HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

JG/T 442-2014 English PDF

US$1129.00 · In stock
Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email.
JG/T 442-2014: Irradiation crosslinking low-smoke halogen-free flame retardant power cables with double-layer extrusion insulation of rated voltage 0.6/1 kV
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JG/T 442-2014English1129 Add to Cart 7 days [Need to translate] Irradiation crosslinking low-smoke halogen-free flame retardant power cables with double-layer extrusion insulation of rated voltage 0.6/1 kV Valid JG/T 442-2014

PDF similar to JG/T 442-2014


Standard similar to JG/T 442-2014

GB/T 2951.21   GB/T 2951.11   GB/T 3048.1   JGJ/T 442   JG/T 538   JG/T 441   

Basic data

Standard ID JG/T 442-2014 (JG/T442-2014)
Description (Translated English) Irradiation crosslinking low-smoke halogen-free flame retardant power cables with double-layer extrusion insulation of rated voltage 0.6/1 kV
Sector / Industry Building & Construction Industry Standard (Recommended)
Classification of Chinese Standard K13
Classification of International Standard 29.060.20
Word Count Estimation 46,449
Date of Issue 9/11/2014
Date of Implementation 2/1/2015
Quoted Standard GB/T 1408.1-2006; GB/T 1410-2006; GB/T 2406.2-2009; GB/T 2900.10; GB/T 2951.11-2008; GB/T 2951.12-2008; GB/T 2951.13-2008; GB/T 2951.14-2008; GB/T 2951.21-2008; GB/T 2951.31-2008; GB/T 3048.4-2007; GB/T 3048.8; GB/T 3048.9; GB/T 3048.10; GB/T 3082; GB/T 3
Regulation (derived from) People's Republic of China Ministry of Housing and Urban-Rural Development Notice No. 551
Issuing agency(ies) Ministry of Housing and Urban-Rural Development of the People's Republic of China
Summary This Standard specifies the rated voltage of 0.6/1kV extruded double insulated irradiation crosslinked low-smoke halogen-free flame retardant, fire-resistant power cable terminology and definitions, classification and marking, general provisions, requirem

JG/T 442-2014: Irradiation crosslinking low-smoke halogen-free flame retardant power cables with double-layer extrusion insulation of rated voltage 0.6/1 kV


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Irradiation crosslinking low-smoke halogen-free flame retardant power cables with double-layer extrusion insulation of rated voltage 0.6/1 kV ICS 29.060.20 K13 People's Republic of China building industry standards Rated voltage 0.6/1kV double co-extruded insulation Radiation cross-linked halogen-free low smoke flame retardant power cables with double-layerextrusioninsulationofratedvoltage0.6/1kV 2014-09-11 released 2015-02-01 implementation Ministry of Housing and Urban-Rural Development, People's Republic of China released Directory Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 classification and marking 3 5 General Provisions 5 6 requests 7 7 Test methods 11 8 test 15 9 logo, packaging, transportation and storage 17 Appendix A (Normative) Insulation material mechanical and electrical properties 19 Appendix B (Normative) Aluminum alloy armored with interlocking technical requirements 21 Appendix C (Normative) Sheath material mechanical properties and electrical properties 22 Appendix D (Informative) Calculation of circuit carrying capacity and conductor cross-sectional area of 24 Appendix E (Informative) Cable Reference Current 26 Appendix F (Informative) Creep test method Annex G (Normative) Interlocking armor layer tightness test 31 Appendix H (Normative) Interlocking armor tensile and elongation test 32 Appendix I (Normative) Crush test at room temperature 34 Appendix J (Normative) Impact test at room temperature 35 Appendix K (Informative) Carrying capacity test 36

