HOME   Cart(1)   Quotation   About-Us Tax PDFs Standard-List
Powered by Google-Search & Google-Books www.ChineseStandard.net Database: 189760 (18 Mar 2023)

JJF 1175-2007

JJF 1175-2007_English: PDF (JJF1175-2007)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)Related StandardStatusPDF
JJF 1175-2007English479 Add to Cart 4 days Calibration Specification for Test Sieves JJF 1175-2007 Valid JJF 1175-2007

BASIC DATA
Standard ID JJF 1175-2007 (JJF1175-2007)
Description (Translated English) Calibration Specification for Test Sieves
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A28
Classification of International Standard 19.120
Word Count Estimation 20,237
Date of Issue 2007-02-28
Date of Implementation 2007-05-28
Quoted Standard AQSIQ Announcement No. 41 of 2007
Drafting Organization Metrological Verification and Testing Institute of Heilongjiang Province
Administrative Organization National Engineering Measurement Technical Committee of Geometrical parameters
Regulation (derived from) AQSIQ Announcement No. 41 of 2007
Issuing agency(ies) State Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to size (0. 020 ~ 125) mm wire braid, (1 ~ 125) mm perforated metal plate test sieve calibration.

JJF 1175-2007
Calibration Specification for Test Sieves
People's Republic of China National Metrology Technical Specifications
Test sieve calibration specifications
Posted 2007-02-28
2007-05-28 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Test sieve calibration specifications
CalibrationSp
This specification by the State Administration of Quality Supervision, Inspection and Quarantine, 2007 February 28 ratification and
From May 28, 2007 into effect.
NFP. National Engineering Geometrical Parameters Measurement Technology Committee
Main drafting unit. Heilongjiang Provincial Academy of verification test
Shaanxi Provincial Institute of Metrology
Participated in the drafting unit. Hebei Institute of Metrology
Henan Institute of Measurement and Testing
Measurement Science and Technology Institute in Fujian Province
This specification shall be interpreted by the focal point
The main drafters of this specification.
Zhang Liping (Heilongjiang Provincial Academy of verification test)
Zhang Lei (Shaanxi Provincial Institute of Metrology)
Liang Yuhong (Heilongjiang Provincial Academy of verification test)
Drafters participate.
Wang Shaoping (Hebei Institute of Metrology)
Gu Xiaojie (Henan Institute of Measurement and Testing)
Liao Yi water (Fujian Institute of Measurement Science Technology)
Xiaoliang (Heilongjiang Provincial Academy of verification test)
table of Contents
1 Scope (1)
2. Referenced Documents (1)
3 Terms and Definitions (1)
Sieving 3.1 (1)
3.2 sieve size analysis (1)
4 Overview (1)
5 Metrological characteristics (1)
5.1 Test sieves of metal wire cloth (1)
5.2 Test sieves of perforated metal plate (7)
6 calibration conditions (9)
Environmental conditions 6.1 (9)
6.2 be corrected test sieve should have the conditions (9)
6.3 calibration equipment (9)
7 calibration items and calibration methods (9)
7.1 woven wire mesh calibration test pore size (9)
7.2 perforated metal plate calibration test sieve mesh size (10)
8 calibration results expression (10)
9 Recalibration interval (10)
Uncertainty Analysis Appendix A woven wire mesh sieve size sieve test measurements (11)
Appendix B Test sieves of perforated metal mesh size measurement uncertainty analysis (13)
Appendix C calibration certificate contents (15)
Test sieve calibration specifications
1 Scope
This instruction applies to size (0.020 ~ 125) mm wire braid, (1 ~ 125) mm metal
Perforated plate test sieve calibration.
2 Citations
This specification references the following documents.
JJF 1001-1998 common measurement terms and definitions
JJF 1059-1999 Evaluation and Expression of Uncertainty in Measurement
JJF 1094-2002 measuring instrument characteristics assessed technical specifications
JJF 1130-2005 geometric measurement equipment calibration Uncertainty Evaluation Guide
GB/T 5329-2003 term test sieves and screening tests
GB/T 6003.1-1997 Test sieves of metal wire cloth
GB/T 6003.2-1997 Test sieves of perforated metal plate
Basic dimensions GB/T 6005-1997 Test sieves - Metal wire cloth, perforated plate and electroformed sheet mesh
ISO 2395-1990 term test sieves and screening tests
When using this specification it should be noted that using the currently valid version of the documents cited.
3 Terms and Definitions
3.1 sieve (sieving)
With one or more sieves having different particle sizes of discrete particles size by size material separation process.
3.2 sieve size analysis (sizeanalysisbysieving)
By sieving the sample was divided into different levels of granularity and report the results.
4 Overview
Test sieve is used for screening particulate material having a particle size sieve analysis. It is widely used in geological exploration, metallurgy,
Chemical, pharmaceutical, building materials, abrasive and other industries as well as research institutes particle size analysis and screening tests.
Complete test sieve and covered by a number of different mesh size sieve, splice tray, as shown in Fig. metal