|
US$1359.00 · In stock Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. HJ 856-2017: Technical specification for application and issuance of pollutant permit -- glass industry -- flat glass Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| HJ 856-2017 | English | 1359 |
Add to Cart
|
7 days [Need to translate]
|
Technical specification for application and issuance of pollutant permit -- glass industry -- flat glass
| Valid |
HJ 856-2017
|
PDF similar to HJ 856-2017
Basic data | Standard ID | HJ 856-2017 (HJ856-2017) | | Description (Translated English) | Technical specification for application and issuance of pollutant permit -- glass industry -- flat glass | | Sector / Industry | Environmental Protection Industry Standard | | Classification of Chinese Standard | Z00 | | Word Count Estimation | 59,577 | | Issuing agency(ies) | Ministry of Ecology and Environment |
HJ 856-2017: Technical specification for application and issuance of pollutant permit -- glass industry -- flat glass ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical specification for application and issuance of pollutant permit -- glass industry -- flat glass
National Environmental Protection Standard of the People 's Republic of China
2017-09-12 released
2017-09-12 implementation
Ministry of Environmental Protection released
Directory
Preface .ii
1 Scope of application 1
2 normative reference document 1
3 terms and definitions
4 sewage unit basic situation to fill in the requirements
5 Determine the method of determining the discharge and the permissible emission limits
6 feasible technical requirements for pollution prevention and control
Self - monitoring management requirements
Requirements for the preparation of environmental management ledger and sewage permit
9 Actual emissions accounting method
10 Compliance Method
Appendix A (informative) Environmental Management Accounting Record Reference Table
APPENDIX B (INFORMATION APPENDIX) DISPOSAL PERFORMANCE REPORT OF THE DRAINAGE PORT
Foreword
In order to implement the Environmental Protection Law of the People's Republic of China, the Law of the People's Republic of China on the Prevention and Control of Atmospheric Pollution,
People's Republic of China Water Pollution Control Law "and other laws and regulations and the" General Office of the State Council on the issuance of control of pollutant discharge permit system
(National Office issued 〔2016〕 81), improve the sewage permit technical support system, guidance and norms flat
Glass industry sewage unit sewage permit application and issuance work, the development of this standard.
This standard specifies the basic requirements for the application and issuance of the sewage permit for the flat glass industry.
Determination of emission limits, actual emissions accounting, compliance determination methods and self-monitoring, environmental management accounts and sewage permits
License implementation report and other environmental management requirements, put forward the flat glass industry pollution control feasible technical requirements.
Issued by the issuing authority issued a permit, the laws and regulations are clearly prohibited in the construction area, belonging to the state or
Where it is expressly provided that the flat glass industry discharge unit or the production plant that has been eliminated or banned, it shall not be allowed to issue sewage
Can be certified.
Appendix A and Appendix B of this standard are informative.
This standard is the first release.
This standard is organized by the Planning and Finance Department of the Ministry of Environmental Protection and the Ministry of Environmental Protection.
The main drafting unit of this standard. Beijing Central Branch Environmental Engineering Design Institute, Hebei University of Science and Technology, Henglian HNA (Beijing)
Management Consulting Co., Ltd., China Architectural Glass and Industrial Glass Association, Environmental Protection Department Environmental Engineering Assessment Center, Hebei Province
Environmental Science Society.
The environmental protection department of this standard approved on September 12,.2017.
This standard has been implemented since September 12,.2017.
This standard is explained by the Ministry of Environmental Protection.
- 1 -
Sewage permit application and issuance of technical specifications Glass industry - Flat glass
1 Scope of application
This standard specifies the basic requirements for the application and issuance of the sewage permit for the flat glass industry.
Determination of emission limits, actual emissions accounting, compliance determination methods and self-monitoring, environmental management accounts and sewage permits
License implementation report and other environmental management requirements, put forward the flat glass industry pollution control feasible technical requirements.
This standard applies to guide the implementation of GB 26453 flat glass industry sewage unit to fill out the "sewage permit application form"
And online to fill in the relevant application information, apply to guide the issuance of the authorities to determine the flat glass industry sewage unit sewage permit
Permission request.
This standard applies to the flat glass industry sewage unit emissions of air pollutants and water pollutants permit management.
This standard does not provide for the provisions of the discharge of industrial waste water, exhaust gas or the provisions of the state of toxic and harmful air pollutants flat glass
In addition, the other pollutant production facilities and discharge ports shall be referred to in accordance with the General Rules for the Application of Technical Standards for Discharge Permits
Row.
2 normative reference documents
The contents of this standard refer to the following documents or the terms of the following. Those who do not note the date of the reference file, the effective version of the appropriate
For this standard.