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard proposed by the Ministry of Housing and Urban Standard and Design Institute. This standard by the Ministry of Housing and Urban Construction Electric Standardization Technical Committee. This standard is drafted by. Shandong Hualing Cable Co., Ltd. Participated in the drafting of this standard. National Quality Supervision and Inspection Center for Wire and Cable, Architectural Design and Research Institute of Shandong Province, Jinan City Public Security Fire Detachment, Zhejiang Wanma Cable Co., Ltd., Hebei Jinqiao Cable Co., Ltd. The main drafters of this standard. Wang Zhaobo, Pan Mao Long, Li Guangjie, Song Huai Xu, Wang Qingbao, Xiao Jidong, Wu Enyuan, Fu Ping, Qian Hong, Zhao Shu Qi. Rated voltage 0.6/1kV double co-extruded insulation Radiation cross-linked halogen-free low smoke flame retardant power cables

1 Scope

This standard specifies the terms and conditions of rated voltage 0.6/1kV double co-extruded insulation cross-linked halogen-free low smoke flame retardant, fire-resistant power cable Meaning, Classification and Marking, General Provisions, Requirements, Test Methods, Inspection, Marking, Packaging, Transport and Storage. This standard applies to industrial and civil buildings rated voltage 0.6/1kV double co-extruded insulation radiation cross-linked halogen-free low smoke flame retardant, fire-resistant electricity cable.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 1408.1-2006 Insulating material electrical strength test methods - Part 1. Test at power frequency (IEC 60243-1..1998, IDT) GB/T 1410-2006 Test methods for volume resistivity and surface resistivity of solid insulating materials (IEC 60093. 1980, IDT) GB/T 2406.2-2009 Plastics - Determination of combustion behavior by oxygen index method - Part 2. Room temperature test (ISO 4589-2..1996, IDT) GB/T 2900.10 Electrotechnical terminology cables (IEC 60050-461..2008, IDT) GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of electric cables and cables - Part 11. Common test methods Method --- thickness and shape measurement --- mechanical properties test (IEC 60811-1-1..2001, IDT) GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of electric cables and cables - Part 12. Common test methods Method --- thermal aging test method (IEC 60811-1-2. 1985, IDT) GB/T 2951.13-2008 Common test methods for insulating and sheathing materials of electric cables and cables - Part 13. General test methods Method --- Determination of density --- Water absorption test --- Shrinkage test (IEC 60811-1-3..2001, IDT) GB/T 2951.14-2008 Common test methods for insulating and sheathing materials of electric cables and cables - Part 14. Common test methods Method --- low temperature test (IEC 60811-1-4. 1985, IDT) GB/T 2951.21-2008 Common test methods for insulating and sheathing materials of electric cables and cables - Part 21. Elastomer mixtures Test methods --- ozone-resistant test --- thermal elongation test --- immersion mineral oil test (IEC 60811-2-1..2001, IDT) GB/T 2951.31-2008 Common test methods for insulating and sheathing materials of electric cables and cables - Part 31. Polyvinyl chloride compounds Specific test methods --- High temperature pressure test --- Cracking resistance test (IEC 60811-3-1. 1985, IDT) GB/T 3048.4-2007 wire and cable electrical performance test methods - Part 4. Conductors DC resistance test GB/T 3048.8 wire and cable electrical performance test methods Part 8. AC voltage test GB/T 3048.9 wire and cable electrical performance test methods - Part 9. insulated wire spark test GB/T 3048.10 wire and cable electrical performance test methods - Part 10. Extrusion sheath spark test GB/T 3082 armored cable with hot-dip galvanized or hot dip galvanized -5% aluminum - mixed rare earth alloy coating low-carbon steel wire GB/T 3956-2008 Cable conductor (IEC 60228..2004, IDT) Bare wires - Test methods - Part 2. Measurement of dimensions GB/T 4909.2-2009 GB/T 4909.3 Bare wire test methods - Part 3. Rally test GB/T 4909.5 Bare wire test methods - Part 5. Bending test --- repeated bending GB/T 5013.2-2008 Rubber insulated cables of rated voltages up to and including 450/750 V - Part 2. Test methods (IEC

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JG/T 442-2014_English be delivered?

Answer: Upon your order, we will start to translate JG/T 442-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JG/T 442-2014_English with my colleagues?

Answer: Yes. The purchased PDF of JG/T 442-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.