US$329.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. HYT0187.5-2021: (Design Specification for Seawater Circulating Cooling System - Part 5: Circulating Water Field) Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| HY/T 0187.5-2021 | English | 329 |
Add to Cart
|
3 days [Need to translate]
|
(Design Specification for Seawater Circulating Cooling System - Part 5: Circulating Water Field)
| Valid |
HY/T 0187.5-2021
|
PDF similar to HYT0187.5-2021
Basic data | Standard ID | HY/T 0187.5-2021 (HY/T0187.5-2021) | | Description (Translated English) | (Design Specification for Seawater Circulating Cooling System - Part 5: Circulating Water Field) | | Sector / Industry | Marine Industry Standard (Recommended) | | Classification of Chinese Standard | A45 | | Word Count Estimation | 14,153 | | Issuing agency(ies) | Ministry of Natural Resources of the People's Republic of China |
HYT0187.5-2021: (Design Specification for Seawater Circulating Cooling System - Part 5: Circulating Water Field) ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Design Specification for Seawater Circulating Cooling System Part 5.Circulating Water Field)
ICS 07.060;91.140
CCSA45
People's Republic of China Marine Industry Standard
Design code for seawater circulating cooling system
Part 5.Circulating Water Fields
Published on 2021-02-09
2021-06-01 Implementation
Published by the Ministry of Natural Resources of the People's Republic of China
foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents"
drafted.
This document is part 5 of the Code for Design of Seawater Circulating Cooling Systems. "Code for Design of Seawater Circulating Cooling System" has been published
Lower part.
---HY/T 187.1 Code for Design of Seawater Circulating Cooling System Part 1.Technical Requirements for Water Intake;
---HY/T 187.2 Code for Design of Seawater Circulating Cooling System Part 2.Technical Requirements for Drainage;
---HY/T 240.3 Code for Design of Seawater Circulation Cooling System Part 3.Seawater Pretreatment;
---HY/T 187.4 Code for Design of Seawater Circulating Cooling System Part 4.Guidelines for Material Selection and Anticorrosion Design;
---HY/T 0187.5 Code for Design of Seawater Circulating Cooling System Part 5.Circulating Water Field.
This document is proposed by the Ministry of Natural Resources of the People's Republic of China.
This document is under the jurisdiction of the National Marine Standardization Technical Committee (SAC/TC283).
This document is drafted by. Tianjin Institute of Seawater Desalination and Comprehensive Utilization, Ministry of Natural Resources, Tianjin SDIC Jinneng Power Generation Co., Ltd., China Resources
Electric Power (Bohai New Area) Co., Ltd.
The main drafters of this document. Wang Yinzhong, Zhang Wenshuai, Yi Qingwen, Li Chunlei, Li Xue, Zhang Lianqiang, Yin Jianhua.
Introduction
In recent years, the seawater circulating cooling system can replace a large amount of fresh water, with less water intake and discharge, and less impact on the marine natural environment.
It has gained more and more engineering applications in my country. In order to standardize and guide the design of seawater circulating cooling system, make seawater circulating cooling system
The system meets the requirements of safety and reliability, advanced technology, economical rationality, convenient management, energy saving and environmental protection.
But the system design specification" series of industry standards.
In order to facilitate partition or step-by-step design, HY/T 0187 "Code for Design of Seawater Circulation Cooling System" is intended to consist of 5 parts.
--- Part 1.Technical requirements for water intake. The purpose is to standardize the design of seawater intake structures and the selection of related equipment.
--- Part 2.Technical requirements for drainage. The purpose is to standardize the comprehensive utilization, treatment and discharge design of seawater drainage.
--- Part 3.Seawater pretreatment. The purpose is to standardize the design of original seawater treatment structures and the selection of related equipment.
--- Part 4.Guidelines for material selection and anti-corrosion design. The purpose is to guide the materials and anti-corrosion measures used in the seawater circulating cooling system
selection.
--- Part 5.Circulating water field. The purpose is to standardize the layout of the circulating water field and the functional connection of buildings and structures in the field.
Different from the design of general fresh water circulating cooling system, because of the use of seawater, the design work of seawater circulating cooling system becomes more complicated.
Complex and burdensome. In order to facilitate the division and cooperation of designers and avoid the length of the standard, based on relatively independent and interrelated functional distinctions,
HY/T 0187 "Code for Design of Seawater Circulating Cooling System" is divided into 5 parts, and cooperates with the current GB/T 23248 "Seawater Circulating Cooling Water".
Processing Design Specifications are used.
Design code for seawater circulating cooling system
Part 5.Circulating Water Fields
1 Scope
This document specifies the technical requirements for the design of the circulating water field of the seawater circulating cooling system.
This document is applicable to the design of the circulating water field of the new, reconstructed or expanded seawater circulating cooling system in the electric power and chemical industries, and the design of the circulating water field of the seawater circulating cooling system
The design of the circulating water field of the seawater circulating cooling system can be implemented by reference.
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations
documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to
this document.
GB/T 3091 Welded steel pipes for low pressure fluid transportation
GB/T 5696 Prestressed Concrete Pipe
GB/T 12763.4 Marine Survey Specifications Part 4.Survey of Marine Chemical Elements
GB/T 16166 Sacrificial anode cathodic protection for seawater cooling water system in Binhai power plant
GB/T 17005 General Requirements for Impressed Current Cathodic Protection Systems for Coastal Facilities
GB 17378.4 Marine Monitoring Specification Part 4.Analysis of Seawater
GB/T 19685 Prestressed Concrete Cylinder Pipe
GB/T 23248 Design code for seawater circulating cooling water treatment
GB/T 33584 (all parts) seawater cooling water quality requirements and analysis and testing methods
GB/T 34550 (all parts) Performance evaluation method of seawater cooling water treatment chemicals
GB/T 50046 Code for anti-corrosion design of industrial buildings
GB/T 50102 Design Specification for Industrial Circulating Water Cooling
GB 50265 Design Specification for Pumping Station
GB 50489 General plan transportation design specification for chemical enterprises
DL/T 933 Cooling tower water spray packing, water eliminator, spray device performance test method
DL/T 5032 General drawing transportation design specification for thermal power plants
DL/T 5507 Basic data of hydraulic design of thermal power plant and its depth requirements
DL/T 5525 Cooling tower core components selection design guidelines
HY/T 187.1 Code for Design of Seawater Circulating Cooling System Part 1.Technical Requirements for Water Intake
HY/T 187.2 Code for Design of Seawater Circulating Cooling System Part 2.Technical Requirements for Drainage
HY/T 189 Technical requirements for carbon steel corrosion and scale inhibitor for seawater cooling water treatment
HY/T 191 Determination of iron in seawater cooling water
HY/T 240.3 Code for Design of Seawater Circulation Cooling System Part 3.Seawater Pretreatment
3 Terms and Definitions
The terms and definitions defined in HY/T 187.1 and the following terms and definitions apply to this document.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of HYT0187.5-2021_English be delivered?Answer: Upon your order, we will start to translate HYT0187.5-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of HYT0187.5-2021_English with my colleagues?Answer: Yes. The purchased PDF of HYT0187.5-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|