US$549.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GBZ31822-2015: Study report on the safety requirements of public service escalators and moving walks Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/Z 31822-2015 | English | 549 |
Add to Cart
|
5 days [Need to translate]
|
Study report on the safety requirements of public service escalators and moving walks
| Valid |
GB/Z 31822-2015
|
PDF similar to GBZ31822-2015
Basic data | Standard ID | GB/Z 31822-2015 (GB/Z31822-2015) | | Description (Translated English) | Study report on the safety requirements of public service escalators and moving walks | | Sector / Industry | National Standard | | Classification of Chinese Standard | Q78 | | Classification of International Standard | 91.140.90 | | Word Count Estimation | 26,229 | | Date of Issue | 2015-07-03 | | Date of Implementation | 2016-02-01 | | Quoted Standard | GB 5226.1-2008; GB/T 7024; GB/T 7826-2012; GB/T 15706-2012; GB 16899-2011; GB/T 20900-2007; GB/T 21562-2008; GB/T 31200-2014 | | Regulation (derived from) | National Standard Announcement 2015 No.22 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China | | Summary | This Standard specifies the contents of the consultations between the public transport type escalator and moving walkways owners and manufacturers as well as public transport type escalator and moving walkways safety design guidelines, selection and planning, safety requirements, and (or) protection measures, use the relevant requirements. This Standard takes into account the safety of the following persons: a) passengers; b) public transport type escalator and moving walkways outside (but in the immediate vicinity) of personnel; c) authorized personnel (including maintenance and inspection personnel). |
GBZ31822-2015: Study report on the safety requirements of public service escalators and moving walks ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Study report on the safety requirements of public service escalators and moving walks
ICS 91.140.90
Q78
People's Republic of China national standardization of technical guidance documents
Public transport type escalators and moving walkways
Safety Requirements Guidance Document
movingwalks
Posted on.2015-07-03
2016-02-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
China National Standardization Administration released
Directory
Preface Ⅰ
Introduction Ⅱ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 Consultations between owners and manufacturers of public transit escalators and moving walkways 3
4.1 General 3
4.2 use 3
4.3 use of time 3
4.4 load conditions 4
4.5 Applicable Public Transport System Design Specification 4
5 Guidelines for the Design of Safety of Public Transport Escalators and Moving Walkways 4
5.1 General 4
5.2 Design based on good engineering practice 5
6 Selection and planning of public transport-type escalators and travelators, safety requirements and/or safeguards and use 6
6.1 General 6
6.2 Selection and Planning 6
6.3 Safety Requirements and/or Protective Measures 6
6.3.1 Support structure (truss) and coamings 6
6.3.2 Steps and Pedals 6
6.3.3 Drive 7
6.3.4 armrest system 7
6.3.5 Entrance 7
6.4 Usage Information 8
Appendix A (informative) Example of determining if an escalator is part of a public transportation system 9
Appendix B (informative) Public transport system design requirements related to escalators and moving walkways 14
Appendix C (Informative) List of Design Standards for Public Transport Escalators and Moving Walkways 18
References 20
Foreword
This instructional document has been drafted in accordance with the rules given in GB/T 1.1-2009.
This guiding technical document is proposed and managed by the National Elevator Standardization Technical Committee (SAC/TC196).
This instructional technical document is drafted by Shanghai Mitsubishi Elevator Co., Ltd.
The guidance of technical documents to participate in the drafting unit. Jiangnan Jiajie Elevator Co., Ltd., China Building Research Institute of Building Mechanization
Research Branch, Otis Elevator (China) Investment Co., Ltd., Schindler (China) Elevator Co., Ltd., Hitachi Elevator (Guangzhou) Escalator Co., Ltd.
