
1 Scope (1)
2. References (1)
3 terminology and units of measurement (1)
4 Overview (1)
5 Metrological characteristics (2)
5.1 magnetizing current (2)
5.2 residual magnetic flux density (2)
5.3 viewing conditions (2)
5.4 Safety Performance (2)
Integrated Sensitivity 5.5 (2)
6 calibration conditions (3)
Environmental conditions 6.1 (3)
6.2 standards and other measuring equipment (3)
7 calibration items and calibration methods (3)
7.1 calibration items (3)
7.2 Calibration method (4)
8 calibration results expression (5)
9 Recalibration interval (6)
Types Appendix A standard test piece, specifications list (7)
Appendix B magnetic particle inspection machine calibration original records (8)
Appendix C magnetic particle inspection machine calibration certificate (report) within the page format (10)
Magnetic particle testing machine calibration specification
1 Scope
This standard applies to AC, DC (half-wave rectification or full-wave rectification) magnetic particle inspection machine (hereinafter referred to as testing machine)
Calibration. This specification does not apply to electromagnetic yoke flaw detector (instrument), a rotating magnetic field detection machine (instrument) and other yoke type magnetic probe
Injury (device) calibration.
2. References
This specification references the following documents.
JJF 1001-1998 common measurement terms and definitions
JJF 1059-1999 Evaluation and Expression of Uncertainty in Measurement
GB/T 5097-2005 destructive testing - Penetrant testing and magnetic particle testing - Viewing conditions
GB/T 15822.3-2005 destructive testing - Magnetic particle testing - Part 3. Equipment
JB/T 4730.4-2005 pressure equipment Non-destructive testing - Part 4. Magnetic particle testing
JB/T 7406-1994 term testing machine nondestructive testing equipment
JB/T 8290-1998 magnetic particle inspection machine
When using this specification should be taken in the current valid version of the above referenced files.
3 terminology and units of measurement
3.1 weeks magnetization current circumferentialmagnetizingcurrent
Circumferentially magnetizing current is the current carrying conductor directly to the workpiece as produced. The current causes a workpiece
Surround the workpiece and the workpiece and the vertical magnetic field circumferentially closed for discovering the workpiece axially parallel defects (longitudinal flaws).
3.2 longitudinal magnetization current lengthwisemagnetizingcurrent
Longitudinal magnetization current is the current through the magnetizing coils surround the workpiece. The current in the coil generates a magnetic field
Magnetization of the workpiece, whose lines of flux parallel to the axial direction of the workpiece, and the workpiece to detect defects perpendicular to the axial
(Transverse defects).
Note. The vertical magnetizing current meter ampere-turns generally longitudinal magnetization coil turns provided by the manufacturer.
4 Overview
After the ferromagnetic material is magnetized workpiece, when the workpiece is defective, causing the magnetic field is not continuous, so that the surface
And near the surface of the magnetic field lines generated by localized distortion leakage magnetic field applied to the magnetic surface adsorption in suitable
The formation of the light indications visual evidence to show the location, size, shape and severity of defects in the workpiece. flaw detection
Machine is manufactured based on the above principle non-destructive testing equipment.
Testing machine is generally divided into two kinds of fixed and mobile, is based on the principle of variable current source constructed. Stationary
Testing machines generally can simultaneously generate longitudinal and circumferential magnetization current magnetizing current, there are two current loop. Mobile testing machine
Usually only one set of current loop. Its type, and other specifications are shown in Table 1.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1273-2011_English be delivered?Answer: Upon your order, we will start to translate JJF 1273-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1273-2011_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1273-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJF 1273-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1273-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|