US$259.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. HYT120-2008: Electrodeionization stacks(modules) Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| HY/T 120-2008 | English | 259 |
Add to Cart
|
3 days [Need to translate]
|
Electrodeionization stacks(modules)
| Valid |
HY/T 120-2008
|
PDF similar to HYT120-2008
Basic data | Standard ID | HY/T 120-2008 (HY/T120-2008) | | Description (Translated English) | Electrodeionization stacks(modules) | | Sector / Industry | Marine Industry Standard (Recommended) | | Classification of Chinese Standard | J77 | | Classification of International Standard | 07.060; 23.100.60 | | Word Count Estimation | 10,153 | | Date of Issue | 7/28/2008 | | Date of Implementation | 10/1/2008 | | Quoted Standard | GB 13659; GB 13660; GB/T 11446.4; GB/T 11446.8; GB/T 191; GB 9706.1-2007; HY/T 034.2-1994; HY/T 034.3-1994, | | Issuing agency(ies) | State Oceanic Administration | | Summary | This standard provides electricity to the membrane stack (referred to as "membrane reactor") and electrodeionization components (referred to as "Components") classification and models, requirements, test methods, inspection rules, marking, packaging, transportation, and storage. This standard applies to the production of pure water, high pure water membrane reactor (components) of the design, manufacture. |
HYT120-2008: Electrodeionization stacks(modules)---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Electrodeionization stacks(modules)
ICS 07.060; 23.100.60
J77
People's Republic of China Marine Industry Standard
HY/T 120-2008
Electrodeionization membrane stack (component)
2008-07-28 released
Implementation of.2008-10-01
Issued by the State Oceanic Administration
Foreword
Appendix A of this standard is a normative appendix.
This standard was proposed by China Membrane Industry Association.
This standard is under the jurisdiction of the National Marine Standardization Technical Committee (SAC/TC283).
Drafting organizations of this standard. Institute of Medical Equipment, Chinese Academy of Military Medical Sciences, Zhejiang Occident Environmental Engineering Co., Ltd.,
Beijing Grant Membrane Separation Equipment Co., Ltd., Shanghai Etiti Hengtong Advanced Water Treatment Co., Ltd., Zhejiang Dongda Water Co., Ltd., Zhejiang
Qianqiu Environmental Water Treatment Co., Ltd.
The main drafters of this standard. Liu Hongbin, Comrade Zhiming, Meng Guangzhen, Chen Wei, Wu Yier, Tan Shibin, Su Jianyong, Ma Jun.
HY/T 120-2008
Electrodeionization membrane stack (component)
1 scope
This standard specifies the classification, models, requirements and tests of electrodeionization membrane stacks (referred to as "membrane stacks") and electrodeionization modules (referred to as "modules")
Methods, inspection rules, marking, packaging, transportation and storage, etc.
This standard applies to the design and manufacture of membrane stacks (modules) for the production of pure water and high-purity water.
2 Normative references
The clauses in the following documents become clauses of this standard after being quoted. For dated reference documents, all subsequent
Amendments (not including errata content) or revisions do not apply to this standard. However, all parties that have reached an agreement based on this standard are encouraged to study
Is the latest version of these files available? For undated references, the latest version is applicable to this standard.
GB/T 191 Graphical signs for packaging, storage and transportation
GB 9706.1-2007 Medical electrical equipment Part 1.General requirements for safety
GB/T 11446.4 Test method for electrical resistivity of electronic grade water
GB/T 11446.8 Test method for total organic carbon in electronic grade water
GB 13659001×7 Strong acid styrene cation exchange resin
GB 13660.201×7 strong basic styrene anion exchange resin
HY/T 034.2-1994 Electrodialysis technology heterogeneous ion exchange membrane
HY/T 034.3-1994 Electrodialysis technology electrodialysis device
3 Terms and definitions
The following terms and definitions apply to this standard.
3.1
Continuous deionization continouusdeionizatin, CDI (abbreviation)
Taking the potential difference as the driving force, using the anion and cation exchange membrane to selectively permeate the anion and cation in the aqueous solution, and the ion of the ion exchanger
Exchange and transfer, as well as the regeneration of ion exchangers by the H+ and OH- generated by hydrolysis under the conditions of concentration polarization, make the aqueous solution
The separation process in which the ions in the membrane are continuously transferred from one side of the membrane to the other side.
3.2
The anion and cation exchange membranes, the partitions and electrodes of the fresh and concentrated water chambers are arranged according to certain rules to form a fresh water chamber, a concentrated water chamber and an electrode chamber.
The water chamber is filled with ion exchanger, or both the light and concentrated water chambers are filled with ion exchanger, and the electrodeionization is clamped by clamping parts in the form of a plate and frame
unit.
3.3
The anion and cation exchange membranes and the partitions and electrodes of the fresh and concentrated water chambers are arranged according to certain rules to form a fresh water chamber, a concentrated water chamber and an electrode chamber.
The water chamber is filled with ion exchangers, or both the light and concentrated water chambers are filled with ion exchangers, and they are filled into cylindrical airtight containers in the form of cylinders.
The electrodeionization unit.
HY/T 120-2008
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of HYT120-2008_English be delivered?Answer: Upon your order, we will start to translate HYT120-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of HYT120-2008_English with my colleagues?Answer: Yes. The purchased PDF of HYT120-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|