Division, KONE Elevator Co., Ltd., Xizi Otis Elevator Co., Ltd., Yongda Elevator Equipment (China) Co., Ltd., ThyssenKrupp Elevator
State) Co., Ltd., Toshiba Elevator (China) Co., Ltd., Guangdong Institute of Special Equipment Inspection, Shanghai Special Equipment Supervision and Inspection Technology Research
Institute, Shenzhen Special Equipment Safety Inspection Institute, Jiangsu Institute of Special Equipment Safety Supervision and Inspection Suzhou Branch, Giant KONE
Co., Ltd., Shanghai Jiaotong University, Conli Elevator Co., Ltd., Guangzhou Guangri Elevator Co., Ltd., Suzhou Dili Elevator Co., Ltd.
Secretary, Mitsubishi Elevator Co., Ltd., Shanghai Hyundai Elevator Manufacturing Co., Ltd., Ningbo Lilongwe Group Co., Ltd., Younde Elevator Limited
Company, Kunshan Tongyou Elevator Co., Senhe Elevator Co., Ltd.
The main drafters of this Guidance Document are Zhu Rong, Shen Yin, Zhang Zhi Yan, Chen Feng Wang, Chen Yan Ying, Gao Xiang, Liang Jiasheng, Shang Rui, Li Jun,
Zhang Tongbo, Li Haihong, Qu Chengcheng, Zhang Jie, Qin Yi Fen, Chen Jiang, Ye Liang, Gu Jiadong, Feng Hongjing, Zhang Lichun, Geng Peng, Tang Linzhong, Chen Dong,
Ni Weibo, Pengnian Jun, Wang Weiqiang, Wang Mingfu, Shen Jianxue.
Introduction
0.1 In the current national standard GB 16899-2011, public transport-type escalators and moving walkways refer to the following situations
An escalator and moving walkway.
a) is part of the public transport system including the exit and entrance points;
b) High-intensity use, ie about 140 hours of weekly operating time, and 100% of braking load at any 3-hour interval
Duration of not less than 0.5h.
The public transportation system is an organic whole composed of various modes of public transport such as civil aviation, railways, waterway shipping, subways, light railways and public transport buses,
Has become an indispensable means of travel for people's daily life in modern society and generally requires long-term, almost continuous operation. As public transportation
The system components of escalators and moving walkways need to meet the functional requirements of the public transportation system to which they belong.
0.2 By definition, public transport-type escalators and moving walkways are escalators and autoworks that are used under certain conditions
Road, the main features of its conditions of use is long-term, almost continuous operation and high-intensity use, including "high-intensity use" also includes
Characteristics of the conditions of use of crowds that may occur near public transport-type escalators and moving walkways, especially at the entrances and exits. due to
There are significant differences between different public transport systems, for example, the large differences in traffic flow between urban subway stations and civil airports,
There are also significant differences in loading conditions between public transport type escalators and moving walkways, so public transport escalators and automatic
The needs of sidewalks are also different.
There are many factors affecting the traffic flow in public transport systems, including land planning (for example, the degree of maturity of the relevant area development, etc.)
Policies (eg fare adjustments, etc.), operational service levels (eg departure intervals, etc.), and operational coordination between various modes of transport
In addition, the expected traffic volume of the public transport system needs to be considered. The traffic volume of the public transport system is determined by the public transport project
And various parts of the construction scale, operating mode, an important basis.
0.3 GB 16899-2011 in the provisions of H.2, for public transport type escalators and moving walkways, manufacturers and owners should be based on actual
Traffic Flow Determines load conditions and additional safety functions.
According to traffic flow to determine the load conditions and additional safety features, for the owners is to traffic flow into load conditions and additional safety
Functions and other public transportation type escalators and moving walkways on the product requirements for public transport escalators and moving walkways to create
Business is to determine the product design input related content.
In addition to traffic flow, the factors that affect the functional and performance requirements of public transport-type escalators and moving walkways also include those applicable
Laws, regulations, standards, codes, environmental conditions (eg air temperature at public transport type escalators and moving walkways, air
Relative humidity, pollution levels, etc.), civil engineering issues, and specific requirements for specific public transportation system projects.