Comprehensive Emission Standard for Wastewater
Standard for Hazardous Waste Storage Pollution Control
GB 26453 Standard for Emission of Air Pollutants from Flat Glass Industry
Determination of particulate matter and sampling method of gaseous pollutants in exhaust gas of fixed pollution sources GB/T 16157
GB/T 31962 Sewage Discharge Standard for Urban Sewerage
Technical Guidance for Water Quality Sampling
Technical specification for water quality sampling scheme design of HJ 495
General guidelines for self - monitoring of sewage disposal units
Technical Guidelines for Unorganized Emissions Monitoring of Air Pollutants
HJ/T 75 fixed pollution sources flue gas discharge continuous monitoring technical specifications (Trial)
HJ/T 76 fixed pollution source flue gas emissions continuous monitoring system technical requirements and testing methods (Trial)
Technical specification for surface water and wastewater monitoring
Technical specification for manual monitoring of ambient air quality
HJ/T 353 water pollution source on-line monitoring system installation technical specifications (Trial)
HJ/T 354 Water Pollution Source Online Monitoring System Acceptance Technical Specification (Trial)
HJ/T 355 water pollution source on-line monitoring system operation and assessment of technical specifications (Trial)
HJ/T 356 Water pollution source online monitoring system data validity judgment technical specification (Trial)
HJ/T 373 fixed pollution source monitoring quality assurance and quality control technical specifications (Trial)
Technical specification for HJ/T 397 fixed source exhaust gas monitoring
General rules for application and issuance of emission permits
Discharge Unit Self-Monitoring Technical Guide Flat glass industry
Environmental Management Account and Discharge Permit Implementation Report Technical Specification (Trial)
"Fixed pollution source pollution permit classification management directory"
"Standardization of sewage outfall technical requirements (Trial)" (State Environmental Protection Administration Environmental Protection [1996] No. 470)
"Pollution source automatic monitoring facilities operation and management approach" (Central [2008] No. 6)
"Notice on the Implementation of Special Limitation of Emissions of Air Pollutants" (Announcement No. 14 of.2013)
Standard Specification for Flat Glass Industry (2014) Announcement (Announcement of Industrial and Information Department of the People's Republic of China
90th of.2014)
"Notice on the Issuance of the Interim Provisions on the Administration of Pollution Permit" (Ring Water [2016] No. 186)
"On the implementation of thermal power, paper industry and the Beijing-Tianjin-Hebei pilot cities elevated source sewage permit management notice" (ring
Water body [2016] 189)
Notice on Strengthening the Automatic Monitoring of Elevated Source Pollutants in Beijing, Tianjin and Hebei Provinces
number)
"Notice on the publication of the" High Pollutant Fuel Catalog "(No. 2 [2017]
3 terms and definitions
The following terms and definitions apply to this standard.
3.1 flat glass industry flat glass industry
Refers to the use of float, rolling and other processes to create flat glass industry.
3.2 flat glass industry sewage unit flat glass industry pollutant emission unit
Refers to the flat glass industry containing the production process of sewage units.
3.3 Permissible emission limits
Refers to the maximum discharge concentration and emissions of pollutants discharged by the pollutant discharge unit as specified in the pollutant discharge permit.
4 sewage unit basic situation to fill the requirements
4.1 Basic principles
Flat glass industry sewage unit should be in accordance with the requirements of this standard, in the sewage permit management information platform to declare the system
The corresponding information form in the "Sewage Permit Application Form". Fill in the local environmental protection supervisor that is not included in the system drop-down menu
Departments have required to fill in or flat glass industry sewage units that need to fill in the report, you can add content.
Provincial environmental protection departments in accordance with environmental quality improvement needs to increase the management requirements, should be filled into the sewage permit management letter
Interest rate platform declaration system "the right to endorse the local environmental protection authorities to increase the management content" column.
Flat glass industry sewage unit to fill in the application information, should assess the status of pollutant emissions and environmental management, the status quo
Environmental issues put forward rectification measures, and fill in the sewage permit management information platform reporting system "corrective measures" column.
Flat glass industry sewage unit should be in accordance with the actual situation to fill in the basic situation, the application of the authenticity of the material, legal and integrity.
4.2 Sewage Unit Basic Information
The basic information of the sewage unit should be filled in the name of the unit, postal code, whether the production, production date, production and operation sites
Heart length, production and management center center latitude, whether the location is a key area, whether the environmental impact assessment documents approved
And the number (record number), whether the local government on the violation of the project identification or filing documents and the number, whether the main pollution
(T/a), total sulfur dioxide (t/a), nitrogen oxides
(T/a), total chemical oxygen demand (t/a), total ammonia nitrogen (t/a), total other pollutants
Standard (if any).
4.3 Major products and production capacity
4.3.1 The main production unit, the main process, production facilities and facilities parameters
Flat glass industry sewage unit The main production unit, the main process, production facilities and facilities parameters reported in Table 1.
