US$579.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1262-2010: Calibration Specification for Sheathed Thermocouples Status: Valid JJF 1262: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1262-2010 | English | 579 |
Add to Cart
|
5 days [Need to translate]
|
Calibration Specification for Sheathed Thermocouples
| Valid |
JJF 1262-2010
|
JJF 1262-1990 | English | 239 |
Add to Cart
|
2 days [Need to translate]
|
O.T.N. of the Secondary Standard for Middle frequency Vibration
| Obsolete |
JJF 1262-1990
|
PDF similar to JJF 1262-2010
Basic data Standard ID | JJF 1262-2010 (JJF1262-2010) | Description (Translated English) | Calibration Specification for Sheathed Thermocouples | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A54 | Classification of International Standard | 17.200 | Word Count Estimation | 25,230 | Date of Issue | 2010-09-06 | Date of Implementation | 2010-12-06 | Quoted Standard | GB/T 18404-2001; GB/T 16839.1-1997; GB/T 16839.2-1997; GB/T 4989-1994 | Regulation (derived from) | AQSIQ Announcement No. 100 of 2010 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to measuring range (-40 ~ 1100)��C, metal sleeve length not less than 500mm of inexpensive metal sheathed thermocouple calibration. |
JJF 1262-2010: Calibration Specification for Sheathed Thermocouples---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Sheathed Thermocouples
People's Republic of China National Metrology Technical Specifications
Sheathed thermocouple calibration specification
Issued on. 2010-09-06
2010-12-06 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Sheathed thermocouple calibration specification
les
This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on September 6, 2010, and from
From December 6, 2010 into effect.
Focal point. the National Technical Committee of temperature measurement
Main drafting unit. Liaoning Provincial Institute of Metrology
Participated in the drafting. Northeastern University
Dandong City Institute of Measurement and Testing Technology
Jinzhou City metrological verification tests
This specification temperature measured by the National Technical Committee is responsible for interpretation
The main drafters of this specification.
Hou Sulan (Liaoning Provincial Institute of Metrology)
Xu Hongguang (Liaoning Provincial Institute of Metrology)
Xing Zhihong (Liaoning Provincial Institute of Metrology)
Drafters participate.
Wang Hao (Northeastern University)
Song Guangyuan (Institute of Measurement and Testing Technology Dandong City)
Zhao Yuzhu (Jinzhou City metrological verification tests)
table of Contents
1 Scope (1)
2. Referenced Documents (1)
3 Overview (1)
4 Metrological characteristics (1)
4.1 Insulation resistance at room temperature (1)
4.2 shows the value of tolerance (1)
Calibration Condition 5 (2)
5.1 environmental conditions (2)
5.2 Calibration with standard equipment and ancillary equipment (2)
6 calibration items and calibration methods (3)
6.1 calibration items (3)
6.2 Calibration method (4)
6.3 Data Processing (5)
Expression 7 Calibration results (5)
8 recalibration intervals (6)
Appendix A to select the calibration reference temperature sheathed even point (7)
Appendix B sheathed thermocouple thermal emf and the deviation of the indexing table is calculated (8)
Appendix C sheathed thermocouple calibration records reference format (11)
Appendix D sheathed thermocouple calibration reference format (13)
Appendix EK, N, E, J, T-type sheathed thermocouple thermal emf tolerance table (14)
Appendix FK, N, E, J, T-type thermocouples Baidu whole point differential thermal electromotive force table (16)
Appendix G sheathed thermocouple thermal emf measurements Uncertainty Evaluation Examples (17)
Sheathed thermocouple calibration specification
1 Scope
This standard applies to the measurement range (-40 ~ 1100) ℃, the metal sleeve length not less than 500mm inexpensive metal
Sheathed thermocouple calibration.
2 Citations
GB/T 18404-2001 sheathed thermocouple cables and thermocouples
GB/T 16839.1-1997 Thermocouples - Part 1. indexing table
GB/T 16839.2-1997 Thermocouples - Part 2. Tolerances
GB/T 4989-1994 thermocouple compensation wire
When using this specification it should be noted that using the currently valid version of the documents cited.
3 Overview
Sheathed thermocouple (hereinafter referred to as sheathed thermocouple) thermocouple wire is insulated with inorganic, metallic armor casing package
Even cable installation made for a variety of industrial process temperature measurement thermocouple. By measuring the form of the end structure is divided into insulation
Type, exposed junction type, then shell and separate insulated. Material divided by the temperature sensing element armor nickel-chromium - nickel silicon thermocouple
(K type), armored nickel-chromium silicon - Ni-Si-Mg thermocouple (N-type), armored nickel-chromium - copper-nickel thermocouple (E-type), armored iron - copper
Ni thermocouple (J-type) and armored copper - copper-nickel thermocouple (T type).
4 Metrological characteristics
4.1 Insulation resistance at room temperature
Armored dual temperature insulation resistance should be consistent with Table 1.
Table 1 armored dual temperature insulation resistance
project
Test temperature
No indexing the minimum insulation resistance length
(20 ± 15) ℃ K, N, E, J, T
Not less than 1m Rr · L≥1000MΩ · m
Less than 1m Rr≥1000MΩ
4.2 Indication Tolerance
Indication armor even tolerance shown in Table 2.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1262-2010_English be delivered?Answer: Upon your order, we will start to translate JJF 1262-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1262-2010_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1262-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJF 1262-2010?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1262-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|