For special operating conditions (eg operation in open air, high altitude operation, public transport escalators and automatic people
Sidewalks for emergency exits, etc.), design guidelines, parts, materials, and instructions for use that conform to these particular operating conditions are required.
0.4 Design, manufacture, install and ultimately deliver public transportation escalators to meet all requirements based on product design input requirements
And moving walkways are the product realization process. This process involves quality control in design and development, procurement, production, monitoring and measurement
Therefore, manufacturers need to have a good quality management system. In addition, according to the product features, operating conditions and other maintenance plans developed,
Maintenance processes are carried out for repairs and are also intended for public transport escalators and travelators to meet expected expectations over their expected useful lives
Basic conditions.
Note The relevant requirements of quality management system see GB/T 19001. Escalators and moving walks maintenance specifications see GB/T 18775.
0.5 Public transportations Escalators and moving walkways where venues (eg. Railway stations) often carry heavy luggage
However, the use of escalators and moving walkways to carry bulky luggage can easily lead to danger. For these people, using the elevator is better traffic
the way. The management of these places should set the appropriate position to prohibit the use of escalators and moving walkways to transport heavy luggage
Signs, it is recommended to use the elevator instructions and elevator location guide signs, guide these people to use the elevator.
Some public transport-type escalators and moving walkways where the place (for example. Metro station) staff intensive, in the event of a sudden incident
May affect the safe operation of public transport type escalators and moving walks, or even secondary accidents, which are governed by the management of these places
The unit formulates contingency plans to effectively prevent and control possible accidents.
Note The relevant requirements of contingency plans see GB/T 29639.
0.6 This document is based on the definition of public transport-type escalators and travelators and GB 16899-2011 of the relevant provisions of the owners
And the contents of the consultation between the manufacturers conducted a study and GB 16899-2011 on the basis of the relevant provisions of the public transport given from
Escalators and moving walkways Corresponding safety design guidelines, selection and planning, safety requirements and/or protective measures and their use
Additional requirements.
Public transport type escalators and moving walkways
Safety Requirements Guidance Document
1 Scope
This guidance is given in the technical document for consultation between owners and manufacturers of public transport escalators and moving walkways
Safety Guidelines, Selection and Planning, Safety Requirements and/or Protective Measures, Use of Common Traffic-type Escalators and Moving Walkways
Related requirements.
This guidance document considers the safety of the following persons.
a) passenger
b) persons on public transport type escalators and outside of moving walks (but in close proximity);
c) Authorized personnel (including maintenance and inspection staff).
This guidance does not apply to technical documents.
a) safety during transport, installation, repair and dismantling of public transport type escalators and moving walkways;
b) Spiral public transport escalators;
c) Accelerated public transport type moving walkways.
However, this guidance document can be used as a guideline.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
Mechanical and electrical safety - Mechanical electrical equipment - Part 1. General specifications
GB/T 7024 elevators, escalators, moving walkways terminology
GB/T 7826-2012 System Reliability Analysis Techniques Failure Modes and Effects Analysis (FMEA) Procedures
GB/T 15706-2012 General rules for the design of machinery safety risk assessment and risk reduction
Safety precautions for the manufacture and installation of escalators and travelators GB 16899-2011
GB/T 20900-2007 elevators, escalators and moving walkways risk assessment and reduction methods
GB/T 21562-2008 rail transit reliability, availability, maintainability and safety specifications and examples
GB/T 31200-2014 Passenger elevators, escalators and moving walkways with graphical symbols and guidelines
3 Terms and definitions
GB/T 7024, GB 16899-2011 defined and the following terms and definitions apply to this document.
3.1
Public transport system publictransportsystem
By a variety of modes of public transport (for example, civil aviation, railways, waterway transport, subway, light rail, bus, etc.) composed of organic.
Remark GB/T 5655-1985, definition 1.3.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GBZ31822-2015_English be delivered?Answer: Upon your order, we will start to translate GBZ31822-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GBZ31822-2015_English with my colleagues?Answer: Yes. The purchased PDF of GBZ31822-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|