Table 1 Tablet glass industry sewage unit Main production units, the main process, production facilities and facilities parameters table
The main production unit of the main process production facilities and facilities parameters
Float glass production line
Raw material crushing system
Rough handling capacity
Fine crushing capacity
Screening capacity
Bucket elevator delivery volume
Belt conveyor delivery
other/
Stocking and storage systems
Bucket elevator delivery volume
Belt conveyor delivery
Screening capacity
Homogeneous equipment handling capacity
other/
Ingredients system
Mixer total volume
Bucket elevator delivery volume
Belt conveyor delivery
Kiln head silo storage
other/
Broken glass system
Broken glass crusher
Belt conveyor delivery
other/
Melting process
Feeding machine daily feeding volume
Melting amount of glass melting furnace
other/
Floating glass production line forming annealing process
Tin trough drawing speed
Online coating equipment coating type
Annealing furnace annealing ability
other/
- 4 -
Continued
The main production unit of the main process production facilities and facilities parameters
Float glass production line cutting and packing process
Annealing kiln roller turning equipment speed
Crosscutting machine cutting length range
The amount of broken crusher
other/
Calendering glass production line
Raw material crushing system
Rough handling capacity
Fine crushing capacity
Screening capacity
Bucket elevator delivery volume
Belt conveyor delivery
other/
Stocking and storage systems
Bucket elevator delivery volume
Belt conveyor delivery
Screening capacity
Homogeneous equipment handling capacity
other/
Ingredients system
Mixer total volume
Bucket elevator delivery volume
Belt conveyor delivery
Kiln head silo storage
other/
Broken glass system
Broken glass crusher
Belt conveyor delivery
other/
Melting process
Feeding machine daily feeding volume
Melting amount of glass melting furnace
other/
Forming annealing process
Calendering machine speed range
Annealing furnace annealing ability
other/
Cut the packing process
Annealing kiln roller turning equipment speed
Crosscutting machine cutting length range
The amount of broken crusher
other/
Fuel supply unit
Fuel System
Storage capacity of oil storage facilities
other/
Gas system
Natural gas storage tank volume
Coke oven gas tank volume
other/
Coal gas system
Coal storage
Coal processing, screening equipment handling capacity
Coal on coal
- 5 -
Continued
The main production unit of the main process production facilities and facilities parameters
Fuel supply unit
Coal gas system
Gas production furnace gas production
other/
Fuel oil coke system
Petroleum coke (powder) library reserves
Broken equipment broken pieces
Grinding equipment processing capacity
Screening equipment handling capacity
Conveying equipment
other/
Common unit
Waste heat boiler and power generation system
Waste boiler efficiency
Rated power of steam turbine
Generator output power
other/
Softened water preparation system
Multi-media filter device flow
other/
Nitrogen and hydrogen protection gas preparation system
Fractionation tower
Ammonia decomposition capacity of ammonia decomposition furnace
Electrolysis tank hydrogen production
other/
Water supply and circulating water cooling system
Cooling tower flow
other/
Liquid ammonia/ammonia storage system
Liquid ammonia tank volume
Ammonia tank volume
other/
auxiliary system
Ash library area
Ash field area
Gypsum warehouse covers an area
Desulphurization by - product warehouse area
other/
4.3.2 Production facility number
Flat glass industry sewage unit to fill the internal production facilities number, if the flat glass industry sewage unit without internal production set
Construction number, according to "on the implementation of thermal power, paper industry and the Beijing-Tianjin-Hebei pilot cities elevated source sewage permit management
(Water and air) coding rules (for trial) "in Annex 4 of the Notices.
4.3.3 Product name
Divided into float glass, calendered glass.
4.3.4 Production capacity and unit of measurement
Production capacity as the main product design capacity, not including national or local government to be eliminated or banned capacity. Capacity meter
The amount of units for the million t/a.
- 6 -
4.3.5 Design annual production time
According to environmental impact assessment documents and approval or local government on the violation of the project identified or filing documents in the annual production time
fill in.
4.3.6 other
Flat glass industry sewage unit if necessary to explain the contents can be filled.
4.4 Main raw and auxiliary materials and fuels
4.4.1 raw and auxiliary materials and fuel types
Raw materials include silica sand, feldspar, dolomite, limestone, soda ash, broken glass, others.
The types of excipients include the addition of chemicals in the process and the addition of chemicals to waste gas and waste water treatment
Such as clarifying agents, fluxes, oxidizing agents, reducing agents, coloring agents, bleaching agents, opacifying agents, ammonia water, liquid ammonia, lime,
Limestone, caustic soda, others.
Fuel types include natural gas, coke oven gas, furnace gas, heavy oil, coal tar, petroleum coke, coal, others.
