US$469.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JG/T 440-2014: Test method for shading performance of windows and doors Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| JG/T 440-2014 | English | 469 |
Add to Cart
|
3 days [Need to translate]
|
Test method for shading performance of windows and doors
| Valid |
JG/T 440-2014
|
PDF similar to JG/T 440-2014
Basic data | Standard ID | JG/T 440-2014 (JG/T440-2014) | | Description (Translated English) | Test method for shading performance of windows and doors | | Sector / Industry | Building & Construction Industry Standard (Recommended) | | Classification of Chinese Standard | Q70 | | Classification of International Standard | 91.060 | | Word Count Estimation | 18,128 | | Date of Issue | 6/30/2014 | | Date of Implementation | 12/1/2014 | | Quoted Standard | GB/T 5823; GB/T 13475; JGJ/T 151-2008; JG/T 356-2012; JG/T 399; ISO 9050-2003 | | Regulation (derived from) | Housing and Urban-Rural Development Bulletin No. 463 | | Issuing agency(ies) | Ministry of Housing and Urban-Rural Development of the People's Republic of China | | Summary | This standard specifies the doors and windows shading performance test methods and definitions of terminology, symbols, general provisions, optical properties, artificial light method and test report. This standard applies to windows and doors, including |
JG/T 440-2014: Test method for shading performance of windows and doors---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test method for shading performance of windows and doors
ICS 91.060
Q70/79
People's Republic of China building industry standards
Building windows and doors shading performance testing methods
Posted on June 30,.2014
2014-12-01 implementation
Ministry of Housing and Urban-Rural Development, People's Republic of China released
Directory
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions, symbol 1
4 General Provisions 3
5 optical performance method 3
6 artificial light source method 8
7 test report 11
Appendix A (Normative) Calibration of heat flow coefficient 13
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard proposed by the Ministry of Housing and Urban Standard and Design Institute.
This standard by the Housing and Urban-Rural Construction Products and Components Standardization Technical Committee.
This standard is drafted by. Guangdong Academy of Building Research, China Academy of Building Research
Participated in the drafting of this standard. Beijing Institute of Building Science and Technology Co., Ltd., China Building Materials Inspection and Certification Group Co., Ltd.,
Fujian Academy of Building Research, Shanghai Academy of Building Research (Group) Co., Ltd., China CSG Group Co., Ltd., Wei Kekai
(China) Investment Co., Ltd. AP R & D center.
The main drafters of this standard. Yang Shichao, Wang Hongtao, Ma Yang, Ren Jing, Shi Xinyong, Xu Wuyi, Huang Xiaodong, Xu Qin, Yue Peng, Yang Huaqiu,
Liu Huitao, Jackie Chan, Court De Jun.
Building windows and doors shading performance testing methods
1 Scope
This standard specifies the terms and definitions, inspection methods, symbols, general provisions, optical performance method, artificial light source method
And test report.
This standard applies to the construction of doors and windows, including the addition of a parallel with the door or window shade parallel to the detection of the sun shade coefficient.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 5823 building doors and windows terminology
GB/T 13475 Determination of heat transfer steady - state properties of heat transfer Calibration and protection of hot box method
Thermal calculation procedures for building windows and doors glass curtain wall
JG/T 356-2012 Building Sunshades thermal comfort, visual comfort performance testing methods
JG/T 399 building shade product terminology standards
ISO 9050..2003 Building Glass - Visible Light Transmittance, Direct Sunlight Transmission, Total Solar Transmittance, Ultraviolet Light Transmission, and
Determination of glass panes parameters (Glassinbuilding-Determinationoflighttransmittance, solardirecttrans-
mittance, total solar energy transmittance, ultraviolet transmittance and related glazing factors)
3 Terms and definitions, symbols
GB/T 5823, JG/T 399, JG J/T 151-2008 as defined by the following terms and definitions, the symbols apply to this document.
3.1 Terms and definitions
3.1.1
Window shading coefficient shadingcoefficientofwindowsanddoors
Under given conditions, the total solar transmittance of windows and doors, windows and doors with additional sun-shading devices, the standard glass with the same area under the same conditions
(3mm thick transparent glass) the ratio of the total solar transmittance.
3.1.2
The sun has heat solarheatgain; SHG
The amount of solar energy entering the interior through building doors and windows, including solar radiation directly transmitted through, and solar radiation by the glass, the door
Window components and then absorbed by radiation, conduction or convection way into the indoor heat of the two parts.
3.1.3
Solar irradiance solarirradiance
Radiation distributed in the solar spectrum as the radiation source, the irradiance formed on a certain surface.
3.1.4
Solar thermal coefficient solarheatgaincoefficient; SHGC
Total solar transmittance totalsolarenergytransmittance
The ratio between solar heat gain and solar radiation projected onto doors and windows.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JG/T 440-2014_English be delivered?Answer: Upon your order, we will start to translate JG/T 440-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JG/T 440-2014_English with my colleagues?Answer: Yes. The purchased PDF of JG/T 440-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|