US$599.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JG/T 396-2012: Non-load bearing fiber-reinforced-cement sheet for exterior wall Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| JG/T 396-2012 | English | 599 |
Add to Cart
|
4 days [Need to translate]
|
Non-load bearing fiber-reinforced-cement sheet for exterior wall
| Valid |
JG/T 396-2012
|
PDF similar to JG/T 396-2012
Basic data | Standard ID | JG/T 396-2012 (JG/T396-2012) | | Description (Translated English) | Non-load bearing fiber-reinforced-cement sheet for exterior wall | | Sector / Industry | Building & Construction Industry Standard (Recommended) | | Classification of Chinese Standard | Q15 | | Classification of International Standard | 91.060.10 | | Word Count Estimation | 23,293 | | Quoted Standard | GB/T 1720; GB/T 1732; GB/T 1733; GB/T 1771; GB/T 5464; GB 6566; GB/T 6739; GB/T 7019; GB/T 8170; GB 8624-2012; GB/T 9266; GB 9274; GB/T 9286; GB/T 9754; GB/T 9780; GB/T 10294; GB/T 15608-2006; GB/T 17748; JC/T 564.2; HG/T 3792; HG/T 4104 | | Adopted Standard | ISO 8336-2009, MOD | | Regulation (derived from) | Bulletin of the Ministry of Housing and Urban 1522; industry standard filing Notice 2013 No. 2 (No. 158 overall) | | Issuing agency(ies) | Ministry of Housing and Urban-Rural Development of the People's Republic of China | | Summary | This standard specifies a non-load-bearing exterior fiber reinforced cement board (hereinafter referred to as fiber-reinforced cement board) terms and definitions, classification, specifications and markings, general requirements, requirements, test metho |
JG/T 396-2012: Non-load bearing fiber-reinforced-cement sheet for exterior wall---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Non-load bearing fiber-reinforced-cement sheet for exterior wall
ICS 91.060.10
Q15
People's Republic of China building industry standards
Exterior wall with non-load-bearing fiber reinforced cement board
Posted on.2012-11-01
2013-01-01 implementation
Ministry of Housing and Urban-Rural Development, People's Republic of China released
Directory
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 categories, specifications and markings 2
5 General Requirements 3
6 Requirements 3
7 Test Method 5
8 Inspection rules 8
9 signs and certificates 9
10 Transport, Packaging and Storage 10
Appendix A (Normative) Coating board coating quality requirements and test standards 11
Appendix B (Informative) Exterior wall with non-load-bearing low-density fiber reinforced cement board 12
Appendix C (Normative) Durability test method 15
Appendix D (Normative) Humidity Deformation Test Method 19
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard uses the redrafted law to amend the use of ISO 8336..2009 "Fiber cement slab - Product Specifications and Test Methods." With ISO
8336. The main technical differences in.2009 are as follows.
--- Increased diagonal size allowable deviation, surface roughness, apparent density, water absorption and coating quality requirements.
--- Increased humidity deformation, clearly less than or equal to 0.07%.
--- Modify the durability index, unified in the ISO 8336..2009 frost resistance of 100 times, modified to climatic zones. cold areas
100 times, 75 times in the cold area, 50 in the hot summer and cold winter area and 25 in the hot summer and warm winter area.
--- Modify the physical and mechanical properties of the coating test state, in the ISO 8336..2009 plate physical and mechanical properties
Can be coated with the test, but the test results should be marked with a coating test; combined with the quality of the domestic coating, clearly amended as follows.
Fiber-reinforced concrete slabs that are tested for their physical properties and mechanical properties shall not be treated with water repellent or painted.
--- Remove the full state of flexural strength greater than or equal to 4MPa lower mechanical performance level.
This standard Appendix B using the redrafted method is not equivalent to the use of JISA5422..2008 "fiber reinforced cement wall panels."
This standard proposed by the Ministry of Housing and Urban Standard and Design Institute.
This standard by the Housing and Urban-Rural Construction Products and Components Standardization Technical Committee.
This standard is drafted by. China Building Standard Design Institute.
Participated in the drafting of this standard. China Academy of Building Research, Guangzhou E Tenet Construction Systems Co., Ltd., Shenzhen Haichuan Industrial Stock
Co., Ltd., Ji-Hua decorative fiber cement wall panels (Jiaxing) Co., Ltd., Jinqiang (Fujian) Building Materials Technology Co., Ltd., Zhejiang Hailong
New Building Materials Co., Ltd., Shanghai Weida Energy Technology Co., Ltd., Jiangsu double-composite Materials Co., Ltd., Yichun Jinte Building Materials Industry
Co., Ltd., Ningbo Yihe Green Sheet Co., Ltd., Sichuan Aofeixi Construction Engineering Co., Ltd., Shandong Wall Crown Building Materials Technology Co., Ltd.,
Zhejiang Ruiming Decoration Materials Co., Ltd., Jiangsu Germany a new building materials Technology Co., Ltd..
The main drafters of this standard. Cao Bin, Lu Xing, Wang Jingxian, Zhang Jiayan, Guo Peijia, Zhao Xinping, Chen Yu, Chen Yingling, Xu Dingfeng,
Jiang Jianxing, Liu Jianyong, Lu Changjiang, Tang Jianming, Dong Xianlin, Wang Zhimin, Tan Jianxin, Song Beizheng.
Exterior wall with non-load-bearing fiber reinforced cement board
1 Scope
This standard specifies the external wall with non-load-bearing fiber reinforced cement board (hereinafter referred to as fiber reinforced cement board) terms and definitions, classification, specifications
And marking, general requirements, requirements, test methods, inspection rules, signs and certificates, transport, packaging and storage.
This standard applies to non-load-bearing reinforced concrete wall cladding, panels and linings.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 1720 Determination of film adhesion
GB/T 1732 film impact resistance assay
GB/T 1733 film water resistance test
GB/T 1771 Paints and varnishes - Determination of neutral salt spray performance (GB/T 1771-2007, ISO 7253..1996, IDT)
GB/T 5464 flammability of building materials test methods
GB 6566 Building materials radionuclide limits
GB/T 6739 Paints and varnishes - Determination of film hardness by the pencil method (GB/T 6739-2006, ISO 15184..1998, IDT)
Test method for GB/T 7019 fiber cement products
GB/T 8170 rounded repair rules and limit values of the representation and judgment
Classification of combustion properties of building materials and products
Coatings GB/T 9266 Determination of washing resistance
Determination of GB 9274 Paints and varnishes resistant to liquid media (GB 9274-1988, eqvISO 2812. 1974)
GB/T 9286 Paints and varnishes - Cross-hatch test (GB/T 9286-1998, eqvISO 2409..1992)
GB/T 9754 Paints and varnishes - Determination of the specular gloss at 20 °, 60 ° and 85 ° of metallic paint-free paint films
(GB/T 9754-2007, ISO 2813..1994, IDT)
GB/T 9780 architectural coatings coatings stain resistance test methods
GB/T 10294 Insulating materials - Determination of steady - state thermal resistance and related characteristics
GB/T 15608-2006 China color system
GB/T 17748 building walls with aluminum-plastic composite panels
JC/T 564.2 Fiber reinforced calcium silicate board - Part 2. Chrysotile calcium silicate board
HG/T 3792 cross-linked fluororesin coating
HG/T 4104 building water-based fluorine paint
3 Terms and definitions
The following terms and definitions apply to this document.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JG/T 396-2012_English be delivered?Answer: Upon your order, we will start to translate JG/T 396-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JG/T 396-2012_English with my colleagues?Answer: Yes. The purchased PDF of JG/T 396-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|