4.4.2 Design Year Use and Unit of Measure
Design annual use for the production capacity to match the raw and auxiliary materials and fuel annual use. Units of measurement are million t/a or million
m3/a.
4.4.3 raw materials sulfur elements, toxic and harmful ingredients and accounting for
Flat glass industry sewage unit should fill the main raw and auxiliary materials of sulfur proportion, according to the design value or the actual value of the previous year
Fill in. Toxic and harmful ingredients and the proportion of the actual situation reported.
4.4.4 fuel ash, sulfur, volatile and calorific value
The use of coal-fired flat glass industry sewage units need to fill the coal ash, sulfur, volatile and calorific value, the use of natural
Gas, coke oven gas, heavy oil, coal tar and petroleum coke flat glass industry sewage units need to fill in sulfur and calorific value. Use coal
Tar, heavy oil, petroleum coke flat glass industry sewage unit should also be based on the characteristics of the fuel, fill in total mercury, total cadmium, total chromium,
Total arsenic, total lead, total nickel, total zinc and other heavy metal components and accounting for. Can be calculated according to the design value or the actual value of the previous year.
4.4.5 other
Flat glass industry sewage unit if necessary to explain the contents can be filled.
4.5 production of sewage links, pollutants and pollution control facilities
4.5.1 General principles
Waste gas production and sewage pollution, pollution and pollution control facilities, including the corresponding part of the pollution, pollutants, emissions (with
Organization, no organization), pollution control facilities, whether feasible technology, organized discharge port number,
Requirements, discharge type.
Wastewater production and sewage pollution, pollution and pollution control facilities, including waste water category, the type of pollutants, emissions, emissions
Rules, pollution control facilities, whether feasible technology, discharge port number, discharge port settings are in line with the requirements,
type.
- 7 -
4.5.2 Exhaust gas
4.5.2.1 Waste gas pollution sources, pollutant types, emission forms and pollution control facilities
Flat glass industry sewage unit waste gas pollution links, pollutants, emissions and pollution control facilities to fill in the content
See Table 2. Flat glass industry sewage unit pollutants according to GB 26453 to determine, there are local emission standards,
In accordance with local emission standards. For the use of heavy oil, coal tar, petroleum coke flat glass industry sewage units should also be root
According to the actual discharge of sewage units to consider mercury, cadmium, chromium, arsenic, lead, nickel, zinc and other heavy metal pollutants.
- 8 -
Table 2 Flat glass industry sewage unit waste gas production and pollution aspects, the type of pollutants, emissions and pollution control facilities list
produce
unit
Production facilities Waste gas - Proof of pollutants in the form of pollutants
Pollution control facilities
Whether the name and process of pollution control facilities are viable
Float
glass
produce
Rough broken machine, fine broken machine,
Siege, bucket mention
Elevator, belt conveyor
Machine, other
Broken gas, sieved
Exhaust, transport emissions,
Other particles
Organized
Electrostatic precipitator (indicating the number of electric field, such as three electric field, four electric field, etc.), bag filter
(Specify the type of filter), electronic bag dust collector (with electrostatic precipitator and bag dust
Equipment requirements, indicating the number of electric field and filter type), cyclone dust collector, filter cartridge,
other
□ Yes
□ No
Such as the use does not belong to "6 pollution control
Viable technical requirements "in the technology,
Should provide relevant supporting materials
Raw material crushing system None
Organization of waste gas
Unorganized
In the crushing, screening, transportation and other stages of closed operation, in the reproduced and the next note and other dust production
Point to set up local or integral gas collection system and purification treatment device, others
Ibid
Bucket elevator, belt
Type conveyor, sieving
Machine, other
Delivery of exhaust gas
Exhaust gas, feed waste gas,
other
particulates
Organized
Electrostatic precipitator (indicating the number of electric field, such as three electric field, four electric field, etc.), bag filter
(Specify the type of filter), electronic bag dust collector (with electrostatic precipitator and bag dust
Equipment requirements, indicating the number of electric field and filter type), cyclone dust collector, filter cartridge,
other
Ibid
Stocking and storage systems
No tissue exhaust
Unorganized
In the screening, transportation and other stages of closed operation, homogenization of siliceous materials in the closed homogenization of the library
In the reproduction and unloading points and other production point on the establishment of local or integrated gas collection system
And the purification treatment device, in the easy to produce dust on the temporary yard set not less than the stack
Height of the tight encirclement and take effective coverage, the other
Ibid
Mixer, bucket mention
Elevator, belt conveyor
Machine, kiln head silo,
other
Mixed exhaust gas
Exhaust gas, feed waste gas,
Other particles
Organized
Electrostatic precipitator (indicating the number of electric field, such as th...
|